Direct simultaneous electrochemical determination of hydroquinone and catechol at a poly(glutamic acid) modified glassy carbon electrode

被引:0
|
作者
Wang, Liang [1 ]
Huang, Pengfei [1 ,2 ]
Bai, Junyue [1 ,2 ]
Wang, Hongjing [1 ]
Zhang, Liying [1 ]
Zhao, Yuqing [1 ]
机构
[1] Dalian Natl Univ, Coll Life Sci, Dalian 116600, Peoples R China
[2] Dalian Univ Technol, Sch Environm & Biol Sci & Technol, Dalian 116024, Peoples R China
来源
关键词
chemically modified electrode; glutamic acid; hydroquinone; catechol; electrochemical determination;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A simply and high selectively electrochemical method for simultaneous determination of hydroquinone (HQ) and catechol (CC) has been developed at a glassy carbon electrode modified with electropolymerized films of glutamic acid (p-Glu). This p-Glu modified electrode is used to simultaneous electrochemical determination of HQ and CC and shows an excellent electrocatalytical effect on the oxidation of HQ and CC by cyclic voltammetry (CV) in 0.1 M acetate buffer solution (pH 4.5). In differential pulse voltammetric (DPV) measurements, the p-Glu modified electrode could separate the oxidation peak potentials of HQ and CC present in binary mixtures by about 102 mV though the bare electrode gave a single broad response. A successful elimination of the fouling effect by the oxidized product of HQ on the response of CC has been achieved at the p-Pen modified electrode. The determination limit of HQ in the presence of 0.1 M CC was 1.0 x 10(-6) M and the determination limit of CC in the presence of 0.1 M HQ was 8.0 x 10(-7) M. The proposed method has been applied to simultaneous determination of HQ and CC in a water sample with simplicity and high selectivity.
引用
收藏
页码:123 / 132
页数:10
相关论文
共 50 条
  • [21] Simultaneous determination of catechol and hydroquinone based on poly (diallyldimethylammonium chloride) functionalized graphene-modified glassy carbon electrode
    Letao Wang
    Yan Zhang
    Yongling Du
    Daban Lu
    Yuzhen Zhang
    Chunming Wang
    Journal of Solid State Electrochemistry, 2012, 16 : 1323 - 1331
  • [22] Simultaneous determination of hydroquinone and catechol at PASA/MWNTs composite film modified glassy carbon electrode
    Zhao, Dong-Ming
    Zhang, Xiu-Hua
    Feng, Li-Jun
    Jia, Li
    Wang, Sheng-Fu
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 74 (01) : 317 - 321
  • [23] A glassy carbon electrode modified with cerium phosphate nanotubes for the simultaneous determination of hydroquinone, catechol and resorcinol
    Zhen Li
    Yuhua Yue
    Yanjun Hao
    Shun Feng
    Xianli Zhou
    Microchimica Acta, 2018, 185
  • [24] Simultaneous Determination of Catechol and Hydroquinone at a Carbon Nanotubes Modified Electrode
    Yang Shao-Ming
    Wei Zhi-Peng
    Hu Guang-Hui
    Jiang Dan
    Huang Ai-Hua
    Zheng Long-Zhen
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2010, 31 (02): : 264 - 268
  • [25] Simultaneous determination of catechol and hydroquinone based on poly (diallyldimethylammonium chloride) functionalized graphene-modified glassy carbon electrode
    Wang, Letao
    Zhang, Yan
    Du, Yongling
    Lu, Daban
    Zhang, Yuzhen
    Wang, Chunming
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (04) : 1323 - 1331
  • [26] Determination of hydroquinone and catechol at a poly(Arginine acid) modified electrode
    Yue Hua, A.
    Huang, Jin Zhan
    Song, Zong Rong
    Zhang, Ying
    Song, Li
    Sensors and Transducers, 2014, 175 (07): : 1 - 5
  • [27] Simultaneous and selective electrochemical determination of hydroquinone, catechol and resorcinol at poly(1,5-diaminonaphthalene)/glassy carbon-modified electrode in different media
    Hassan, Khalid Mahmoud
    Hathoot, Abla Ahmed
    Oura, Mohamed Fathi Abo
    Azzem, Magdi Abdel
    RSC ADVANCES, 2018, 8 (12): : 6346 - 6355
  • [28] Covalent modification of a glassy carbon electrode with penicillamine for simultaneous determination of hydroquinone and catechol
    Liang Wang
    Peng Fei Huang
    Jun Yue Bai
    Hong Jing Wang
    Li Ying Zhang
    Yu Qing Zhao
    Microchimica Acta, 2007, 158 : 151 - 157
  • [29] Covalent modification of a glassy carbon electrode with penicillamine for simultaneous determination of hydroquinone and catechol
    Wang, Liang
    Huang, Peng Fei
    Bai, Jun Yue
    Wang, Hong Jing
    Zhang, Li Ying
    Zhao, Yu Qing
    MICROCHIMICA ACTA, 2007, 158 (1-2) : 151 - 157
  • [30] Simultaneous Determination of Catechol and Hydroquinone Using Nickel Nanoparticles\Poly-4-Nitroaniline Nanocomposite Modified Glassy Carbon Electrode
    Ben Ali Hassine, Chedia
    Kahri, Hamza
    Barhoumi, Houcine
    IEEE SENSORS JOURNAL, 2021, 21 (17) : 18864 - 18870