The effect of femoral component rotation on the kinematics of the tibiofemoral and patellofemoral joints after total knee arthroplasty

被引:83
|
作者
Merican, A. M. [2 ,3 ]
Ghosh, K. M. [1 ,4 ]
Iranpour, F. [2 ]
Deehan, D. J. [4 ]
Amis, Andrew A. [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Mech Engn, London SW7 2AZ, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Orthopaed Surg, London SW7 2AZ, England
[3] Univ Malaya, Med Ctr, Dept Orthopaed Surg, Kuala Lumpur, Malaysia
[4] Newcastle Univ Hosp, Dept Orthopaed Surg, Newcastle Upon Tyne, Tyne & Wear, England
关键词
TKA; Femoral component rotation; Knee kinematics; Patellar tracking; PATELLAR TRACKING; PIVOT SHIFT; IN-VITRO; ALIGNMENT; DISPLACEMENT; MECHANISM; POSITION; PATTERN; GROOVE; AXIS;
D O I
10.1007/s00167-011-1499-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Complications after total knee arthroplasty (TKA) often involve the patellofemoral joint, and problems with patellar maltracking or lateral instability have sometimes been addressed by external rotation of the femoral component. This work sought to measure the changes of knee kinematics caused by TKA and then to optimise the restoration of both the patellofemoral and tibiofemoral joint kinematics, by variation of femoral component internal-external rotation. Methods The kinematics of the patella and tibia were measured in eight cadaveric knees during active extension motion. This was repeated with the knee intact, with a Genesis II TKA in the standard position (3A degrees of external rotation) and with the femoral component at +/- 5A degrees rotation from there. Results Both patellar and tibial motions were significantly different from normal with the standard TKA rotation, with 3A degrees tibial abduction at 90A degrees flexion and reversal of the screw-home from 5A degrees external rotation to 6A degrees internal rotation. The patella was shifted medially 6 mm in flexion and tilted 7A degrees more laterally near extension. Femoral rotation to address one abnormality caused increased abnormality in other degrees of freedom. Internal and then external rotation of 5A degrees caused tibial abduction and then adduction of 5A degrees at 90A degrees flexion. These femoral rotations also caused increased patellar lateral tilt of 4A degrees with femoral external rotation and decreased tilt by 4A degrees with internal rotation. Thus, correction of tibial abduction in flexion, by external rotation of the femoral component, worsened the patellar lateral tilt near extension. Conclusions It was concluded that femoral rotation alone could not restore all aspects of both patellar and tibial kinematics to normal with this specific implant. The clinical relevance of this is that it appears to be inadvisable to reposition the femoral component, in an attempt to improve patellar tracking, if that repositioning may then cause abnormal tibiofemoral kinematics. Further, the pattern of patellar tracking, with the type of TKA used in this study, could not be adjusted to normal by femoral component rotation.
引用
收藏
页码:1479 / 1487
页数:9
相关论文
共 50 条
  • [31] Correlation Between Rotation of the Femoral Component and Early Passive Flexion After Total Knee Arthroplasty
    Classen, T.
    Wegner, A.
    Mueller, R. -D
    von Knoch, M.
    PHYSIKALISCHE MEDIZIN REHABILITATIONSMEDIZIN KURORTMEDIZIN, 2011, 21 (01) : 41 - 44
  • [32] Reproducibility of measurement of femoral component rotation after total knee arthroplasty using computer tomography
    Suter, Thomas
    Zanetti, Marco
    Schmid, Marius
    Romero, Jose
    JOURNAL OF ARTHROPLASTY, 2006, 21 (05): : 744 - 748
  • [33] THE EFFECT OF FEMORAL COMPONENT POSITION ON PATELLAR TRACKING AFTER TOTAL KNEE ARTHROPLASTY
    RHOADS, DD
    NOBLE, PC
    REUBEN, JD
    MAHONEY, OM
    TULLOS, HS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (260) : 43 - 51
  • [34] Component design affecting patellofemoral complications after total knee arthroplasty
    Theiss, SM
    Kitziger, KJ
    Lotke, PS
    Lotke, PA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (326) : 183 - 187
  • [35] Magnetic resonance imaging of in vivo patellofemoral kinematics after total knee arthroplasty
    Carpenter, R. Dana
    Brilhault, Jean
    Majumdar, Sharmila
    Ries, Michael D.
    KNEE, 2009, 16 (05): : 332 - 336
  • [36] Effect of Femoral Component Design on Patellofemoral Crepitance and Patella Clunk Syndrome After Posterior-Stabilized Total Knee Arthroplasty
    Frye, Benjamin M.
    Floyd, Mark W.
    Pham, Dahn C.
    Feldman, John J.
    Hamlin, Brian R.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 1166 - 1170
  • [37] Component rotation and anterior knee pain after total knee arthroplasty
    Barrack, RL
    Schrader, T
    Bertot, AJ
    Wolfe, MW
    Myers, L
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (392) : 46 - 55
  • [38] Tibiofemoral articulation and axial tibial rotation of the knee after a cruciate retaining total knee arthroplasty
    Li, Guoan
    Zhou, Chaochao
    Li, Sophia
    Yu, Jia
    Foster, Timothy
    Bedair, Hany
    KNEE SURGERY & RELATED RESEARCH, 2024, 36 (01)
  • [39] Tibiofemoral Dislocation After Total Knee Arthroplasty
    Jethanandani, Rishabh G.
    Maloney, William J.
    Huddleston, James I.
    Goodman, Stuart B.
    Amanatullah, Derek F.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (10): : 2282 - 2285
  • [40] The Ranawat Award Paper - Optimizing femoral component rotation in total knee arthroplasty
    Miller, MC
    Berger, RA
    Petrella, AJ
    Karmas, A
    Rubash, HE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (392) : 38 - 45