High-Resolution Gamma Spectrometry of a Plutonium Bearing Waste Drum With High-Energy Reaction-Induced Gamma Rays

被引:3
|
作者
Bottau, V. [1 ]
Tondut, L. [2 ]
Allinei, P. -G. [1 ]
Perot, B. [1 ]
Eleon, C. [1 ]
Carasco, C. [1 ]
De Stefano, R. [1 ]
Faussier, G. [2 ]
机构
[1] French Alternat Energies & Atom Energy Commiss, Nucl Energy Div, DTN, SMTA,Nucl Measurement Lab, F-13108 St Paul Les Durance, France
[2] DT E MN EXP, Orano Business Unit Recycling, F-50440 La Hague, France
关键词
Gamma-ray spectrometry; high purity germanium detector (HPGe); plastic scintillators; plutonium dioxide; radioactive waste; NUCLEAR-DATA SHEETS; PULSE-SHAPE DISCRIMINATION; PLASTIC SCINTILLATORS; RADIOACTIVE-WASTE; LIGHT-NUCLEI; PERFORMANCE;
D O I
10.1109/TNS.2019.2959079
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the framework of the radioactive waste drum characterization using neutron coincidence counting, the Nuclear Measurement Laboratory of French Alternative Energies and Atomic Energy Commission (CEA) Cadarache is studying plastic scintillators as an alternative to ideal but costly He-3 gas proportional counters. Plastic scintillators are at least five times cheaper for the same detection efficiency, and in addition, they detect fast neutrons three orders of magnitude more quickly than He-3 detectors. However, they are sensitive to gamma rays with no pulse shape discrimination abilities for large detection volumes, which implies the necessity to identify precisely gamma background sources that may affect the useful signal. This article presents a detailed analysis of the gamma-ray spectrum of a radioactive waste drum containing glove box filters contaminated by plutonium dioxide. Classical gamma emissions following alpha and beta disintegrations are identified, and also those accompanying inelastic scattering (n, n') or radiative capture (n, gamma) reactions in the whole waste drum, and (alpha, n) or (alpha, p) reactions in the filtration media, which can lead to neutron-gamma coincidences parasitizing useful coincidences from plutonium spontaneous fissions.
引用
收藏
页码:575 / 584
页数:10
相关论文
共 50 条
  • [21] NEW POLARIMETER FOR HIGH-ENERGY GAMMA-RAYS
    IWATA, Y
    ENDO, I
    TOBIYAMA, M
    KOBAYASHI, T
    ISOBE, A
    NISHIZURU, T
    YOSHIDA, K
    MUTO, M
    EMURA, T
    NAGATA, K
    NAGATA, Y
    BABA, K
    ASAI, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 336 (1-2): : 146 - 149
  • [22] A SCINTILLATION SPECTROMETER FOR HIGH-ENERGY GAMMA-RAYS
    JOHANSSON, SAE
    PHILOSOPHICAL MAGAZINE, 1952, 43 (337): : 249 - 256
  • [23] HIGH-ENERGY GAMMA-RAYS FROM POLARS
    BARRETT, P
    SCHLEGEL, E
    DEJAGER, OC
    CHANMUGAM, G
    ASTROPHYSICAL JOURNAL, 1995, 450 (01): : 334 - 338
  • [24] High-energy gamma rays at Hiroshima and Nagasaki - Response
    Straume, T
    HEALTH PHYSICS, 1996, 71 (01): : 95 - 95
  • [25] HIGH-ENERGY DIFFUSE CELESTIAL GAMMA-RAYS
    FICHTEL, CE
    THOMPSON, DJ
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (04): : 582 - 582
  • [26] Quartic collimator design for high-energy gamma rays
    Furey, John
    Morgan, Cliff
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 629 (01): : 202 - 205
  • [27] HIGH-ENERGY GAMMA-RAYS FROM VELA
    FICHTEL, CE
    BIGNAMI, GF
    KNIFFEN, DA
    OGELMAN, HB
    THOMPSON, DJ
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (04): : 656 - 656
  • [28] EXPERIMENTS WITH MONOENERGETIC HIGH-ENERGY GAMMA-RAYS
    MOREH, R
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1982, (62): : 575 - 589
  • [29] A SCINTILLATION SPECTROMETER FOR HIGH-ENERGY GAMMA-RAYS
    JOHANSSON, SAE
    NATURE, 1950, 166 (4227) : 794 - 795
  • [30] Fundamental Physics With Cosmic High-Energy Gamma Rays
    De Angelis, Alessandro
    HIGH ENERGY GAMMA-RAY ASTRONOMY, 2017, 1792