Cuffless Blood Pressure Estimation Using Pressure Pulse Wave Signals

被引:53
|
作者
Liu, Zeng-Ding [1 ]
Liu, Ji-Kui [2 ]
Wen, Bo [2 ]
He, Qing-Yun [1 ]
Li, Ye [1 ,3 ]
Miao, Fen [1 ,3 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, Shenzhen 518055, Peoples R China
[2] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen 518055, Peoples R China
[3] Chinese Acad Sci HICAS, Shenzhen Inst Adv Technol, Key Lab Hlth Informat, Shenzhen 518055, Peoples R China
基金
中国国家自然科学基金;
关键词
cuffless blood pressure; piezoelectric sensor; pressure pulse waveform; pulse transit time; multiparameter fusion; ARTERIAL TONOMETRY; DICROTIC NOTCH; PEAK DETECTION; ARRIVAL-TIME; LESS; PHOTOPLETHYSMOGRAPHY; DEVICE; FORM; PPG;
D O I
10.3390/s18124227
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pulse transit time (PTT) has received considerable attention for noninvasive cuffless blood pressure measurement. However, this approach is inconvenient to deploy in wearable devices because two sensors are required for collecting two-channel physiological signals, such as electrocardiogram and pulse wave signals. In this study, we investigated the pressure pulse wave (PPW) signals collected from one piezoelectric-induced sensor located at a single site for cuffless blood pressure estimation. Twenty-one features were extracted from PPW that collected from the radial artery, and then a linear regression method was used to develop blood pressure estimation models by using the extracted PPW features. Sixty-five middle-aged and elderly participants were recruited to evaluate the performance of the constructed blood pressure estimation models, with oscillometric technique-based blood pressure as a reference. The experimental results indicated that the mean +/- standard deviation errors for the estimated systolic blood pressure and diastolic blood pressure were 0.70 +/- 7.78 mmHg and 0.83 +/- 5.45 mmHg, which achieved a decrease of 1.33 +/- 0.37 mmHg in systolic blood pressure and 1.14 +/- 0.20 mmHg in diastolic blood pressure, compared with the conventional PTT-based method. The proposed model also demonstrated a high level of robustness in a maximum 60-day follow-up study. These results indicated that PPW obtained from the piezoelectric sensor has great feasibility for cuffless blood pressure estimation, and could serve as a promising method in home healthcare settings.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] The Wavelet Transform of Pulse Wave and Electrocardiogram Improves Accuracy of Blood Pressure Estimation in Cuffless Blood Pressure Measurement
    Yamanaka, Syunsuke
    Morikawa, Koji
    Yamamura, Osamu
    Morita, Hiroshi
    Huh, Ji Young
    CIRCULATION, 2016, 134
  • [2] The Wavelet Transform of Pulse Wave and Electrocardiogram Improves Accuracy of Blood Pressure Estimation in Cuffless Blood Pressure Measurement
    Yamanaka, Syunsuke
    Morikawa, Koji
    Yamamura, Osamu
    Morita, Hiroshi
    Huh, Ji Young
    CIRCULATION, 2016, 134
  • [3] Cuffless Blood Pressure Estimation from the Carotid Pulse Arrival Time using Continuous Wave Radar
    Buxi, Dilpreet
    Redoute, Jean-Michel
    Yuce, Mehmet Rasit
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 5704 - 5707
  • [4] Estimation of Cuffless Systolic and Diastolic Blood Pressure Using Pulse Transient Time
    Mehrabbeik, Mahtab
    Rashidi, Saeid
    2019 5TH IRANIAN CONFERENCE ON SIGNAL PROCESSING AND INTELLIGENT SYSTEMS (ICSPIS 2019), 2019,
  • [5] Cuffless Blood Pressure Estimation Based on Monte Carlo Simulation Using Photoplethysmography Signals
    Haque, Chowdhury Azimul
    Kwon, Tae-Ho
    Kim, Ki-Doo
    SENSORS, 2022, 22 (03)
  • [6] Blood pressure estimation by using pulse wave sensor
    Suzuki, Arata
    Tsuji, Yoshiki
    Ue, Mizuki
    Ryu, Kazuteru
    Transactions of Japanese Society for Medical and Biological Engineering, 2014, 52
  • [7] Noninvasive Cuffless Blood Pressure Estimation Using Pulse Transit Time and Impedance Plethysmography
    Toan Huu Huynh
    Jafari, Roozbeh
    Chung, Wan-Young
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (04) : 967 - 976
  • [8] Cuffless blood pressure estimation using only a smartphone
    Kenta Matsumura
    Peter Rolfe
    Sogo Toda
    Takehiro Yamakoshi
    Scientific Reports, 8
  • [9] Cuffless blood pressure estimation using only a smartphone
    Matsumura, Kenta
    Rolfe, Peter
    Toda, Sogo
    Yamakoshi, Takehiro
    SCIENTIFIC REPORTS, 2018, 8
  • [10] Cuffless Continuous Blood Pressure Estimation From Pulse Morphology of Photoplethysmograms
    Yan, Wen-Rong
    Peng, Rong-Chao
    Zhang, Yuan-Ting
    Ho, Derek
    IEEE ACCESS, 2019, 7 : 141970 - 141977