Measurement of Whole Blood Coagulation Time by Laser Speckle Pattern Correlation

被引:3
|
作者
Liushnevskaya, Yu D. [1 ]
Gubarev, F. A. [1 ]
Li, L. [2 ]
Nosarev, A., V [3 ]
Gusakova, V. S. [3 ]
机构
[1] Natl Res Tomsk Polytech Univ, Tomsk, Russia
[2] Liaoning Tech Univ, Fuxin, Peoples R China
[3] Siberian State Med Univ, Minist Hlth Russian Federat, Tomsk, Russia
来源
关键词
Speckle;
D O I
10.1007/s10527-020-10018-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present here the results obtained by correlation analysis of digital speckle patterns to assess coagulation time in citrated whole blood. The spread of coagulation time values in experiments was no more than 25% for an essentially healthy cohort of laboratory animals. Studies of normal and pathological plasma showed that the method is able to detect pathological hemostasis. The ability to create a new universal optical coagulometer analyzing citrated and native blood, as well as whole blood, is discussed. Estimation of citrated blood clotting time is an intermediate stage in developing a test for native blood.
引用
收藏
页码:262 / 266
页数:5
相关论文
共 50 条
  • [41] THE EFFECT OF CORTICOTROPHIN, CORTISONE, AND PREDNISONE ON WHOLE BLOOD COAGULATION TIME
    DREYFUSS, F
    MENCZEL, J
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1958, 51 (04): : 530 - 538
  • [42] A COAGULOCHRONOMETER - A DEVICE FOR AUTOMATICALLY RECORDING THE COAGULATION TIME OF WHOLE BLOOD
    BARKER, NW
    PROCEEDINGS OF THE STAFF MEETINGS OF THE MAYO CLINIC, 1948, 23 (10): : 230 - 233
  • [43] High-resolution laser speckle correlation for displacement and strain measurement
    Feiel, R. (feiel@emt.tu-graz.ac.at), 2000, Optical Society of America (OSA) (39):
  • [44] A study on laser speckle correlation method applied in triangulation displacement measurement
    Shen, Lei
    Li, Dinggen
    Luo, Feng
    OPTIK, 2013, 124 (20): : 4544 - 4548
  • [45] Measurement of displacement in the micrometer range using speckle pattern correlation in multimode fibers
    Lomer, M.
    Abascal, J.
    Castrellon-Uribe, J.
    Lopez-Higuera, J. M.
    FIFTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS, 2013, 8794
  • [46] Time-resolved vibration measurement with temporal speckle pattern interferometry
    Kauffmann, Jochen
    Tiziani, Hans J.
    APPLIED OPTICS, 2006, 45 (26) : 6682 - 6688
  • [47] Mechanisms of laser-induced thermal coagulation of whole blood in vitro
    Pfefer, TJ
    Choi, B
    Vargas, G
    McNally, KM
    Welch, AJ
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS IX, PROCEEDINGS OF, 1999, 3590 : 20 - 31
  • [48] OPTIMAL SAMPLING RESOLUTION AND RANGE OF MEASUREMENT IN DIGITAL SPECKLE CORRELATION .1. LASER SPECKLE METHOD
    CHEN, DJ
    CHIANG, FP
    PROCEEDINGS OF THE 1989 SEM SPRING CONFERENCE ON EXPERIMENTAL MECHANICS, 1989, : 133 - 138
  • [49] A SIMPLE AND RAPID MEASUREMENT OF THE PROTHROMBIN TIME (PT) FOR OUTPATIENTS BY A NOVEL WHOLE-BLOOD COAGULATION MONITOR SYSTEM
    YANO, Y
    SHIBA, E
    KAWASAKI, T
    SAKON, M
    KAMBAYASHI, J
    MORI, T
    THROMBOSIS AND HAEMOSTASIS, 1991, 65 (06) : 1221 - 1221
  • [50] COAGULATION AND FIBRINOLYSIS IN PREGNANCY STUDIED BY THE WHOLE-BLOOD CLOTTING TIME AND THE DILUTE WHOLE-BLOOD CLOT LYSIS TIME
    OMSJO, IH
    OIAN, P
    MALTAU, JM
    OSTERUD, B
    THROMBOSIS AND HAEMOSTASIS, 1985, 54 (01) : 272 - 272