Power Quality Improvement In Low Voltage Distribution System Using Dynamic Voltage Restorer (DVR)

被引:0
|
作者
Omar, Rosli [1 ]
Rahim, N. A. [2 ]
机构
[1] Univ Telaiikal Melaka, Fac Elect, Ayer Keroh, Malacca, Malaysia
[2] Univ Malaya, Fac Engn, UMPEDAC, Kuala Lumpur, Malaysia
关键词
Dynamic Voltage Restorer; d-q-o controller; voltage swells; distribution system; sensitive load;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper discusses the mitigation of power quality disturbance in low voltage distribution system due to voltage swells using one of the powerful power custom devices namely Dynamic Voltage Restorer (DVR). The DVR normally installed between the source voltage and critical or sensitive load. The new configuration of DVR has been proposed using improved d-q-o controller technique.. The simulations are performed using Matlab/Simulink's SimPower Toolbox. The proposal is then implemented using 5KVA DVR experimental setup. The simulation and experimental results demonstrate the effective dynamic performance of the proposed configuration.
引用
收藏
页码:408 / +
页数:2
相关论文
共 50 条
  • [41] Application of Dynamic Voltage Restorer for Power Quality Improvement in Induction furnace
    Saggu, Tejinder Singh
    Singh, Lakhwinder
    2016 IEEE CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (CCECE), 2016,
  • [42] A waveform synthesis technique for voltage sag compensation using dynamic voltage restorer (DVR)
    Immanuel, Vijayan
    Yankanchi, Gurunath
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 951 - +
  • [43] Power Quality Improvement of Grid Connected Wind Farms through Voltage Restoration Using Dynamic Voltage Restorer
    Jerin, Rini Ann A.
    Palanisamy, K.
    Umashankar, S.
    Thirumoorthy, A. D.
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2016, 6 (01): : 53 - 60
  • [44] Effective Controller Design for the Dynamic Voltage Restorer (DVR) for Voltage Sag Mitigation in Distribution Utilities
    Xu, Lin
    Han, Yang
    ELEKTROTEHNISKI VESTNIK-ELECTROCHEMICAL REVIEW, 2011, 78 (05): : 304 - 311
  • [45] Low Voltage Ride-Through Capability Improvement of Wind Power Generation Using Dynamic Voltage Restorer
    Hasegawa, Naohiro
    Kumano, Teruiiisa
    RECENT ADVANCES IN ENERGY AND ENVIRONMENT, 2010, : 166 - +
  • [46] Dynamic voltage restorer (DVR) enhancement in power quality mitigation with an adverse impact of unsymmetrical faults
    Farooqi, Awais
    Othman, Muhammad Murtadha
    Radzi, Mohd Amran Mohd
    Musirin, Ismail
    Noor, Siti Zaliha Mohammad
    Abidin, Izham Zainal
    ENERGY REPORTS, 2022, 8 : 871 - 882
  • [47] Voltage sag mitigation in an Indian distribution system using dynamic voltage restorer
    Patel, Debasis
    Goswami, Arup Kumar
    Singh, Santosh Kumar
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 71 : 231 - 241
  • [48] Control and testing of a dynamic voltage restorer (DVR) at medium voltage level
    Nielsen, JG
    Newman, M
    Nielsen, H
    Blaabjerg, F
    PESC'03: 2003 IEEE 34TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 1248 - 1253
  • [49] Review of dynamic voltage restorer for power quality
    Praveen, J
    Muni, BP
    Venkateshwarlu, S
    Makthal, HV
    IECON 2004 - 30TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOL. 1, 2004, : 749 - 754
  • [50] Fast Repetitive Controller Based Low-Voltage Dynamic Voltage Restorer for Voltage-Quality Issues in Distribution System
    Guo, Suxuan
    IEEE PEDG 2010: THE 2ND INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS, 2010, : 988 - 992