In this paper different procedures are validated to diagnose and assess the severity degree of rotor faults in closed loop controlled induction machines. The possible diagnostic indexes are investigated through spectral analysis of manipulated and controlled variables. Common control schemes have been considered to evaluate the diagnostic robustness towards operating condition and regulator parameters. Voltage injection was considered as well as a possible tool for diagnostics by analyzing the amplitude of spectral lines arising in motor input current spectrum. Experimental results guide the selection of suitable analytical models for the faulty machine. The experiments are obtained with a DSP based Current Controlled Voltage Source Inverter (CCVSI) supplying a 1.5 kW induction machine in which three different rotors differing in asymmetry degree were used.
引用
收藏
页码:356 / 362
页数:7
相关论文
共 50 条
  • [31] Application of Nested topology of Multilevel inverter in closed loop control of induction motor drives
    Saha, Souvik
    Behera, Subrat
    Roy, Tapas
    Nayak, Byamakesh
    PROCEEDINGS OF THE 2017 IEEE SECOND INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND COMMUNICATION TECHNOLOGIES (ICECCT), 2017,
  • [32] Assessment of approaches for technical diagnostic of pump faults with induction motor as transducer
    Bold, Sebastian
    Urschel, Sven
    2020 23RD INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2020, : 810 - 815
  • [33] Diagnostic feature selection for efficient recognition of different faults of rotor bars in the induction machine
    Kurek, Jaroslaw
    Osowski, Stanislaw
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (01): : 121 - 123
  • [34] Quantitative broken rotor bar fault detection for closed-loop controlled induction motors
    Hou, Zhaowen
    Huang, Jin
    Liu, He
    Wang, Tong
    Zhao, Lihang
    IET ELECTRIC POWER APPLICATIONS, 2016, 10 (05) : 403 - 410
  • [35] A Nonintrusive Thermal Monitoring Method for Induction Motors Fed by Closed-Loop Inverter Drives
    Cheng, Siwei
    Du, Yi
    Restrepo, Jose A.
    Zhang, Pinjia
    Habetler, Thomas G.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (09) : 4122 - 4131
  • [36] Stator winding turn-fault detection for closed-loop induction motor drives
    Tallam, RM
    Habetler, TG
    Harley, RG
    CONFERENCE RECORD OF THE 2002 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2002, : 1553 - 1557
  • [37] To Issue of Designing Scalar Closed-Loop Controllers for Frequency Controlled Induction Motor Drives
    Vladimir, Polyakov
    Dmitry, Shcherbakov
    2018 17TH INTERNATIONAL URAL CONFERENCE ON AC ELECTRIC DRIVES (ACED), 2018,
  • [38] CONSTANT TORQUE CLOSED-LOOP ROTOR RESISTANCE CONTROLLER FOR DC DYNAMIC BRAKING OF A WOUND ROTOR INDUCTION-MOTOR
    NAYAR, CV
    FEHR, RR
    PERAHIA, J
    THOMAS, FP
    VASU, E
    ELECTRIC MACHINES AND POWER SYSTEMS, 1994, 22 (01): : 61 - 76
  • [39] CLOSED-LOOP ROTOR RESISTANCE CONTROL METHOD FOR IMPROVED dc DYNAMIC BRAKING OF WOUND ROTOR INDUCTION MOTOR.
    Gupta, J.R.P.
    Singh, Bhim
    Singh, B.P.
    IEEE Transactions on Industry Applications, 1985, IA-21 (01) : 235 - 240
  • [40] A CLOSED-LOOP ROTOR RESISTANCE CONTROL METHOD FOR IMPROVED DC DYNAMIC BRAKING OF WOUND ROTOR INDUCTION-MOTOR
    GUPTA, JRP
    SINGH, B
    SINGH, BP
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1985, 21 (01) : 235 - 240