Tumor-liver contrast and subjective tumor conspicuity of respiratory-triggered T2-weighted fast spin-echo sequence compared with T2-weighted gradient recalled-echo sequence for ferucarbotran-enhanced magnetic resonance imaging of hepatic malignant tumors

被引:9
|
作者
Ishiyama, Koichi [1 ]
Hashimoto, Manabu [1 ]
Izumi, Jun-ichi [1 ]
Watarai, Jiro [1 ]
Shibata, Satoshi
Sato, Tsutomu [2 ]
Yamamoto, Yuzo [2 ]
机构
[1] Akita Univ, Sch Med, Dept Radiol, Akita 010, Japan
[2] Akita Univ, Sch Med, Dept Surg, Akita 010, Japan
关键词
liver neoplasm; iron; magnetic resonance (MR); contrast media; ferucarbotran;
D O I
10.1002/jmri.21399
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare respiratory-triggered T2-weighted fast spin-echo (RTT2W-FSE) and gradient T2*-weighted recalled-echo (T2*W-GRE) images for visualization of malignant hepatic tumors using ferucarbotran-enhanced magnetic resonance (MR) imaging. Materials and Methods: Ferucarbotran-enhanced RTT2W-FSE and breath-hold long-TE 2D-fast spoiled gradient recalled acquisition in the steady state (FSPGR) images as T2*W-GRE were used to evaluate 128 malignant hepatic tumors (77 metastases, 37 hepatocellular carcinomas, 14 other) in 62 patients. Tumor-to-liver contrast (TLC) was quantitatively compared using the paired Student's t-test, and the score of lesion conspicuity was qualitatively compared using Wilcoxon's signed rank test. Results: The mean TLC of RTT2W-FSE was significantly higher than that of FSPGR (1.10 +/- 0.82 vs. 2.54 +/- 1.42) in all malignant tumors. The score of lesion conspicuity of RTT2W-FSE was significantly higher than that of FSPGR, (4.84 +/- 0.52 vs. 4.52 +/- 0.99) in all malignant tumors. Conclusion: For ferucarbotran-enhanced MR imaging, compared to FSPGR images, RTT2W-FSE images provide greater TLC and subjective conspicuity for malignant tumors.
引用
收藏
页码:1322 / 1326
页数:5
相关论文
共 50 条
  • [21] Detection of focal hepatic lesions with MR imaging: Prospective comparison of T2-weighted fast spin-echo with and without fat suppression, T2-weighted breath-hold fast spin-echo, and gadolinium chelate-enhanced 3D gradient-recalled imaging
    Soyer, P
    deGivry, SC
    Gueye, C
    Lenormand, S
    Somveille, E
    Scherrer, A
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (05) : 1115 - 1121
  • [22] Detection of focal fiver lesions in unenhanced and ferucarbotran-enhanced magnetic resonance imaging: a comparison of T2-weighted breath-hold and respiratory-triggered sequences
    Rief, Matthias
    Wagner, Moritz
    Franiel, Tobias
    Bresan, Viola
    Taupitz, Matthias
    Klessen, Christian
    Hamm, Bernd
    Asbach, Patrick
    MAGNETIC RESONANCE IMAGING, 2009, 27 (09) : 1223 - 1229
  • [23] The value of respiratory triggered T2-weighted turbo spin-echo imaging of the liver using a phased array coil
    Namimoto, T
    Yamashita, Y
    Mitsuzaki, K
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03): : 655 - 662
  • [24] Imaging of the degenerative spine using a sagittal T2-weighted DIXON turbo spin-echo sequence
    Sollmann, Nico
    Moench, Sebastian
    Riederer, Isabelle
    Zimmer, Claus
    Baum, Thomas
    Kirschke, Jan S.
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 131
  • [25] T2-weighted MRI of rectosigmoid carcinoma: Comparison of respiratory-triggered fast spin-echo, breathhold fast-recovery fast spin-echo, and breathhold single-shot fast spin-echo sequences
    Yamashita, Shuhei
    Masui, Takayuki
    Katayama, Motoyuki
    Sato, Kimihiko
    Yoshizawa, Nobuko
    Seo, Hidekazu
    Sakahara, Harumi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (03) : 511 - 516
  • [26] MR imaging of acoustic neuroma with high resolution fast spin echo T2-weighted sequence
    Soulie, D
    Cordoliani, YS
    Vignaud, J
    Cosnard, G
    EUROPEAN JOURNAL OF RADIOLOGY, 1997, 24 (01) : 61 - 65
  • [27] Manually respiratory-triggered single-shot fast spin-echo:: a non-breath-hold T2-weighted method for liver lesion
    O'Riordan, E
    Haider, MA
    O'Malley, ME
    Khalili, K
    Ibach, K
    Lockwood, GA
    Bahadorani, B
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2003, 54 (05): : 289 - 295
  • [28] MR-IMAGING OF HEAD AND NECK TUMORS - COMPARISON OF T1-WEIGHTED CONTRAST-ENHANCED FAT-SUPPRESSED IMAGES WITH CONVENTIONAL T2-WEIGHTED AND FAST SPIN-ECHO T2-WEIGHTED IMAGES
    ROSS, MR
    SCHOMER, DF
    CHAPPELL, P
    ENZMANN, DR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (01) : 173 - 178
  • [29] Liver T2-weighted MR imaging: Assessment of a three-dimensional fast spin-echo with extended echo train acquisition sequence at 1.5 Tesla
    Denoiseux, Celine Cotereau
    Boulay-Coletta, Isabelle
    Nakache, Jean-Pierre
    Claude, Isabelle Dufour
    Zins, Marc
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (02) : 336 - 343
  • [30] Focal liver lesions: Breathhold gradient- and spin-echo T2-weighted imaging for detection and characterization
    Yoshikawa, T
    Mitchell, DG
    Hirota, S
    Ohno, Y
    Yoshigi, J
    Maeda, T
    Fujii, M
    Sugimura, K
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (04) : 520 - 528