Development of a rapid, 96-well alkaline based differential DNA extraction method for sexual assault evidence

被引:21
|
作者
Hudlow, William R. [1 ]
Buoncristiani, Martin R. [1 ]
机构
[1] Justice Jan Bashinski DNA Lab, Calif Dept, Richmond, CA 94804 USA
关键词
Forensic sciences; Alkaline lysis; Sodium hydroxide; DNA typing; Differential extraction; Sexual assault evidence; FORENSIC STAINS; COTTON SWABS; WHOLE-BLOOD; SPERM; RECOVERY;
D O I
10.1016/j.fsigen.2010.12.015
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
We present a rapid alkaline lysis procedure for the extraction of DNA from sexual assault evidence that generates purified sperm fraction extracts that yield STR typing results similar to those obtained from the traditional organic/dithiothreitol differential extraction. Specifically, a sodium hydroxide based differential extraction method has been developed in a single-tube format and further optimized in a 96-well format. The method yields purified extracts from a small sample set (similar to 2-6 swabs) in approximately 2 h and from a larger sample set (up to 96 swabs) in approximately 4 h. While conventional differential extraction methods require vigorous sample manipulation to remove the spermatozoa from the substrate, the method described here exploits the propensity of sperm to adhere to a substrate and does not require any manipulation of the substrate after it is sampled. For swabs, sample handling is minimized by employing a process where the tip of the swab, including the shaft, is transferred to the appropriate vessel eliminating the need for potentially hazardous scalpels to separate the swab material from the shaft. The absence of multiple handling steps allows the process to be semi-automated, however the procedure as described here does not require use of a robotic system. This method may provide forensic laboratories a cost-effective tool for the eradication of backlogs of sexual assault evidence, and more timely service to their client agencies. In addition, we have demonstrated that a modification of the procedure can be used to retrieve residual sperm-cell DNA from previously extracted swabs. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [41] A rapid and simple method to quantify per- and polyfluoroalkyl substances (PFAS) in plasma and serum using 96-well plates
    Da Silva, Bianca Ferreira
    Ahmadireskety, Atiye
    Aristizabal-Henao, Juan J.
    Bowden, John A.
    METHODSX, 2020, 7
  • [42] Rapid purification of fluorescent dye-labeled products in a 96-well format for high-throughput automated DNA sequencing
    Krakowski, K
    Bunville, J
    Seto, J
    Baskin, D
    Seto, D
    NUCLEIC ACIDS RESEARCH, 1995, 23 (23) : 4930 - 4931
  • [43] Development of a 96-well based assay for kinetic determination of catalase enzymatic-activity in biological samples
    Grilo, Luis F.
    Martins, Joao D.
    Cavallaro, Chiara H.
    Nathanielsz, Peter W.
    Oliveira, Paulo J.
    Pereira, Susana P.
    TOXICOLOGY IN VITRO, 2020, 69
  • [44] Resazurin-based 96-well plate microdilution method for the determination of minimum inhibitory concentration of biosurfactants
    Elshikh, Mohamed
    Ahmed, Syed
    Funston, Scott
    Dunlop, Paul
    McGaw, Mark
    Marchant, Roger
    Banat, Ibrahim M.
    BIOTECHNOLOGY LETTERS, 2016, 38 (06) : 1015 - 1019
  • [45] Development of a novel bead-based 96-well filtration plate competitive immunoassay for the detection of Gentamycin
    Ho, Tien Yu Jessica
    Chan, Chia-Chung
    Chan, KingHo
    Wang, Yu Chieh
    Lin, Jing-Tang
    Chang, Cheng-Ming
    Chen, Chien-Sheng
    BIOSENSORS & BIOELECTRONICS, 2013, 49 : 126 - 132
  • [46] Resazurin-based 96-well plate microdilution method for the determination of minimum inhibitory concentration of biosurfactants
    Mohamed Elshikh
    Syed Ahmed
    Scott Funston
    Paul Dunlop
    Mark McGaw
    Roger Marchant
    Ibrahim M. Banat
    Biotechnology Letters, 2016, 38 : 1015 - 1019
  • [47] Development of a cellulose-based 96-well plate vertical flow pull-down assay
    Cheng, Hoi Lok
    Jia, Huan
    Lim, Sing Mei
    Ng, Say Yong
    Kongsuphol, Patthara
    McBee, Megan E.
    Sikes, Hadley D.
    ANALYTICAL METHODS, 2023, 15 (28) : 3483 - 3489
  • [48] 96-well polycarbonate-based microfluidic titer plate for high-throughput purification of DNA and RNA
    Witek, Magorzata A.
    Hupert, Mateusz L.
    Park, Daniel S. -W.
    Fears, Kirby
    Murphy, Michael C.
    Soper, Steven A.
    ANALYTICAL CHEMISTRY, 2008, 80 (09) : 3483 - 3491
  • [49] Development and validation of a rapid HPLC method for the determination of cefdinir in beagle dog plasma integrated with an automatic on-line solid-phase extraction following protein precipitation in the 96-well plate format
    Li, Ji
    Wang, Li
    Chen, Zhao
    Xie, Rui
    Li, You
    Hang, Taijun
    Fan, Guorong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 895 : 83 - 88
  • [50] Development of a high-throughput method based on thin-film microextraction using a 96-well plate system with a cork coating for the extraction of emerging contaminants in river water samples
    Mores, Lucas
    Dias, Adriana Neves
    Carasek, Eduardo
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (03) : 697 - 703