Modified air-assisted descemetorhexis for Descemet-stripping automated endothelial keratoplasty

被引:30
|
作者
Mehta, Jodhbir S. [1 ,2 ]
Hantera, Mohammed M. [1 ]
Tan, Donald T. [1 ,2 ,3 ]
机构
[1] Singapore Natl Eye Ctr, Singapore 168751, Singapore
[2] Singapore Eye Res Inst, Singapore, Singapore
[3] Natl Univ Singapore, Dept Ophthalmol, Singapore 117548, Singapore
来源
关键词
D O I
10.1016/j.jcrs.2008.01.037
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Descemet-stripping automated endothelial keratoplasty (DSAEK) is an alternative to penetrating keratoplasty for the treatment of corneal endothelial disease that involves stripping diseased Descemet membrane (DM) from the recipient. Descemet membrane stripping is currently performed with a generic balanced salt solution (BSS) or an ophthalmic viscosurgical device in the anterior chamber, but limitations of these techniques include poor visualization of DM and difficulty maneuvering loose DM. We describe a simple modified technique to perform descemetorhexis under air that improves visualization, even in cloudy corneas, and aids in control of DM because of the enhanced surface tension from the air-fluid interface on the posterior corneal surface.
引用
收藏
页码:889 / 891
页数:3
相关论文
共 50 条
  • [31] Technique to F mark Descemet-stripping endothelial keratoplasty graft
    Viola, Pietro
    Soldati, Sandro
    Altafini, Romeo
    Cian, Roberto
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (10): : 1743 - 1744
  • [32] Descemet-Stripping Endothelial Keratoplasty Following Penetrating Keratoplasty at a Tertiary Care Center
    Lee, B. S.
    Stark, W. J.
    Bartsch, J. D.
    Jun, A. S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [33] Descemet Membrane Endothelial Keratoplasty Versus Descemet Stripping Automated Endothelial Keratoplasty and Penetrating Keratoplasty
    Woo, Jyh-Haur
    Ang, Marcus
    Htoon, Hla Myint
    Tan, Donald
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 207 : 288 - 303
  • [34] Intrascleral fibrin glue intraocular lens fixation combined with Descemet-stripping automated endothelial keratoplasty or penetrating keratoplasty
    Sinha, Rajesh
    Shekhar, Himanshu
    Sharma, Namrata
    Tandon, Radhika
    Titiyal, Jeewan S.
    Vajpayee, Rasik B.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (07): : 1240 - 1245
  • [35] Development of a nomogram to achieve ultrathin donor corneal disks for Descemet-stripping automated endothelial keratoplasty
    Villarrubia, Alberto
    Cano-Ortiz, Antonio
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (01): : 146 - 151
  • [36] Descemet-stripping automated endothelial keratoplasty for vitrectomized cases with traumatic aniridia and aphakic bullous keratopathy
    Eguchi, Hiroshi
    Miyamoto, Tatsuro
    Hotta, Fumika
    Tomida, Machiko
    Inoue, Masayuki
    Mitamura, Yoshinori
    CLINICAL OPHTHALMOLOGY, 2012, 6 : 1513 - 1518
  • [37] Graft profile and thickness as a function of cut transition speed in Descemet-stripping automated endothelial keratoplasty
    Bhogal, Maninder S.
    Allan, Bruce D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (04): : 690 - 695
  • [38] Early Results of Descemet-Stripping and Automated Endothelial Keratoplasty (DSAEK) in Patients With Glaucoma Drainage Devices
    Riaz, Kamran M.
    Sugar, Joel
    Tu, Elmer Y.
    Edward, Deepak P.
    Wilensky, Jacob T.
    Namavari, Abed
    Djalilian, Ali R.
    CORNEA, 2009, 28 (09) : 959 - 962
  • [39] Descemet stripping automated endothelial keratoplasty for microcornea
    Hiroshi Toshida
    Toshihiko Ohta
    Akira Murakami
    Akira Kobayashi
    Kazuhisa Sugiyama
    Japanese Journal of Ophthalmology, 2012, 56 : 436 - 440
  • [40] Descemet stripping automated endothelial keratoplasty for microcornea
    Toshida, Hiroshi
    Ohta, Toshihiko
    Murakami, Akira
    Kobayashi, Akira
    Sugiyama, Kazuhisa
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2012, 56 (05) : 436 - 440