Computer Navigation for Revision Total Hip Arthroplasty Reduces Dislocation Rates

被引:4
|
作者
Sharma, Abhinav K. [1 ]
Cizmic, Zlatan [2 ]
Carroll, Kaitlin M. [3 ]
Jerabek, Seth A. [3 ]
Paprosky, Wayne G. [4 ]
Sculco, Peter K. [3 ]
Gonzalez Della Valle, Alejandro [3 ]
Schwarzkopf, Ran [5 ]
Mayman, David J. [3 ]
Vigdorchik, Jonathan M. [3 ]
机构
[1] Univ Calif Irvine, Dept Orthopaed Surg, Sch Med, 101 City Dr South,Pavil 3,Bldg 29A, Orange, CA 92868 USA
[2] Ascens Providence Hosp Southfield Campus, Dept Orthopaed Surg, 16001 W Nine Mile Rd, Southfield, MI 48075 USA
[3] Hosp Special Surg, Dept Orthoped Surg Adult Reconstruct & Joint Repl, 535 East 70th St, New York, NY 10021 USA
[4] Rush Presbyterian St Lukes Med Ctr, Sect Adult Joint Reconstruct, Dept Orthopaed Surg, 1653 W Congress Pkwy, Chicago, IL 60612 USA
[5] NYU Langone Hlth, Div Adult Reconstruct, Dept Orthoped Surg, 301 E 17th St, New York, NY 10010 USA
关键词
Total hip arthroplasty; Revision total hip arthroplasty; Computer navigation; Dislocation; Technology; RISK-FACTORS; ACETABULAR COMPONENT; UNITED-STATES; LIMB LENGTH; EPIDEMIOLOGY; REPLACEMENT; ORIENTATION; PLACEMENT; ACCURACY;
D O I
10.1007/s43465-022-00606-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Computer navigation in total hip arthroplasty (THA) offers potential for more accurate placement of acetabular components, avoiding impingement, edge loading, and dislocation, all of which can necessitate revision THA (rTHA). Therefore, the use of computer navigation may be particularly beneficial in patients undergoing rTHA. The purpose of this study was to determine if the use of computer-assisted hip navigation reduces the rate of dislocation in patients undergoing rTHA. Methods A retrospective review of 72 patients undergoing computer-navigated rTHA between February 2016 and May 2017 was performed. Demographics, indications for revision, type of procedure performed, and incidence of postoperative dislocation were collected for all patients. Clinical follow-up was recorded at 3 months, 1 year and 2 years. Results All 72 patients (48% female; 52% male) were included for analysis. The mean age was 70.4 +/- 11.2 years and mean BMI was 26.4 +/- 5.2 kg/m(2). 22 of 72 patients (31%) required a rTHA procedure due to instability resulting in dislocation. At 3 months, 1 year, and 2 years, there were no dislocations (0%). There was a significant reduction in dislocation rate after computer-navigated rTHA (0%) relative to that following primary THA in the same patient cohort (31%; p < 0.05). Conclusion Our study demonstrates a significant reduction in dislocation rate following rTHA with computer navigation. Although the cause of postoperative dislocation is often multifactorial, the use of computer navigation may help to curtail femoral and acetabular malalignment in rTHA.
引用
收藏
页码:1061 / 1065
页数:5
相关论文
共 50 条
  • [21] The value of computed tomography based navigation in revision total hip arthroplasty
    Kuroda, Kazunari
    Kabata, Tamon
    Maeda, Toru
    Kajino, Yoshitomo
    Watanabe, Shin
    Iwai, Shintaro
    Kenji, Fujita
    Hasegawa, Kazuhiro
    Inoue, Daisuke
    Tsuchiya, Hiroyuki
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (04) : 711 - 716
  • [22] The value of computed tomography based navigation in revision total hip arthroplasty
    Kazunari Kuroda
    Tamon Kabata
    Toru Maeda
    Yoshitomo Kajino
    Shin Watanabe
    Shintaro Iwai
    Fujita Kenji
    Kazuhiro Hasegawa
    Daisuke Inoue
    Hiroyuki Tsuchiya
    International Orthopaedics, 2014, 38 : 711 - 716
  • [23] Revision total hip arthroplasty
    Lakstein, D.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2010, 61 (01) : 51 - 65
  • [24] Revision total hip arthroplasty
    Sporer, SM
    Paprosky, WG
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (417) : 203 - 209
  • [25] Conversion total hip arthroplasty: Primary or revision total hip arthroplasty
    Schwarzkopf, Ran
    Baghoolizadeh, Mahta
    WORLD JOURNAL OF ORTHOPEDICS, 2015, 6 (10): : 750 - 753
  • [26] Tranexamic Acid Reduces Blood Transfusions in Revision Total Hip Arthroplasty
    Park, Kwan J.
    Couch, Cory G.
    Edwards, Paul K.
    Siegel, Eric R.
    Mears, Simon C.
    Barnes, C. Lowry
    JOURNAL OF ARTHROPLASTY, 2016, 31 (12): : 2850 - +
  • [27] Early Revision Rates of Total Hip Arthroplasty Using the Intellijoint HIP Computer Navigation System: A Study From the Australian National Joint Replacement Registry of 1911 Procedures
    Lourens, Ernest C.
    Kurmis, Andrew P.
    Holder, Carl
    de Steiger, Richard N.
    ARTHROPLASTY TODAY, 2022, 18 : 149 - 156
  • [28] Re-dislocation after revision total hip arthroplasty for recurrent dislocation: a multicentre study
    Yoshimoto, Kensei
    Nakashima, Yasuharu
    Aota, Shigeo
    Kaneuji, Ayumi
    Fukui, Kiyokazu
    Hirakawa, Kazuo
    Nakura, Nariaki
    Kinoshita, Koichi
    Naito, Masatoshi
    Iwamoto, Yukihide
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (02) : 253 - 258
  • [29] Re-dislocation after revision total hip arthroplasty for recurrent dislocation: a multicentre study
    Kensei Yoshimoto
    Yasuharu Nakashima
    Shigeo Aota
    Ayumi Kaneuji
    Kiyokazu Fukui
    Kazuo Hirakawa
    Nariaki Nakura
    Koichi Kinoshita
    Masatoshi Naito
    Yukihide Iwamoto
    International Orthopaedics, 2017, 41 : 253 - 258
  • [30] Prediction model for an early revision for dislocation after primary total hip arthroplasty
    Pakarinen, Oskari
    Karsikas, Mari
    Reito, Aleksi
    Lainiala, Olli
    Neuvonen, Perttu
    Eskelinen, Antti
    PLOS ONE, 2022, 17 (09):