Detecting 5-morpholino-3-amino-2-oxazolidone residue in food with label-free electrochemical impedimetric immunosensor

被引:39
|
作者
Jin, Wenjie [2 ]
Yang, Gongjun [1 ]
Wu, Liping [3 ]
Wang, Qianqian [2 ]
Shao, Hongxia [2 ]
Qin, Aijian [2 ]
Yu, Bing [4 ]
Li, Dongming [4 ]
Cai, Baoliang [4 ]
机构
[1] China Pharmaceut Univ, Sch Pharm, Nanjing 210009, Peoples R China
[2] Yangzhou Univ, Coll Vet Med, Key Lab Poultry Prevent Med, Minist Educ, Yangzhou 225002, Peoples R China
[3] Yangzhou Univ, Coll Chem & Chem Engn, Yangzhou 225002, Peoples R China
[4] Jiangsu Entry Exit Inspect & Quarantine Bur, Dept Supervis Food Safety, Nanjing 210000, Peoples R China
基金
中国国家自然科学基金;
关键词
Immunosensor; 5-Morpholino-3-amino-2-oxazolidone; Residue; Food; Electrochemical impedance spectroscopy; SENSITIVE DETECTION; CAPACITIVE IMMUNOSENSOR; IMPEDANCE IMMUNOSENSOR; NITROFURAN METABOLITE; CYCLIC VOLTAMMETRY; GOLD; NANOPARTICLES; IMMOBILIZATION; ELECTRODE; 3-AMINO-2-OXAZOLIDINONE;
D O I
10.1016/j.foodcont.2011.03.017
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
This paper reported a novel label-free electrochemical impedimetric immunosensor for sensitive detection of metabolite of furaltadone, 5-morpholino-3-amino-2-oxazolidone (denoted as AMOZ), based on monoclonal antibody against AMOZ (denoted as AMOZ McAb) immobilized on gold electrode modified with 1,4-benzenedithiol and gold nanoparticle self-assembled layers. The sensitive steps of surface modification have been characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The immunoreaction between AMOZ and AMOZ McAb directly triggered a signal via electrochemical impedance spectroscopy measurement. Under the optimized conditions, the relative change in impedance was proportional to the logarithmic value of AMOZ concentrations in the range of 1.0 to 1.0 x 10(6) ng/mL (r = 0.9991) with the detection limit of 1.0 ng/mL The advantages of the immunosensor are exhibited in its high sensitivity, wide linear range and better stability. The proposed impedimetric immunosensor was successfully applied to the determination of AMOZ in animal derived food with excellent recoveries. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1609 / 1616
页数:8
相关论文
共 50 条
  • [41] Label-Free Electrochemical Immunosensor Made with Tree-like Gold Dendrites for Monitoring 25-Hydroxyvitamin D3 Metabolite
    Martins, Thiago S.
    Bott-Neto, Jose L.
    Machado, Sergio A. S.
    Oliveira, Osvaldo N.
    ACS APPLIED MATERIALS & INTERFACES, 2022, 14 (27) : 31455 - 31462
  • [42] Enhanced performance of label-free electrochemical immunosensor for carbohydrate antigen 15-3 based on catalytic activity of cobalt sulfide/graphene nanocomposite
    Khoshroo, Alireza
    Mazloum-Ardakani, Mohammad
    Forat-Yazdi, Mohammad
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 580 - 587
  • [43] Label-Free Electrochemical Immunosensor Made with Tree-like Gold Dendrites for Monitoring 25-Hydroxyvitamin D3 Metabolite
    Martins, Thiago S.
    Bott-Neto, José L.
    MacHado, Sergio A. S.
    Oliveira, Osvaldo N.
    ACS Applied Materials and Interfaces, 2022, 14 (27): : 31455 - 31462
  • [44] Label-free electrochemical immunosensor based on flower-like Ag/MoS2/rGO nanocomposites for ultrasensitive detection of carcinoembryonic antigen
    Wang, Yaoguang
    Wang, Yulan
    Wu, Dan
    Ma, Hongmin
    Zhang, Yong
    Fan, Dawei
    Pang, Xuehui
    Du, Bin
    Wei, Qin
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 125 - 132
  • [45] Label-free electrochemical immunosensor for insulin detection by high-efficiency synergy strategy of Pd NPs@3D MoSx towards H2O2
    Gao, Zengqiang
    Li, Yueyun
    Zhang, Chunyan
    Zhang, Shuan
    Li, Faying
    Wang, Ping
    Wang, Huan
    Wei, Qin
    BIOSENSORS & BIOELECTRONICS, 2019, 126 : 108 - 114
  • [46] Label-free electrochemical biosensors based on 3,3′;5,5′-, tetramethylbenzidine responsive isoporous silica-micelle membrane
    Sun, Qinqin
    Yan, Fei
    Su, Bin
    BIOSENSORS & BIOELECTRONICS, 2018, 105 : 129 - 136
  • [47] Electrochemical immunosensor with N-doped graphene-modified electrode for label-free detection of the breast cancer biomarker CA 15-3
    Li, He
    He, Jing
    Li, Songjun
    Turner, Anthony P. F.
    BIOSENSORS & BIOELECTRONICS, 2013, 43 : 25 - 29
  • [48] Label-free electrochemical immunosensor based on biocompatible nanoporous Fe3O4 and biotin-streptavidin system for sensitive detection of zearalenone
    Wang, Yaoguang
    Zhao, Guanhui
    Wang, Huan
    Zhang, Yong
    Zhang, Nuo
    Wei, Dong
    Feng, Rui
    Wei, Qin
    ANALYST, 2020, 145 (04) : 1368 - 1375
  • [49] Flower-like WSe2 used as bio-matrix in ultrasensitive label-free electrochemical immunosensor for human immunoglobulin G determination
    Zhu, Leijing
    Ma, Jing
    Jin, Danli
    Zhang, Yongjian
    Wu, Siyu
    Xu, Ajing
    Gu, Yingying
    An, Yarui
    Miao, Yuqing
    ANALYTICAL SCIENCES, 2023, 39 (08) : 1391 - 1403
  • [50] Flower-like WSe2 used as bio-matrix in ultrasensitive label-free electrochemical immunosensor for human immunoglobulin G determination
    Leijing Zhu
    Jing Ma
    Danli Jin
    Yongjian Zhang
    Siyu Wu
    Ajing Xu
    Yingying Gu
    Yarui An
    Yuqing Miao
    Analytical Sciences, 2023, 39 : 1391 - 1403