Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT:: MRI validation and comparison of the Emory Cardiac Tool Box with QGS and 4D-MSPECT

被引:0
|
作者
Schaefer, WM
Lipke, CSA
Standke, D
Kühl, HP
Nowak, B
Kaiser, HJ
Koch, KC
Buell, U
机构
[1] Rhein Westfal TH Aachen, Univ Hosp, Dept Nucl Med, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Univ Hosp, Med Clin Cardiol 1, D-52074 Aachen, Germany
关键词
gated (99m)Tc-MIBI SPECT; Emory Cardiac Tool Box; 4D-MSPECT; Quantitative Gated SPECT; cardiovascular MRI; left ventricular volumes; ejection fraction;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The goal of this study was to validate the accuracy of the Emory Cardiac Tool Box (ECTB) in assessing left ventricular end-diastolic or end-systolic volume (EDV, ESV) and ejection fraction (LVEF) from gated (99m)Tc-methoxyisobutylisonitrile ((99m)Tc-MIBI) SPECT using cardiac MRI (cMRI) as a reference. Furthermore, software-specific characteristics of ECTB were analyzed in comparison with 4D-MSPECT and Quantitative Gated SPECT (QGS) results (all relative to cMRI). Methods: Seventy patients with suspected or known coronary artery disease were examined using gated 99mTc-MIBI SPECT (8 gates/cardiac cycle) 60 min after tracer injection at rest. EDV, ESV, and LVEF were calculated from gated 99mTc-MIBI SPECT using ECTB, 4D-MSPECT, and QGS. Directly before or after gated SPECT, cMRI (20 gates/cardiac cycle) was performed as a reference. EDV, ESV, and LVEF were calculated using Simpson's rule. Results: Correlation between results of gated 99mTc-MIBI SPECT and cMRI was high for EDV (R = 0.90 [ECTB], R = 0.88 [4D-MSPECT], R = 0.92 [QGS]), ESV (R = 0.94 [ECTB], R = 0.96 [4D-MSPECT], R = 0.96 [QGS]), and LVEF (R = 0.85 [ECTB], P = 0.87 [4D-MSPECT], R = 0.89 [QGS]). EDV (ECTB) did not differ significantly from cMRI, whereas 4D-MSPECT and QGS underestimated EDV significantly compared with cMRI (mean +/- SD: 131 +/- 43 mL [ECTB], 127 +/- 42 mL [4D-MSPECT], 120 +/- 38 mL [QGS], 137 +/- 36 mL [cMRI]). For ESV, only ECTB yielded values that were significantly lower than cMRI. For LVEF, ECTB and 4D-MSPECT values did not differ significantly from cMRI, whereas QGS values were significantly lower than cMRI (mean SD: 62.7% +/- 13.7% [ECTB], 59.0% +/- 12.7% [4D-M-SPECT], 53.2% +/- 11.5% [QGS], 60.6% +/- 13.9% [cMRI]). Conclusion: EDV, ESV, and LVEF as determined by ECTB, 4D-MSPECT, and QGS from gated 99mTc-MIBI SPECT agree over a wide range of clinically relevant values with cMR1. Nevertheless, any algorithm-inherent over- or underestimation of volumes and LVEF should be accounted for and an interchangeable use of different software packages should be avoided.
引用
收藏
页码:1256 / 1263
页数:8
相关论文
共 48 条
  • [21] Comparison of 99mTc tetrofosmin gated SPECT measurements of left ventricular volumes and ejection fraction with MRI over a wide range of values
    Thorley, PJ
    Plein, S
    Bloomer, TN
    Ridgway, JP
    Sivananthan, UM
    NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (07) : 763 - 769
  • [22] Comparison of Gated Blood Pool SPECT with cardiac ultrasound for quantification of left ventricular volumes and ejection fraction.
    Bugriy, M.
    Rogunova, N.
    Saidova, M.
    Sergienko, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S311 - S311
  • [23] Short-term reproducibility of parameters (endphasic left ventricular volumes, ejection fraction) estimated by QGS from gated-99mTc-Tetrofosmin SPECT.
    Schaefer, WM
    Block, S
    Namdar, T
    Nowak, B
    Koch, KC
    Vom Dahl, J
    Buell, U
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 166P - 166P
  • [24] Quantification of left ventricular volumes and ejection fraction from 16- and rebinned 8-frame gated 99mTc-tetrofosmin SPECT
    Schaefer, W. M.
    Kaiser, H-J.
    Kuehl, H.
    Koch, K-C.
    Nowak, B.
    Buell, U.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2007, 46 (01): : 22 - 28
  • [25] MRI validation of a widely available quantification routine for left ventricular volumes and ejection fraction from gated cardiac FDG PET.
    Schaefer, WM
    Lipke, CS
    Nowak, B
    Kaiser, HJ
    Kuehl, H
    Buell, U
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 85P - 85P
  • [26] Same day repeatability of left ventricular ejection fraction measured by 8-frame and 16-frame 99mTc-MIBI gated SPECT.
    Wrang, H.
    Roed, L.
    Lonborg-Jensen, H.
    Henriksen, O. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S400 - S400
  • [27] Left ventricular volumes and ejection fraction calculated from quantitative electrocardiographic-gated 99mTc-tetrofosmin myocardial SPECT
    Yoshioka, J
    Hasegawa, S
    Yamaguchi, H
    Tokita, N
    Paul, AK
    Mu, XL
    Maruyama, A
    Hori, M
    Nishimura, T
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (10) : 1693 - 1698
  • [28] LEFT-VENTRICULAR EJECTION FRACTION AND VOLUMES CALCULATED FROM DUAL GATED SPECT MYOCARDIAL IMAGING WITH TC-99(M)-MIBI
    KOURIS, K
    ABDELDAYEM, HM
    TAHA, B
    BALLANI, N
    HASSAN, IM
    CONSTANTINIDES, C
    NUCLEAR MEDICINE COMMUNICATIONS, 1992, 13 (09) : 648 - 655
  • [29] Gated 99mTc-MIBI single-photon emission computed tomography for the evaluation of left ventricular ejection fraction: comparison with three-dimensional echocardiography
    Piotr Lipiec
    Paulina Wejner-Mik
    Maria Krzemińska-Pakuła
    Jacek Kuśmierek
    Anna Płachcińska
    Remigiusz Szumiński
    Anna Kapusta
    Jarosław D. Kasprzak
    Annals of Nuclear Medicine, 2008, 22 : 723 - 726
  • [30] Gated 99mTc-MIBI single-photon emission computed tomography for the evaluation of left ventricular ejection fraction: comparison with three-dimensional echocardiography
    Lipiec, Piotr
    Wejner-Mik, Paulina
    Krzeminska-Pakula, Maria
    Kusmierek, Jacek
    Plachcinska, Anna
    Szuminski, Remigiusz
    Kapusta, Anna
    Kasprzak, Jaroslaw D.
    ANNALS OF NUCLEAR MEDICINE, 2008, 22 (08) : 723 - 726