Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT:: MRI validation and comparison of the Emory Cardiac Tool Box with QGS and 4D-MSPECT

被引:0
|
作者
Schaefer, WM
Lipke, CSA
Standke, D
Kühl, HP
Nowak, B
Kaiser, HJ
Koch, KC
Buell, U
机构
[1] Rhein Westfal TH Aachen, Univ Hosp, Dept Nucl Med, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Univ Hosp, Med Clin Cardiol 1, D-52074 Aachen, Germany
关键词
gated (99m)Tc-MIBI SPECT; Emory Cardiac Tool Box; 4D-MSPECT; Quantitative Gated SPECT; cardiovascular MRI; left ventricular volumes; ejection fraction;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The goal of this study was to validate the accuracy of the Emory Cardiac Tool Box (ECTB) in assessing left ventricular end-diastolic or end-systolic volume (EDV, ESV) and ejection fraction (LVEF) from gated (99m)Tc-methoxyisobutylisonitrile ((99m)Tc-MIBI) SPECT using cardiac MRI (cMRI) as a reference. Furthermore, software-specific characteristics of ECTB were analyzed in comparison with 4D-MSPECT and Quantitative Gated SPECT (QGS) results (all relative to cMRI). Methods: Seventy patients with suspected or known coronary artery disease were examined using gated 99mTc-MIBI SPECT (8 gates/cardiac cycle) 60 min after tracer injection at rest. EDV, ESV, and LVEF were calculated from gated 99mTc-MIBI SPECT using ECTB, 4D-MSPECT, and QGS. Directly before or after gated SPECT, cMRI (20 gates/cardiac cycle) was performed as a reference. EDV, ESV, and LVEF were calculated using Simpson's rule. Results: Correlation between results of gated 99mTc-MIBI SPECT and cMRI was high for EDV (R = 0.90 [ECTB], R = 0.88 [4D-MSPECT], R = 0.92 [QGS]), ESV (R = 0.94 [ECTB], R = 0.96 [4D-MSPECT], R = 0.96 [QGS]), and LVEF (R = 0.85 [ECTB], P = 0.87 [4D-MSPECT], R = 0.89 [QGS]). EDV (ECTB) did not differ significantly from cMRI, whereas 4D-MSPECT and QGS underestimated EDV significantly compared with cMRI (mean +/- SD: 131 +/- 43 mL [ECTB], 127 +/- 42 mL [4D-MSPECT], 120 +/- 38 mL [QGS], 137 +/- 36 mL [cMRI]). For ESV, only ECTB yielded values that were significantly lower than cMRI. For LVEF, ECTB and 4D-MSPECT values did not differ significantly from cMRI, whereas QGS values were significantly lower than cMRI (mean SD: 62.7% +/- 13.7% [ECTB], 59.0% +/- 12.7% [4D-M-SPECT], 53.2% +/- 11.5% [QGS], 60.6% +/- 13.9% [cMRI]). Conclusion: EDV, ESV, and LVEF as determined by ECTB, 4D-MSPECT, and QGS from gated 99mTc-MIBI SPECT agree over a wide range of clinically relevant values with cMR1. Nevertheless, any algorithm-inherent over- or underestimation of volumes and LVEF should be accounted for and an interchangeable use of different software packages should be avoided.
引用
收藏
页码:1256 / 1263
页数:8
相关论文
共 48 条
  • [1] Validation of QGS and 4D-MSPECT for quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT:: Comparison with MRI
    Schäfer, W
    Lipke, C
    Kühl, H
    Nowak, B
    Büll, U
    Cardio-Visions 2004: JUNGE EXZELLENZE IN DER KARDIOVASKULAREN FORSCHUNG, 2005, : 223 - 226
  • [2] Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPET:: comparison with cardiac magnetic resonance imaging
    Lipke, CSA
    Kühl, HP
    Nowak, B
    Kaiser, HJ
    Reinartz, P
    Koch, KC
    Buell, U
    Schaefer, WM
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (04) : 482 - 490
  • [3] Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPET: comparison with cardiac magnetic resonance imaging
    Claudia S. A. Lipke
    Harald P. Kühl
    Bernd Nowak
    Hans-Juergen Kaiser
    Patrick Reinartz
    Karl-Christian Koch
    Udalrich Buell
    Wolfgang M. Schaefer
    European Journal of Nuclear Medicine and Molecular Imaging, 2004, 31 : 482 - 490
  • [4] Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT:: validation of an elastic surface model approach in comparison to cardiac magnetic resonance imaging, 4D-MSPECT and QGS
    Stegger, Lars
    Lipke, Claudia S. A.
    Kies, Peter
    Nowak, Bernd
    Schober, Otmar
    Buell, Udalrich
    Schaefers, Michael
    Schaefer, Wolfgang M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (06) : 900 - 909
  • [5] Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: validation of an elastic surface model approach in comparison to cardiac magnetic resonance imaging, 4D-MSPECT and QGS
    Lars Stegger
    Claudia S. A. Lipke
    Peter Kies
    Bernd Nowak
    Otmar Schober
    Udalrich Buell
    Michael Schäfers
    Wolfgang M. Schaefer
    European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 900 - 909
  • [6] Validation of QGS and 4D-MSPECT for quantification of left ventricular volumes and ejection fraction from gated 18F-FDG PET:: Comparison with cardiac MRI
    Schaefer, WM
    Lipke, CSA
    Nowak, B
    Kaiser, HJ
    Reinartz, P
    Buecker, A
    Krombach, GA
    Buell, U
    Kühl, HP
    JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (01) : 74 - 79
  • [7] Comparison of 4D-MSPECT and QGS in quantification of left ventricular volumes and ejection fraction from 16-and rebinned 8-frame gated 99mTc-Tetrofosmin SPECT
    Schaefer, W. M.
    Krohn, T.
    Koch, K. C.
    Kaiser, H.
    Buell, U.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S119 - S119
  • [8] Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation of the exini heart software package
    Winz, Oliver H.
    Meyer, Philipp T.
    Knollmann, Daniela
    Lipke, Claudia S. A.
    Kuhl, Harald P.
    Oelve, Carola
    Schaefer, Wolfgang M.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2009, 29 (02) : 89 - 94
  • [9] Quantification of left ventricular volumes and ejection fraction for low-likehood CHD patients from gated SPECT: Comparison of QGS, ECToolbox and 4D-MSPECT
    Li, Jiajun
    He, Zuoxiang
    CARDIOLOGY, 2011, 120 : 61 - 62
  • [10] Comparison of QGS and 4d-mspect calculated left ventricular ejection fraction and volumes in patients with normal cardiac perfusion and function
    Bickci, N.
    Canbaz, F.
    Basoglu, T.
    Yapici, O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S234 - S234