Corrosion kinetics of iron thin film in deaerated phosphate solutions by an electrochemical quartz crystal microbalance

被引:0
|
作者
Seo, M [1 ]
Kurosaki, M [1 ]
机构
[1] Hokkaido Univ, Grad Sch Engn, Kita Ku, Sapporo, Hokkaido 060, Japan
来源
PROCEEDINGS OF THE SYMPOSIUM ON PASSIVITY AND ITS BREAKDOWN | 1998年 / 97卷 / 26期
关键词
D O I
暂无
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The corrosion rates of iron thin film in deaerated phosphate solutions were measured by an electrochemical quartz crystal microbalance as a function of solution pH or phosphorus concentration in solutions. The dependences of corrosion rate and corrosion potential on solution pH and phosphorus concentration have suggested that the corrosion mechanism changes in the vicinity of pH 5 and H2PO4- contributes more significantly to the corrosion processes of iran at pH 6.5 than at pH 3.0.
引用
收藏
页码:221 / 230
页数:6
相关论文
共 50 条
  • [31] Kinetics Study on Initial Growth Stage in Vapor Deposition of Organic Thin Film Using Quartz Crystal Microbalance
    Ito, Takaya
    Onoda, Shinya
    Kino, Masaaki
    Hagihara, Kiyoshi
    Kubono, Atsushi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2011, 50 (06)
  • [32] Application of quartz crystal microbalance to corrosion research
    Seo, Masahiro
    Zairyo to Kankyo/ Corrosion Engineering, 1999, 48 (10): : 610 - 620
  • [33] KINETICS OF ALUMINUM FILM OXIDATION MEASURED BY A MODIFIED QUARTZ-CRYSTAL MICROBALANCE
    MARTIN, M
    FROMM, E
    THIN SOLID FILMS, 1993, 236 (1-2) : 199 - 203
  • [34] Detection and kinetics of methylamine on chitosan film coated quartz crystal microbalance electrode
    Ayad, Mohamad M.
    Minisy, Islam M.
    PROGRESS IN ORGANIC COATINGS, 2016, 100 : 76 - 80
  • [35] Limitations of the use of the electrochemical quartz crystal microbalance in stripping analysis of lead(II) and cadmium(II) on a quartz crystal platinum electrode with a thin mercury film
    Andersen, NPR
    ANALYTICA CHIMICA ACTA, 1998, 368 (03) : 191 - 196
  • [36] A comparison of electrochemical methods and the rotating electrochemical quartz crystal microbalance for measuring hydrometallurgical reaction kinetics
    Jeffrey, MI
    Choo, WL
    Breuer, PL
    HYDROMETALLURGY, 2005, 79 (1-2) : 69 - 79
  • [37] Electrochemical Quartz Crystal Microbalance Technique in Sonoelectrochemistry
    Schneider, O.
    Martens, S.
    Argirusis, Chr.
    PHYSICAL, ELECTROANALYTICAL, AND BIOANALYTICAL ELECTROCHEMISTRY, 2010, 25 (28): : 69 - 80
  • [38] AN ELECTROCHEMICAL QUARTZ CRYSTAL MICROBALANCE STUDY OF POLYAZULENE
    ARBUCKLE, GA
    CHENG, RR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 204 : 138 - COLL
  • [39] Graphene oxide thin film coated quartz crystal microbalance for humidity detection
    Yao, Yao
    Chen, Xiangdong
    Guo, Huihui
    Wu, Zuquan
    APPLIED SURFACE SCIENCE, 2011, 257 (17) : 7778 - 7782
  • [40] On the accuracy of the quartz-crystal microbalance (QCM) in thin-film depositions
    Wajid, A
    SENSORS AND ACTUATORS A-PHYSICAL, 1997, 63 (01) : 41 - 46