A randomised comparison of two faecal immunochemical tests in population-based colorectal cancer screening

被引:33
|
作者
Grobbee, E. J. [1 ]
van der Vlugt, M. [2 ]
van Vuuren, A. J. [1 ]
Stroobants, A. K. [3 ]
Mundt, M. W. [4 ]
Spijker, W. J. [5 ]
Bongers, E. J. C. [6 ]
Kuipers, E. J.
Lansdorp-Vogelaar, I. [7 ]
Bossuyt, P. M. [8 ]
Dekker, E. [2 ]
Spaander, M. C. W. [1 ]
机构
[1] Erasmus Univ, Med Ctr, Dept Gastroenterol & Hepatol, Room Hs-312,Gravendijkwal 230, NL-3015 CE Rotterdam, Netherlands
[2] Acad Med Ctr Amsterdam, Dept Gastroenterol & Hepatol, Amsterdam, Netherlands
[3] Acad Med Ctr Amsterdam, Dept Clin Chem, Amsterdam, Netherlands
[4] Flevoziekenhuis Almere, Dept Gastroenterol & Hepatol, Almere, Netherlands
[5] Reg Org Populat Screening South West Netherlands, Rotterdam, Netherlands
[6] Fdn Populat Screening Mid West, Amsterdam, Netherlands
[7] Erasmus Univ, Med Ctr, Dept Publ Hlth, Rotterdam, Netherlands
[8] Univ Amsterdam, Acad Med Ctr, Dept Clin Epidemiol Biostat & Bioinformat, Amsterdam, Netherlands
关键词
OCCULT BLOOD-TESTS; 3; ROUNDS; PERFORMANCE; HEMOGLOBIN; TRENDS; YIELD; RISK;
D O I
10.1136/gutjnl-2016-311819
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objective Colorectal cancer screening programmes are implemented worldwide; many are based on faecal immunochemical testing (FIT). The aim of this study was to evaluate two frequently used FITs on participation, usability, positivity rate and diagnostic yield in population-based FIT screening. Design Comparison of two FITs was performed in a fourth round population-based FIT-screening cohort. Randomly selected individuals aged 50-74 were invited for FIT screening and were randomly allocated to receive an OC -Sensor (Eiken, Japan) or faecal occult blood (FOB)-Gold (Sentinel, Italy) test (March-December 2014). A cut-off of 10 mg haemoglobin (Hb)/g faeces (ie, 50 ng Hb/mL buffer for OC-Sensor and 59 ng Hb for FOB-Gold) was used for both FITs. Results In total, 19 291 eligible invitees were included (median age 61, IQR 57-67; 48% males): 9669 invitees received OC-Sensor and 9622 FOB-Gold; both tests were returned by 63% of invitees (p = 0.96). Tests were non-analysable in 0.7% of participants using OC-Sensor vs 2.0% using FOB-Gold (p < 0.001). Positivity rate was 7.9% for OC-Sensor, and 6.5% for FOB-Gold (p = 0.002). There was no significant difference in diagnostic yield of advanced neoplasia (1.4% for OC-Sensor vs 1.2% for FOB-Gold; p = 0.15) or positive predictive value (PPV; 31% vs 32%; p = 0.80). When comparing both tests at the same positivity rate instead of cut-off, they yielded similar PPV and detection rates. Conclusions The OC-Sensor and FOB-Gold were equally acceptable to a screening population. However, FOB-Gold was prone to more non-analysable tests. Comparison between FIT brands is usually done at the same Hb stool concentration. Our findings imply that for a fair comparison on diagnostic yield between FIT's positivity rate rather than Hb concentration should be used.
引用
收藏
页码:1975 / 1982
页数:8
相关论文
共 50 条
  • [41] COST COMPARISON OF FAECAL IMMUNOCHEMICAL TESTS TO CONVENTIONAL METHODS AS DIAGNOSTIC TOOL IN COLORECTAL CANCER
    Kearsey, Christopher
    Graham, Catherine
    Chako, Jerry
    Weatherburn, Rachael
    Kennedy, Sue
    Rooney, Paul
    GUT, 2021, 70 : A197 - A198
  • [42] PARTICIPATION AND PRACTICAL USE OF FECAL IMMUNOCHEMICAL TESTS IN COLORECTAL CANCER SCREENING: A COMPARISON OF TWO BRANDS
    De Klerk, Clasine M.
    Wieten, Els
    van der Steen, Annemieke
    Ramakers, Christian
    Hansen, Bettina
    Kuipers, Ernst J.
    Lansdorp-Vogelaar, Iris
    Bossuyt, Patrick
    Spaander, Manon
    Dekker, Evelien
    GASTROENTEROLOGY, 2018, 154 (06) : S569 - S570
  • [43] A prospective study of faecal immunochemical testing following polypectomy in a colorectal cancer screening population
    Gibson, David J.
    Nolan, Blathnaid
    Rea, Joanna
    Buckley, Maire
    Horgan, Gareth
    Sheahan, Kieran
    Doherty, Glen A.
    O'Donoghue, Diarmuid
    Mulcahy, Hugh E.
    Smith, Alan
    Cullen, Garret
    FRONTLINE GASTROENTEROLOGY, 2018, 9 (04) : 295 - 299
  • [44] Faecal haemoglobin concentrations by gender and age: implications for population-based screening for colorectal cancer
    McDonald, Paula J.
    Strachan, Judith A.
    Digby, Jayne
    Steele, Robert J. C.
    Fraser, Callum G.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (05) : 935 - 940
  • [45] Negative emotions and cancer fatalism are independently associated with uptake of Faecal Immunochemical Test-based colorectal cancer screening: Results from a population-based study
    Clarke, Nicholas
    Kearney, Patricia M.
    Gallagher, Pamela
    McNamara, Deirdre
    O'Morain, Colm A.
    Sharp, Linda
    PREVENTIVE MEDICINE, 2021, 145
  • [46] Impact on colorectal cancer mortality of screening programmes based on the faecal immunochemical test
    Zorzi, Manuel
    Fedeli, Ugo
    Schievano, Elena
    Bovo, Emanuela
    Guzzinati, Stefano
    Baracco, Susanna
    Fedato, Chiara
    Saugo, Mario
    Tos, Angelo Paolo Dei
    GUT, 2015, 64 (05) : 784 - 790
  • [47] Different seasons with decreased performance of immunochemical faecal occult blood tests in colorectal cancer screening
    van Rossum, Leo G. M.
    van Oijen, Martijn G. H.
    GUT, 2011, 60 (09) : 1303 - 1304
  • [48] Diagnostic accuracy of immunochemical versus guaiac faecal occult blood tests for colorectal cancer screening
    Adolfo Parra-Blanco
    Antonio Z. Gimeno-García
    Enrique Quintero
    David Nicolás
    Santiago G. Moreno
    Alejandro Jiménez
    Manuel Hernández-Guerra
    Marta Carrillo-Palau
    Yoshinobu Eishi
    Julio López-Bastida
    Journal of Gastroenterology, 2010, 45 : 703 - 712
  • [49] Prospective cohort study of compliance with faecal immunochemical tests for colorectal cancer screening in Hong Kong
    Wong, Martin C. S.
    Ching, Jessica Y. L.
    Lam, Thomas Y. T.
    Luk, Arthur K. C.
    Hirai, Hoyee W.
    Griffiths, Sian M.
    Chan, Francis K. L.
    Sung, Joseph J. Y.
    PREVENTIVE MEDICINE, 2013, 57 (03) : 227 - 231
  • [50] Making colorectal cancer screening FITTER for purpose with quantitative faecal immunochemical tests for haemoglobin (FIT)
    Fraser, Callum G.
    Halloran, Stephen P.
    Allison, James E.
    Young, Graeme P.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (11) : 2065 - 2067