The evidence for abandoning the amniotic fluid index in favor of the single deepest pocket

被引:39
|
作者
Magann, Everett F.
Chauhan, Suneet P.
Doherty, Dorota A.
Magann, Marcia I.
Morrison, John C.
机构
[1] Aurora Hlth Care, W Allis, WI 53227 USA
[2] Naval Med Ctr Portsmouth, Dept Obstet, Portsmouth, VA USA
[3] Naval Med Ctr Portsmouth, Dept Gynecol, Portsmouth, VA USA
[4] Univ Western Australia, Perth, WA 6009, Australia
[5] Univ Mississippi, Med Ctr, Jackson, MS 39216 USA
关键词
amniotic fluid index (AFI); single deepest pocket (SDP); pregnancy; outcome; oligohydramnios;
D O I
10.1055/s-2007-986689
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
This study assessed whether the amniotic fluid index (AFI) or the single deepest pocket (SDP) is the best technique to estimate amniotic fluid volume. The AFI and SDP were compared to a dye-determined or directly measured amniotic fluid volume. A PUBMED search from 1990 to 2006 was conducted using the search terms "single deepest pocket" or "largest vertical pocket" or "maximum vertical pocket" or "2X1 pocket" AND "amniotic fluid index". One study compared the AM and SDP to a dye-determined amniotic fluid volume. There were 1219 publications that used the search term SDP-LVP-MVP versus 4378 using AFI. Twenty publications contained both the AFI and SDP, but only six compared the AFI and SDP. Both the AFI and the SDP poorly identified abnormal amniotic fluid volumes, and neither technique was superior to the other. The AFI identifies a significantly greater number of women as having oligohydramnios versus the SDP but without any difference in perinatal outcomes. Compared with SDP, AM excessively characterizes a greater number of pregnancies as having oligohydrammos leading to more interventions without improvement in perinatal. outcome. The AFI should be abandoned and the SDP used to estimate amniotic fluid volume.
引用
收藏
页码:549 / 555
页数:7
相关论文
共 50 条
  • [31] Reference values for the single deepest vertical pocket to assess the amniotic fluid volume in the second and third trimesters of pregnancy
    Peixoto, Alberto Borges
    Rodrigues da Cunha Caldas, Taciana Mara
    Giannecchini, Camila Vieira
    Rolo, Liliam Cristine
    Martins, Wellington P.
    Araujo Junior, Edward
    JOURNAL OF PERINATAL MEDICINE, 2016, 44 (06) : 723 - 727
  • [32] ULTRASOUND ASSESSMENT OF AMNIOTIC-FLUID VOLUME - A COMPARISON OF THE SINGLE DEEPEST POOL AND AMNIOTIC-FLUID INDEX TO PREDICT PERINATAL MORBIDITY
    AJAYI, RA
    SOOTHILL, PW
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1991, 1 (06) : 401 - 404
  • [33] On the term "single deepest dial" technique for assessment of amniotic fluid volume
    Tsai, Horng-Jyh
    TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2023, 62 (02):
  • [34] Single Deepest Vertical Pocket or Amniotic Fluid Index as Evaluation Test for Predicting Adverse Pregnancy Outcome (SAFE trial): A Multicenter, Open-Label, Randomized Controlled Trial
    Kehl, Sven
    ZEITSCHRIFT FUR GEBURTSHILFE UND NEONATOLOGIE, 2018, 222 (01): : 28 - 30
  • [35] Single deepest vertical pocket or amniotic fluid index as evaluation test for predicting adverse pregnancy outcome (SAFE trial): a multicenter, open-label, randomized controlled trial
    Kehl, S.
    Schelkle, A.
    Thomas, A.
    Puhl, A.
    Meqdad, K.
    Tuschy, B.
    Berlit, S.
    Weiss, C.
    Bayer, C.
    Heimrich, J.
    Dammer, U.
    Raabe, E.
    Winkler, M.
    Faschingbauer, F.
    Beckmann, M. W.
    Suetterlin, M.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2016, 47 (06) : 674 - +
  • [36] The vaginal fluid index (VFI), a hidden 5th amniotic fluid pocket
    Zipori, Yaniv
    Lauterbach, Roy
    Hajaj, Areen
    Justman, Naphthali
    Ginsberg, Yuval
    Khatib, Nizar
    Weiner, Zeev
    Beloosesky, Ron
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2021, 224 (02) : S288 - S288
  • [37] SUPERIORITY OF THE 4-QUADRANT SUM OVER THE SINGLE-DEEPEST-POCKET TECHNIQUE IN ULTRASONOGRAPHIC IDENTIFICATION OF ABNORMAL AMNIOTIC-FLUID VOLUMES
    MOORE, TR
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1990, 163 (03) : 762 - 767
  • [38] Single Deepest Vertical Pocket or Amniotic Fluid Index as Evaluation Test for Predicting Adverse Pregnancy Outcome (SAFE Trial): A Multicenter, Open-Label, Randomized Controlled Trial EDITORIAL COMMENT
    Kehl, S.
    Schelkle, A.
    Thomas, A.
    Puhl, A.
    Meqdad, K.
    Tuschy, B.
    Berlit, S.
    Weiss, C.
    Bayer, C.
    Heimrich, J.
    Dammer, U.
    Raabe, E.
    Winkler, M.
    Faschingbauer, F.
    Beckmann, M. W.
    Suetterlin, M.
    OBSTETRICAL & GYNECOLOGICAL SURVEY, 2016, 71 (10) : 578 - 580
  • [39] SUPERIORITY OF AMNIOTIC-FLUID INDEX OVER AMNIOTIC-FLUID POCKET MEASUREMENT FOR PREDICTING BAD FETAL-OUTCOME
    YOUSSEF, AA
    ABDULLA, SA
    SAYED, EH
    SALEM, HT
    ABDELALIM, AM
    DEVOE, LD
    SOUTHERN MEDICAL JOURNAL, 1993, 86 (04) : 426 - 429
  • [40] INTRAOBSERVER RELIABILITY OF AMNIOTIC-FLUID VOLUME ESTIMATION BY 2 TECHNIQUES - AMNIOTIC-FLUID INDEX VS MAXIMUM VERTICAL POCKET
    WILLIAMS, K
    WITTMANN, B
    DANSEREAU, J
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1993, 3 (05) : 346 - 349