The development of a matrix metalloproteinase-1 biosensor based on the surface plasmon resonance imaging technique

被引:29
|
作者
Tokarzewicz, Anna [1 ]
Romanowicz, Lech [2 ]
Sveklo, Iosif [3 ]
Gorodkiewicz, Ewa [1 ]
机构
[1] Univ Bialystok, Inst Chem, Dept Electrochem, Bialystok, Poland
[2] Med Univ Bialystok, Dept Med Biochem, Bialystok, Poland
[3] Univ Bialystok, Inst Expt Phys, Dept Phys, Bialystok, Poland
关键词
SENSOR DEVELOPMENT; POTENT INHIBITOR; GOLD SURFACE;
D O I
10.1039/c6ay01856d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The purpose of this study was to create a new, highly selective biosensor, which uses surface plasmon resonance as a detection method for the quantitative determination of the matrix metalloproteinase-1. The main part of the biosensor is an immobilized rabbit anti-human matrix metalloproteinase-1 antibody, which binds the enzyme from the sample. The analytical response signal of the biosensor is in the range of 0.05-20.00 ng ml(-1). The detection limit is 9 pg ml(-1), and the limit of quantification is 18 pg ml(-1). The biosensor was used to measure the matrix metalloproteinase- 1 concentration in the blood plasma of healthy persons and patients with bladder cancer with good results (good tolerance of the potential interferents). To validate the new analytical method, measurements of serum matrix metalloproteinase-1 concentration in the biological samples by Enzyme-Linked Immunosorbent Assay (ELISA) were conducted. Good correlation between these two methods was found. The developed biosensor can be successfully used for the quantitative determination of matrix metalloproteinase-1 in laboratories.
引用
下载
收藏
页码:6428 / 6435
页数:8
相关论文
共 50 条
  • [41] Design and synthesis of sulfur based inhibitors of matrix metalloproteinase-1
    Fujisawa, T
    Odake, S
    Ogawa, Y
    Yasuda, J
    Morita, Y
    Morikawa, T
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2002, 50 (02) : 239 - 252
  • [42] Infrared Surface Plasmon Resonance Biosensor
    Cleary, Justin W.
    Medhi, Gautam
    Peale, Robert E.
    Buchwald, Walter R.
    Edwards, Oliver
    Oladeji, Isaiah
    ADVANCED ENVIRONMENTAL, CHEMICAL, AND BIOLOGICAL SENSING TECHNOLOGIES VII, 2010, 7673
  • [43] Surface plasmon resonance biosensor chips
    Kim, Moonil
    Han, Sang Hee
    Shin, Yong-Beom
    Chung, Bong Hyun
    BIOCHIP JOURNAL, 2007, 1 (02) : 81 - 89
  • [44] Characterization of surface plasmon resonance biosensor
    Xiao, CD
    Sui, SF
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 66 (1-3) : 174 - 177
  • [45] Association of matrix metalloproteinase-1, matrix metalloproteinase-9, tissue inhibitor of matrix metalloproteinase-1, and interleukin-6 with epicardial and myocardial perfusion
    Tanindi, Asli
    Sahinarslan, Asife
    Elbeg, Sehri
    Cemri, Mustafa
    CORONARY ARTERY DISEASE, 2011, 22 (04) : 253 - 258
  • [46] Surface Plasmon Resonance Imaging biosensor for cystatin determination based on the application of bromelain, ficin and chymopapain
    Gorodkiewicz, Ewa
    Breczko, Joanna
    Sankiewicz, Anna
    FOLIA HISTOCHEMICA ET CYTOBIOLOGICA, 2012, 50 (01) : 130 - 136
  • [47] A New Analytical Method for Determination of Cathepsin L Based on the Surface Plasmon Resonance Imaging Biosensor
    Tokarzewicz, Anna
    Romanowicz, Lech
    Sankiewicz, Anna
    Hermanowicz, Adam
    Sobolewski, Krzysztof
    Gorodkiewicz, Ewa
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2019, 20 (09)
  • [48] Plasma matrix metalloproteinase-1 and tissue inhibitor of metalloproteinase-1 as biomarkers of ulcerative colitis activity
    Alicja Wiercinska-Drapalo
    Jerzy Jaroszewicz
    Robert Flisiak
    Danuta Prokopowicz
    World Journal of Gastroenterology, 2003, 9 (12) : 2843 - 2845
  • [49] Assessment of Matrix Metalloproteinase-1 and its Tissue Inhibitor of Metalloproteinase-1 in Pre-eclampsia
    Gupta, Madhur
    Chari, Suresh
    INTERNATIONAL JOURNAL OF SCIENTIFIC STUDY, 2016, 3 (11) : 70 - 73
  • [50] Plasma matrix metalloproteinase-1 and tissue inhibitor of metalloproteinase-1 as biomarkers of ulcerative colitis activity
    Wiercinska-Drapalo, A
    Jaroszewicz, J
    Flisiak, R
    Prokopowicz, D
    WORLD JOURNAL OF GASTROENTEROLOGY, 2003, 9 (12) : 2843 - 2845