The development of a matrix metalloproteinase-1 biosensor based on the surface plasmon resonance imaging technique

被引:29
|
作者
Tokarzewicz, Anna [1 ]
Romanowicz, Lech [2 ]
Sveklo, Iosif [3 ]
Gorodkiewicz, Ewa [1 ]
机构
[1] Univ Bialystok, Inst Chem, Dept Electrochem, Bialystok, Poland
[2] Med Univ Bialystok, Dept Med Biochem, Bialystok, Poland
[3] Univ Bialystok, Inst Expt Phys, Dept Phys, Bialystok, Poland
关键词
SENSOR DEVELOPMENT; POTENT INHIBITOR; GOLD SURFACE;
D O I
10.1039/c6ay01856d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The purpose of this study was to create a new, highly selective biosensor, which uses surface plasmon resonance as a detection method for the quantitative determination of the matrix metalloproteinase-1. The main part of the biosensor is an immobilized rabbit anti-human matrix metalloproteinase-1 antibody, which binds the enzyme from the sample. The analytical response signal of the biosensor is in the range of 0.05-20.00 ng ml(-1). The detection limit is 9 pg ml(-1), and the limit of quantification is 18 pg ml(-1). The biosensor was used to measure the matrix metalloproteinase- 1 concentration in the blood plasma of healthy persons and patients with bladder cancer with good results (good tolerance of the potential interferents). To validate the new analytical method, measurements of serum matrix metalloproteinase-1 concentration in the biological samples by Enzyme-Linked Immunosorbent Assay (ELISA) were conducted. Good correlation between these two methods was found. The developed biosensor can be successfully used for the quantitative determination of matrix metalloproteinase-1 in laboratories.
引用
下载
收藏
页码:6428 / 6435
页数:8
相关论文
共 50 条
  • [1] Surface plasmon resonance based biosensor for discovery of new matrix metalloproteinase-9 inhibitors
    Salehabadi, Hafezeh
    Khajeh, Khosro
    Dabirmanesh, Bahareh
    Biglar, Mahmood
    Mohseni, Sara
    Amanlou, Massoud
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 263 : 143 - 150
  • [2] Surface plasmon resonance based biosensor technique: A review
    Guo, Xiaowei
    JOURNAL OF BIOPHOTONICS, 2012, 5 (07) : 483 - 501
  • [3] A surface plasmon resonance array biosensor based on spectroscopic imaging
    O'Brien, MJ
    Pérez-Luna, VH
    Brueck, SRJ
    López, GP
    BIOSENSORS & BIOELECTRONICS, 2001, 16 (1-2): : 97 - 108
  • [4] SURFACE PLASMON RESONANCE IMAGING BIOSENSOR BASED ON GRAPHENE MULTILAYER
    Maharana, Pradeep Kumar
    Srivastava, Triranjita
    Jha, Rajan
    2012 INTERNATIONAL CONFERENCE ON FIBER OPTICS AND PHOTONICS (PHOTONICS), 2012,
  • [5] Biosensor arrays based on surface plasmon resonance phase imaging
    Wong, C. L.
    Ho, H. P.
    Suen, Y. K.
    Chow, Winnie W. Y.
    Wu, S. Y.
    Li, W. J.
    Kong, S. K.
    Lin, Chinlon
    PROCEEDINGS OF INTERNATIONAL SYMPOSIUM ON BIOPHOTONICS, NANOPHOTONICS AND METAMATERIALS, 2006, : 91 - +
  • [6] Polarimetric surface plasmon resonance imaging biosensor
    Duval, Aurelien
    Laisne, Aude
    Pompon, Denis
    Held, Sylvain
    Bellemain, Alain
    Moreau, Julien
    Canva, Michael
    OPTICS LETTERS, 2009, 34 (23) : 3634 - 3636
  • [7] Polarimetric surface plasmon resonance imaging biosensor
    Duval, A.
    Bardin, F.
    Moreau, J.
    Aide, A.
    Bellemain, A.
    Canva, M.
    NOVEL OPTICAL INSTRUMENTATION FOR BIOMEDICAL APPLICATIONS III, 2007, 6631
  • [8] Development of low-cost biosensor arrays based on phase imaging of surface plasmon resonance
    Ho, HP
    2005 IEEE LEOS Annual Meeting Conference Proceedings (LEOS), 2005, : 165 - 166
  • [9] Surface plasmon resonance imaging biosensor for cathepsin G based on a potent inhibitor: Development and applications
    Gorodkiewicz, Ewa
    Sienczyk, Marcin
    Regulska, Elzbieta
    Grzywa, Renata
    Pietrusewicz, Ewa
    Lesner, Adam
    Lukaszewski, Zenon
    ANALYTICAL BIOCHEMISTRY, 2012, 423 (02) : 218 - 223
  • [10] An Array Detection Biosensor Based on Surface Plasmon Resonance Interferometric Imaging
    Wang, Daqian
    Deng, Yan
    Ding, Xiang
    Ding, Lili
    Zhang, Enyao
    Yu, Xinglong
    SENSOR LETTERS, 2011, 9 (02) : 728 - 731