Cone beam computed tomography and image registration based on target area for stereotactic body radiation therapy of lung cancer

被引:1
|
作者
Gui, Long-Gang [1 ]
Shi, Miao [1 ]
Li, Jun [1 ]
机构
[1] Northern Jiangsu Peoples Hosp, Radiotherapy Ctr, Yangzhou 225001, Jiangsu, Peoples R China
关键词
Lung cancer; SBRT; CBCT; image registration; dosimetric parameter; INTENSITY-MODULATED RADIOTHERAPY; CLINICAL-OUTCOMES; DIAGNOSTIC-VALUE; CT; IRRADIATION;
D O I
10.1080/16878507.2021.1981754
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper aims to compare the dosimetric parameters of the original plan and the simulated plan to explore the clinical value of cone beam CT and planned CT image registration based on the target area. The results showed that Dmax, Dmin, dmean and V60 of PTV in the original plan were (108.3 +/- 1.1)%, (97.2 +/- 0.3)%, (102.6 +/- 0.6)% and (95.2 +/- 0.6)% respectively. The Dmax of spinal cord was (9.6 +/- 1.8) gy, the V20 of lung was (5.2 +/- 1.9)%, and the dmean of lung was (- 3.7 +/- 1.5) gy; however, when the target area was translated in the three directions of the patient's back, right side and foot, the dosimetric parameters of the target area (Dmax, Dmin and V60), dmean and V20 of lung and Dmax of spinal cord showed slight differences, which all met the limit requirements of target area and dangerous organs (OARs) (RTOG) 0915 report. Therefore, target based image registration is feasible. If the registration translation error is less than or equal to 1 cm, there is no need to re move the treatment bed according to the registration error.
引用
收藏
页码:404 / 411
页数:8
相关论文
共 50 条
  • [1] Interobserver Comparison on Patient Positioning Using 4 Different Computed Tomography Datasets for Image Registration With Cone Beam Computed Tomography in Lung Stereotactic Body Radiation Therapy
    Oechsner, M.
    Chizzali, B.
    Devecka, M.
    Wilkens, J.
    Combs, S. E.
    Duma, M. N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E665 - E665
  • [2] Evaluation of 4D Cone Beam Computed Tomography for Target Localization in Stereotactic Body Radiation Therapy for Early Lung Cancer
    Glick, D.
    Karan, T.
    Le, K.
    Allibhai, Z.
    Taremi, M. M.
    Moseley, D. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S143 - S143
  • [3] Phantom Study of Cone Beam Computed Tomography Setup Accuracy in Stereotactic Body Radiation Therapy for Lung Cancer Treatment
    Huang, L.
    Papiez, L.
    Papiez, E.
    Solberg, T.
    Timmerman, R.
    MEDICAL PHYSICS, 2010, 37 (06) : 3092 - +
  • [4] Using previously registered cone beam computerized tomography images to facilitate online computerized tomography to cone beam computerized tomography image registration in lung stereotactic body radiation therapy
    Liang, Jian
    Liu, Qiang
    Grills, Inga
    Guerrero, Thomas
    Stevens, Craig
    Yan, Di
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (04):
  • [5] COST ANALYSIS OF STEREOTACTIC BODY RADIATION THERAPY USING DAILY CONE BEAM COMPUTED TOMOGRAPHY FOR EARLY STAGE LUNG CANCER
    Owen, T.
    Ploquin, N.
    Lau, H.
    Dunscombe, P.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S37 - S37
  • [6] Image guided radiation therapy using cone-beam computed tomography in stereotactic radiosurgery for lung tumor
    Song, S.
    Choi, E.
    Lee, J.
    Kim, W.
    Park, S.
    Shin, S.
    Lee, S.
    Ahn, S.
    Kim, J.
    Park, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S482 - S482
  • [7] Planning Target Volume Margin Suitability in Lung Stereotactic Body Radiation Therapy: A Preliminary Evaluation using Cone-beam Computed Tomography
    Mathew, L.
    Swaminath, A.
    Szabo, J.
    Wierzbicki, M.
    MEDICAL PHYSICS, 2012, 39 (07) : 4620 - 4620
  • [8] "Dose of the day" based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy
    Yuan, Zilong
    Rong, Yi
    Benedict, Stanley H.
    Daly, Megan E.
    Qiu, Jianfeng
    Yamamoto, Tokihiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 88 - 94
  • [9] Evaluation of kV Cone Beam Computed Tomography-Based Setup Errors in Stereotactic Body Radiation Therapy for Liver Cancer
    Li, T.
    Li, F.
    Clump, D. A., II
    Heron, D. E.
    Huq, M. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E662 - E662
  • [10] Registration uncertainties between 3D cone beam computed tomography and different reference CT datasets in lung stereotactic body radiation therapy
    Oechsner, Markus
    Chizzali, Barbara
    Devecka, Michal
    Combs, Stephanie Elisabeth
    Wilkens, Jan Jakob
    Duma, Marciana Nona
    RADIATION ONCOLOGY, 2016, 11