Tissue Doppler imaging of mitral annular motion is an effective surrogate of left ventricular dyssynchrony and predicts response to cardiac resynchronization therapy

被引:1
|
作者
Yuan, Xia Ping
White, James A.
Yee, Raymond
Drangova, Maria
机构
[1] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] London Hlth Sci Ctr, Div Cardiol, London, ON, Canada
[3] Univ Western Ontario, Dept Med Biophys, London, ON N6A 3K7, Canada
基金
加拿大健康研究院;
关键词
D O I
10.1016/j.echo.2007.02.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Tissue Doppler imaging of basal myocardial segments has been used to predict response to cardiac resynchronization therapy (CRT). However, in patients with poor imaging windows mechanical dyssynchrony may be difficult to assess because of poor tissue characterization. We tested the hypothesis that tissue Doppler evaluation of the mitral annulus can accurately identify the presence of left ventricular dyssynchrony and predict the response to CRT. Methods: Tissue Doppler imaging of 6 mitral annular sites and 6 basal myocardial segments was performed in 21 patients with heart failure, before and at 3 months after CRT device implantation. Time to peak systolic velocity (T-s) was determined for each site and intraventricular dyssynchrony was defined as the maximal difference in T-s between measurement sites. Results: Excellent correlation was observed between mitral annular and basal segment measurements of T-s (r = 0.90, P < .001 at baseline and r = 0.93, P < .001 at follow-up) and maximal difference in T-s between measurement sites (r = 0.90, P < .001 at baseline and r = 0.90, P = .003 at follow-up). Receiver operator characteristic analysis for the mitral annulus measurements demonstrated that an optimal cut-off value of T-s = 179 milliseconds differentiated responders from nonresponders with a sensitivity of 86% and specificity of 82%; similarly, a cut-off value of maximal difference in T-s between measurement sites = 105 milliseconds for intraventricular dyssynchrony differentiated responders from nonresponders with a sensitivity of 86% and specificity of 73%. Conclusion: Tissue Doppler assessment of mitral annular motion can accurately identify left ventricular dyssynchrony and predict positive response to CRT.
引用
收藏
页码:1186 / 1193
页数:8
相关论文
共 50 条
  • [41] Utility of echocardiographic radial strain imaging to quantify left ventricular dyssynchrony and predict acute response to cardiac resynchronization therapy
    Dohi, K
    Suffoletto, MS
    Schwartzman, D
    Ganz, L
    Pinsky, MR
    Gorcsan, J
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (01): : 112 - 116
  • [42] Measures of left ventricular dyssynchrony and the correlation to clinical and echocardiographic response after cardiac resynchronization therapy
    Abdelhadi, Raed
    Adelstein, Evan
    Voigt, Andrew
    Gorcsan, John
    Saba, Samir
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (05): : 598 - 601
  • [43] Tissue Doppler imaging predicts improved systolic performance and reversed left ventricular remodeling during long-term cardiac resynchronization therapy
    Sogaard, P
    Egeblad, H
    Kim, WY
    Jensen, HK
    Pedersen, AK
    Kristensen, BO
    Mortensen, PT
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (04) : 723 - 730
  • [44] Left Ventricular Dyssynchrony Can Lead to Reverse Ventricular Rotation as a Novel Predictor of Response to Cardiac Resynchronization Therapy
    Oe, Yoko
    Nishigami, Kazuhiro
    Koyama, Junjiro
    Honda, Toshihiro
    Nakao, Koichi
    CIRCULATION, 2009, 120 (18) : S770 - S770
  • [45] Acute left ventricular dyssynchrony improvement predicts long-term benefit from cardiac resynchronization therapy
    Capasso, Fabio
    Giunta, Anna
    De Simone, Antonio
    Turco, Pietro
    La Rocca, Vincenzo
    Grimaldi, M. Gabriella
    Iuliano, Assunta
    Stabile, Giuseppe
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 : S62 - S65
  • [46] Tissue synchronisation imaging accurately measures left ventricular dyssynchrony and predicts response to cardiac resynchronisation therapy (vol 93, pg 1034, 2007)
    Van de Veire, N. R.
    Bleeker, G. B.
    De Sutter, J.
    HEART, 2008, 94 (12) : 1655 - 1655
  • [47] A Novel Method to Predict Response to Cardiac Resynchronization Therapy by Tissue Mitral Annular Displacement (TMAD)
    Iwakura, Katsuomi
    Okamura, Atsunori
    Koyama, Yasushi
    Date, Motoo
    Inoue, Koichi
    Toyoshima, Yuko
    Ozawa, Makito
    Masuda, Masaharu
    Nakatani, Shimpei
    Sotomi, Yohei
    Sumiyoshi, Akinori
    Nozato, Yoichi
    Fujii, Kenshi
    CIRCULATION, 2012, 126 (21)
  • [48] Tissue Doppler Imaging Dyssynchrony Parameter Derived From the Myocardial Active Wall Motion Improves Prediction of Responders for Cardiac Resynchronization Therapy
    Sakamaki, Fumiko
    Seo, Yoshihiro
    Ishizu, Tomoko
    Yanaka, Satomi
    Atsumi, Akiko
    Yamamoto, Masayoshi
    Machino-Ohtsuka, Tomoko
    Kawamura, Ryo
    Yamasaki, Hiro
    Igarashi, Miyako
    Yoshida, Kentaro
    Sekiguchi, Yukio
    Tada, Hiroshi
    Aonuma, Kazutaka
    CIRCULATION JOURNAL, 2012, 76 (03) : 689 - 697
  • [49] Tissue Doppler Imaging Dyssynchrony Parameter Based on the First Active Wall Motion Improve Ability in Predicting Responders of Cardiac Resynchronization Therapy
    Sakamaki, Fumiko
    Seo, Yoshihiro
    Atsumi, Akiko
    Yamamoto, Masayoshi
    Harimura, Yoshie
    Machino, Tomoko
    Kawamura, Ryo
    Ishizu, Tomoko
    Aonuma, Kazutaka
    CIRCULATION, 2010, 122 (21)
  • [50] Comparison of left ventricular discoordination and dyssynchrony assessment by radial strain imaging in candidates for cardiac resynchronization therapy
    Chan, Y. H.
    Wu, L. S.
    Yeh, Y. H.
    Wang, C. L.
    Ho, Y. J.
    Hsu, L. A.
    Kuo, C. T.
    EUROPEAN HEART JOURNAL, 2012, 33 : 677 - 677