Spectral propagation-based x-ray phase-contrast computed tomography

被引:1
|
作者
Schaff, Florian [1 ]
Pollock, James A. [1 ]
Morgan, Kaye S. [1 ]
Kitchen, Marcus J. [1 ,2 ]
机构
[1] Monash Univ, Sch Phys & Astron, Clayton, Vic, Australia
[2] Monash Univ, Ritchie Ctr, Clayton, Vic, Australia
基金
澳大利亚研究理事会;
关键词
x-ray phase contrast; computed tomography; spectral imaging; phase retrieval; electron density; effective atomic number; RETRIEVAL;
D O I
10.1117/1.JMI.9.3.031506
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Propagation-based x-ray imaging (PBI) is a phase-contrast technique that is employed in high-resolution imaging by introducing some distance between sample and detector. PBI causes characteristic intensity fringes that have to be processed with appropriate phase-retrieval algorithms, which has historically been a difficult task for objects composed of several different materials. Spectral x-ray imaging has been introduced to PBI to overcome this issue and to potentially utilize the spectral nature of the data for material-specific imaging. We aim to explore the potential of spectral PBI in three-dimensional computed tomography (CT) imaging in this work. Approach: We demonstrate phase-retrieval for experimental high-resolution spectral propagation-based CT data of a simple two-component sample, as well as a multimaterial capacitor test sample. Phase-retrieval was performed using an algorithm based on the Alvarez-Macovski model. Virtual monochromatic (VMI) and effective atomic number images were calculated after phase-retrieval. Results: Phase-retrieval results from the spectral data set show a distinct gray-level for each material with no residual phase-contrast fringes. Several representations of the phase-retrieved data are provided. The VMI is used to display an attenuation-equivalent image at a chosen display energy of 80 keV, to provide good separation of materials with minimal noise. The effective atomic number image shows the material composition of the sample. Conclusions: Spectral photon-counting detector technology has already been shown to be compatible with spectral PBI, and there is a foreseeable need for robust phase-retrieval in high-resolution, spectral x-ray CT in the future. Our results demonstrate the feasibility of phase-retrieval for spectral PBI CT. (C) 2022 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Analytical evaluation of the signal and noise propagation in x-ray differential phase-contrast computed tomography
    Raupach, Rainer
    Flohr, Thomas G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (07): : 2219 - 2244
  • [32] Observation of human tissues with phase-contrast X-ray computed tomography
    Momose, A
    Takeda, T
    Itai, Y
    Tu, JH
    Hirano, K
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 365 - 374
  • [33] Hard X-ray phase-contrast tomography of non-homogeneous specimens: grating interferometry versus propagation-based imaging
    Ruiz-Yaniz, Maite
    Zanette, Irene
    Sarapata, Adrian
    Birnbacher, Lorenz
    Marschner, Mathias
    Chabior, Michael
    Olbinado, Margie
    Pfeiffer, Franz
    Rack, Alexander
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 1202 - 1209
  • [34] Quantitative X-ray phase-contrast computed tomography at 82 keV
    Willner, Marian
    Bech, Martin
    Herzen, Julia
    Zanette, Irene
    Hahn, Dieter
    Kenntner, Johannes
    Mohr, Juergen
    Rack, Alexander
    Weitkamp, Timm
    Pfeiffer, Franz
    OPTICS EXPRESS, 2013, 21 (04): : 4155 - 4166
  • [35] Energy Optimisation of Propagation-Based Phase-Contrast Computed Tomography: A Quantitative Image Quality Assessment
    Lim, Belinda
    Lewis, Sarah
    Arhatari, Benedicta D.
    Nesterets, Yakov
    Mayo, Sheridan
    Thomposon, Darren
    Fox, Jane
    Kumar, Beena
    Hausermann, Daniel
    Maksimenko, Anton
    Hall, Christopher
    Dimmock, Matthew
    Lockie, Darren
    Rickard, Mary
    Giannotti, Nicola
    Peele, Andrew
    Quiney, Harry
    Gureyev, Timur E.
    Brennan, Patrick
    Taba, Seyedamir T.
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [36] X-ray Phase-Contrast Computed Tomography of Human Coronary Arteries
    Hetterich, Holger
    Willner, Marian
    Habbel, Christopher
    Herzen, Julia
    Hoffmann, Verena S.
    Fill, Sandra
    Hipp, Alexander
    Marschner, Mathias
    Schueller, Ulrich
    Auweter, Sigrid
    Massberg, Steffen
    Reiser, Maximilian F.
    Pfeiffer, Franz
    Saam, Tobias
    Bamberg, Fabian
    INVESTIGATIVE RADIOLOGY, 2015, 50 (10) : 686 - 694
  • [37] Helical X-ray phase-contrast computed tomography without phase stepping
    M. Marschner
    M. Willner
    G. Potdevin
    A. Fehringer
    P. B. Noël
    F. Pfeiffer
    J. Herzen
    Scientific Reports, 6
  • [38] Helical X-ray phase-contrast computed tomography without phase stepping
    Marschner, M.
    Willner, M.
    Potdevin, G.
    Fehringer, A.
    Noel, P. B.
    Pfeiffer, F.
    Herzen, J.
    SCIENTIFIC REPORTS, 2016, 6
  • [39] Improvement of spatial resolution in phase-contrast X-ray computed tomography
    Momose, A
    Koyama, I
    Hirano, K
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 71 - 81
  • [40] DEMONSTRATION OF PHASE-CONTRAST X-RAY COMPUTED-TOMOGRAPHY USING AN X-RAY INTERFEROMETER
    MOMOSE, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 352 (03): : 622 - 628