AgNWs-PANI nanocomposite based electrochemical sensor for detection of 4-nitrophenol
被引:132
|
作者:
Zhang, Chao
论文数: 0引用数: 0
h-index: 0
机构:
Gachon Univ, Dept Bionanotechnol, Gyeonggi Do, South KoreaGachon Univ, Dept Bionanotechnol, Gyeonggi Do, South Korea
Zhang, Chao
[1
]
Govindaraju, Saravanan
论文数: 0引用数: 0
h-index: 0
机构:
Gachon Univ, Dept Bionanotechnol, Gyeonggi Do, South KoreaGachon Univ, Dept Bionanotechnol, Gyeonggi Do, South Korea
Govindaraju, Saravanan
[1
]
Giribabu, Krishnan
论文数: 0引用数: 0
h-index: 0
机构:
CSIR, Cent Electrochem Res Inst, Electrod & ElectrocatalysisDiv, Karaikkudi, Tamil Nadu, IndiaGachon Univ, Dept Bionanotechnol, Gyeonggi Do, South Korea
Giribabu, Krishnan
[2
]
Huh, Yun Suk
论文数: 0引用数: 0
h-index: 0
机构:
Inha Univ, BSRC, Dept Biol Engn, Incheon, South KoreaGachon Univ, Dept Bionanotechnol, Gyeonggi Do, South Korea
Huh, Yun Suk
[3
]
论文数: 引用数:
h-index:
机构:
Yun, Kyusik
[1
]
机构:
[1] Gachon Univ, Dept Bionanotechnol, Gyeonggi Do, South Korea
[2] CSIR, Cent Electrochem Res Inst, Electrod & ElectrocatalysisDiv, Karaikkudi, Tamil Nadu, India
[3] Inha Univ, BSRC, Dept Biol Engn, Incheon, South Korea
Silver Nanowire-Polyaniline (AgNWs-PANI) composite modified glassy carbon electrode (GCE) was fabricated for the sensitive electrochemical determination of 4-nitrophenol (4-NP). AgNWs-PANI composite was synthesized in two steps process. The synthesized AgNWs-PANI was characterized by UV-vis, FTIR, SEM and TEM analysis. The electrochemical reduction determination of 4-NP under optimized conditions exhibited a reduction peak at -0.77V with higher current response compared with bare GCE and AgNWs modified glassy carbon electrode (AgNWs/GCE). Effect of pH and scan rate was investigated to examine the proton transfer number, electron transfer number, electron transfer coefficient and standard rate constant of electrode. Under optimized condition, the reduction peak current and the concentration of 4-NP exhibits the linear relation with the concentration range from 0.6-32 mu M, and the limit of detection was determined to be 52 nM (S/N = 3). Although, AgNWs-PANI/GCE were applied to detect the determination the 4-NP in real water samples at the recover ranging from 97.0-101.5%. (C) 2017 Elsevier B.V. All rights reserved.
机构:
Yeungnam Univ, Sch Chem Engn, Gyongsan Si 38541, South KoreaYeungnam Univ, Sch Chem Engn, Gyongsan Si 38541, South Korea
Ramkumar, Ramya
Veerakumar, Pitchaimani
论文数: 0引用数: 0
h-index: 0
机构:
Saveetha Univ, Saveetha Dent Coll & Hosp, Ctr Mol Med & Diagnost COMManD, Dept Biochem,Saveetha Inst Med & Tech Sci SIMATS, Chennai 600077, IndiaYeungnam Univ, Sch Chem Engn, Gyongsan Si 38541, South Korea
Veerakumar, Pitchaimani
Rajendrachari, Shashanka
论文数: 0引用数: 0
h-index: 0
机构:
SR Univ, Sch Sci & Humanities, Dept Chem, Warangal 506371, Telangana, IndiaYeungnam Univ, Sch Chem Engn, Gyongsan Si 38541, South Korea
Rajendrachari, Shashanka
Dhakal, Ganesh
论文数: 0引用数: 0
h-index: 0
机构:
Southern Univ & A&M Coll, Dept Phys, Baton Rouge, LA 70813 USA
Southern Univ & A&M Coll, Nano Mat Lab, Baton Rouge, LA 70813 USAYeungnam Univ, Sch Chem Engn, Gyongsan Si 38541, South Korea
Dhakal, Ganesh
Yun, Jungwon
论文数: 0引用数: 0
h-index: 0
机构:
Yeungnam Univ, Sch Chem Engn, Gyongsan Si 38541, South KoreaYeungnam Univ, Sch Chem Engn, Gyongsan Si 38541, South Korea
Yun, Jungwon
Shim, Jae-Jin
论文数: 0引用数: 0
h-index: 0
机构:
Yeungnam Univ, Sch Chem Engn, Gyongsan Si 38541, South KoreaYeungnam Univ, Sch Chem Engn, Gyongsan Si 38541, South Korea
机构:
Laboratório de Sensores Químicos Portáteis, Instituto de Química, Universidade Estadual de Campinas – UNICAMP, SP, CampinasLaboratório de Sensores Químicos Portáteis, Instituto de Química, Universidade Estadual de Campinas – UNICAMP, SP, Campinas
Corsato P.C.R.
de Lima L.F.
论文数: 0引用数: 0
h-index: 0
机构:
Laboratório de Sensores Químicos Portáteis, Instituto de Química, Universidade Estadual de Campinas – UNICAMP, SP, CampinasLaboratório de Sensores Químicos Portáteis, Instituto de Química, Universidade Estadual de Campinas – UNICAMP, SP, Campinas
de Lima L.F.
Paschoarelli M.V.
论文数: 0引用数: 0
h-index: 0
机构:
Laboratório de Sensores Químicos Portáteis, Instituto de Química, Universidade Estadual de Campinas – UNICAMP, SP, CampinasLaboratório de Sensores Químicos Portáteis, Instituto de Química, Universidade Estadual de Campinas – UNICAMP, SP, Campinas
Paschoarelli M.V.
de Araujo W.R.
论文数: 0引用数: 0
h-index: 0
机构:
Laboratório de Sensores Químicos Portáteis, Instituto de Química, Universidade Estadual de Campinas – UNICAMP, SP, CampinasLaboratório de Sensores Químicos Portáteis, Instituto de Química, Universidade Estadual de Campinas – UNICAMP, SP, Campinas
机构:
Indian Inst Technol, Ctr Res Nanotechnol & Sci, Mumbai 400076, IndiaIndian Inst Technol, Ctr Res Nanotechnol & Sci, Mumbai 400076, India
Wanjari, Vikram P.
Duttagupta, Siddhartha P.
论文数: 0引用数: 0
h-index: 0
机构:
Indian Inst Technol, Ctr Res Nanotechnol & Sci, Mumbai 400076, India
Indian Inst Technol, Dept Elect Engn, Mumbai 400076, IndiaIndian Inst Technol, Ctr Res Nanotechnol & Sci, Mumbai 400076, India
Duttagupta, Siddhartha P.
Singh, Swatantra P.
论文数: 0引用数: 0
h-index: 0
机构:
Indian Inst Technol, Ctr Res Nanotechnol & Sci, Mumbai 400076, India
Indian Inst Technol, Environm Sci & Engn Dept, Mumbai 400076, India
Indian Inst Technol, Interdisciplinary Program Climate Studies, Mumbai 400076, IndiaIndian Inst Technol, Ctr Res Nanotechnol & Sci, Mumbai 400076, India