COMPUTER MODELING OF OPERATION OF THE CONDUCTIVE MHD CENTRIFUGAL PUMP

被引:0
|
作者
Katsnelson, Savelii S. [1 ]
Pozdnyakov, Georgiy A. [1 ]
机构
[1] RAS, Khristianovich Inst Theoret & Appl Mech ITAM SB, Inst Skaya St 4-1, Novosibirsk 630090, Russia
关键词
MHD centrifugal pump; Metal melt; Flow rate; Turbulent flow; Friction coefficient; Mathematic modelling;
D O I
暂无
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
The mathematical model of an MHD centrifugal conductive pump (CCP) is developed, which allows the flow of molten metal in the MHD channel and the output pressure to be calculated as a function of the basic determining major parameters: flow rate, current strength, and magnetic induction. The development and testing of the mathematical model were based on the experimental results obtained for the CCP working model. Determination of friction forces effect in scope of initial system of the MGD-equations is carried out on the basis of the known square-law of the drag for turbulent flow in a pipe, generalized on a case of two-dimensional flows in the channel. On base of the matching of computational and experimental values of pressure at exit of conductive centrifugal pump for different operating modes, dependences of coefficient of drag depending on the determining major parameters were got. The calculations showed that the dependences obtained have universal enough character. The implementation of this model in a computer code can be used to design pumps of this type and to control their operation in the metallurgical process technology.
引用
收藏
页码:7325 / 7332
页数:8
相关论文
共 50 条
  • [21] Experiment of a centrifugal pump during changing speed operation
    Yuan, H. J.
    Shao, J.
    Wu, Y. L.
    Liu, S. H.
    26TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS, PTS 1-7, 2013, 15
  • [23] Monitored centrifugal pump operation: Experience, problems, and prospects
    Yu. I. Ishkov
    Chemical and Petroleum Engineering, 2000, 36 : 164 - 166
  • [24] MATHEMATICAL MODELING OF STATIONARY AND TRANSIENT REGIMES IN THE OPERATION OF A MHD GENERATOR USING AN ANALOG COMPUTER.
    Baranov, A.P.
    Kuznetsov, S.E.
    Popov, Yu.V.
    Magnetohydrodynamics New York, N.Y., 1981, 17 (03): : 289 - 293
  • [25] Modeling and H∞ Control of Centrifugal Pump with Pipeline
    Brezina, T.
    Kovar, J.
    Hejc, T.
    Andrs, A.
    MECHATRONICS: RECENT TECHNOLOGICAL AND SCIENTIFIC ADVANCES, 2011, : 523 - 530
  • [26] Operation effectiveness of wells by enhancing the electric-centrifugal pump
    Zyatikov, P. N.
    Kozyrev, I. N.
    Deeva, V. S.
    XX INTERNATIONAL SCIENTIFIC SYMPOSIUM OF STUDENTS, POSTGRADUATES AND YOUNG SCIENTISTS ON PROBLEMS OF GEOLOGY AND SUBSURFACE DEVELOPMENT, 2016, 43
  • [27] Centrifugal pump operation monitoring with motor phase current measurement
    Ahonen, Tero
    Kortelainen, Juha T.
    Tamminen, Jussi K.
    Ahola, Jero
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 42 (01) : 188 - 195
  • [28] Operation of a centrifugal pump and a liquid ejector with an isobaric mixing chamber
    V. Yu. Aleksandrov
    K. K. Klimovskii
    Russian Engineering Research, 2012, 32 (5-6) : 426 - 429
  • [29] Behaviour of a centrifugal pump during operation in the cavitation-zone
    不详
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1937, 81 : 972 - 973
  • [30] NPSHA CAN MEAN SUCCESS OR FAILURE FOR CENTRIFUGAL PUMP OPERATION
    HODEL, AE