A large area position-sensitive ionization chamber for heavy-ion-induced reaction studies

被引:5
|
作者
Pant, LM [1 ]
Biswas, DC
Dinesh, BV
Thomas, RG
Saxena, A
Sawant, YS
Choudhury, RK
机构
[1] Bhabha Atom Res Ctr, Div Nucl Phys, Bombay 400085, Maharashtra, India
[2] Siesm Array Stn, Bangalore, Karnataka, India
[3] Inst Phys, Bhubaneswar 751007, Orissa, India
关键词
ionization chamber; heavy-ion reactions; mass-energy correlations;
D O I
10.1016/S0168-9002(02)01579-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A large area position-sensitive ionization chamber with a wide dynamic range has been developed to measure the mass, charge and energy of the heavy ions and the fission fragments produced in heavy-ion-induced reactions. The split anode geometry of the detector makes it suitable for both particle identification and energy measurements for heavy ions and fission fragments. The detector has been tested with alpha particles from Am-241-Pu-239 source, fission fragments from Cf-252 and the heavy-ion beams from the 14UD Mumbai Pelletron accelerator facility. Using this detector, measurements on mass and total kinetic energy distributions in heavy-ion-induced fusion-fission reactions have been carried out for a wide range of excitation energies. Results on deep inelastic collisions and mass-energy correlations on different systems using this detector setup are discussed. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:121 / 131
页数:11
相关论文
共 50 条
  • [21] COMBINED IONIZATION-CHAMBER AND POSITION-SENSITIVE PROPORTIONAL COUNTER FOR DETECTION OF HEAVY-IONS IN A MAGNETIC SPECTROGRAPH
    ERSKINE, JR
    STOLTZFUS, JC
    BRAID, TH
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (04): : 602 - 602
  • [22] Development of 1-D position-sensitive ionization chamber used in SSRF
    Zhu, Jing
    Wang, Qi-Sheng
    Huang, Sheng
    Tao, Shi-Xing
    Chen, Ming-Zhi
    Tang, Lin
    He, Jian-Hua
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2010, 18 (03): : 544 - 551
  • [23] DEVELOPMENT OF LARGE-AREA, POSITION-SENSITIVE NEUTRON DETECTORS
    ALBERI, JL
    BROOKHAVEN SYMPOSIA IN BIOLOGY, 1976, (27) : R24 - R42
  • [24] Characteristics of large-area position-sensitive scintillation detectors
    Vasil'chenko, YV
    Gulida, AN
    Dudkin, GN
    Padalko, VN
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1998, 41 (02) : 176 - 182
  • [25] UNIVERSITY OF MISSOURI LARGE AREA POSITION-SENSITIVE NEUTRON DETECTOR
    BERLINER, R
    MILDNER, DFR
    PRINGLE, OA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (03): : 367 - 367
  • [26] New materials for large-area position-sensitive detectors
    Fortunato, E
    Martins, R
    SENSORS AND ACTUATORS A-PHYSICAL, 1998, 68 (1-3) : 244 - 248
  • [27] Characteristics of large-area position-sensitive scintillation detectors
    Vasil'chenko, Yu.V.
    Gulida, A.N.
    Dubkin, G.N.
    Padalko, V.N.
    Pribory i Tekhnika Eksperimenta, 1998, 41 (02): : 36 - 42
  • [28] New materials for large-area position-sensitive detectors
    Fortunato, Elvira
    Martins, Rodrigo
    Sensors and Actuators, A: Physical, 1998, 68 (1 -3 pt 2): : 244 - 248
  • [29] CHANNELING EFFECT IN THE DEAD LAYER OF ION-IMPLANTED, POSITION-SENSITIVE DETECTORS IN HEAVY-ION STUDIES
    MINGAY, DW
    ROSNER, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1984, 1 (01): : 60 - 65
  • [30] A position-sensitive twin ionization chamber for fission fragment and prompt neutron correlation experiments
    Gook, A.
    Geerts, W.
    Hambsch, F. -J.
    Oberstedt, S.
    Vidali, M.
    Zeynalov, Sh.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 830 : 366 - 374