Patient specific IMRT QC tolerance criteria and the detection of systematic errors in MLC leaf position

被引:0
|
作者
Rangel, A. [1 ]
Palte, G.
Dunscombe, P. [1 ,2 ]
机构
[1] Univ Calgary, Dept Phys & Astron, Calgary, AB T2N 1N4, Canada
[2] Univ Calgary, Dept Oncol, Calgary, AB T2N 1N4, Canada
关键词
D O I
10.1118/1.3244153
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:4313 / 4313
页数:1
相关论文
共 50 条
  • [21] Dosimetric impact of systematic MLC positional errors on step and shoot IMRT for prostate cancer: a planning study
    Ung, N. M.
    Harper, C. S.
    Wee, L.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2011, 34 (02) : 291 - 298
  • [22] A systematic analysis of patient specific IMRT QA data
    Su, Z.
    Jin, H.
    Fox, C.
    Li, H.
    Lynch, B.
    Yang, C.
    Li, J.
    Liu, C.
    Palta, J.
    Kim, S.
    MEDICAL PHYSICS, 2006, 33 (06) : 2291 - 2291
  • [23] Evaluation of MLC Leaf Position Accuracy for Static and Dynamic IMRT Treatments Using DAVID In Vivo Dosimetric System
    Karagoz, G.
    Zorlu, F.
    Yeginer, M.
    Yildiz, D.
    Gurkaynak, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S875 - S875
  • [24] Improvement of deep learning prediction model in patient-specific QA for VMAT with MLC leaf position map and patient's dose distribution
    Tozuka, Ryota
    Kadoya, Noriyuki
    Tomori, Seiji
    Kimura, Yuto
    Kajikawa, Tomohiro
    Sugai, Yuto
    Xiao, Yushan
    Jingu, Keiichi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (10):
  • [25] Eliminating Errors in Setup and Positioning for Patient-Specific IMRT QA
    Kamath, S.
    Palta, J.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [26] Sensitivity of MatriXX 2D Array in Detection of MLC Leaf Positioning Errors
    Shang, Q.
    Huang, L.
    Qi, P.
    Xia, P.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [27] Automatic detection of MLC position errors using an EPID based picket fence test
    Christophides, D.
    Davies, A.
    Fleckney, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S703 - S704
  • [28] A quantitative method to the analysis of MLC leaf position and speed based on EPID and EBT3 film for dynamic IMRT treatment with different types of MLC
    Li, Yinghui
    Chen, Lixin
    Zhu, Jinhan
    Wang, Bin
    Liu, Xiaowei
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (04): : 106 - 115
  • [29] Has IMRT Changed the Impact of MLC Leaf Width? A Systematic Review and Meta-Analysis of TPS Studies
    Luzzara, M.
    Santoro, L.
    Brown, K.
    MEDICAL PHYSICS, 2016, 43 (06) : 3540 - 3540
  • [30] Analysis of MLC Errors On Gamma Pass Rates for Patient-Specific and Conventional Phantoms
    Sterling, D.
    Ehler, E.
    MEDICAL PHYSICS, 2015, 42 (06) : 3357 - 3357