For chemical burns a considerable lack of methods exists for defining penetration kinetics and effects of decontamination within biological structures. We demonstrate that time-resolved high-resolution optical coherence tomography can close this gap by monitoring changes in scattering properties and thicknesses of rabbit cornea ex vivo after topical application of different corrosives. Modifications in the corneal microstructure due to direct chemical interaction or changes in the hydration state as a result of osmotic imbalance compromise the corneal transparency. The associated increase in light scattering intensity within the cornea is observed with high spatial and temporal resolution. Parameters affecting the severity of pathophysiological damage like diffusion velocity, depth of penetration, resistance of barriers, and effectiveness of emergency treatment procedures are obtained. This study demonstrates the potential of high-resolution OCT for the visualization and direct non-invasive measurement of specific interaction of chemicals with the eye, exemplified on hydrofluoric acid burn.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] In Vivo Imaging of Retinal and Choroidal Vasculature in the Rodent Eye using Optical Coherence Tomography
    Augustin, Marco
    Fialova, Stanislava
    Plasenzotti, Roberto
    Pircher, Michael
    Hitzenberger, Christoph K.
    Baumann, Bernhard
    OPTICAL COHERENCE IMAGING TECHNIQUES AND IMAGING IN SCATTERING MEDIA, 2015, 9541
  • [22] OPTICAL BIOPSY AND IMAGING USING OPTICAL COHERENCE TOMOGRAPHY
    FUJIMOTO, JG
    BREZINSKI, ME
    TEARNEY, GJ
    BOPPART, SA
    BOUMA, B
    HEE, MR
    SOUTHERN, JF
    SWANSON, EA
    NATURE MEDICINE, 1995, 1 (09) : 970 - 972
  • [23] Static and dynamic imaging of alveoli using optical coherence tomography needle probes
    McLaughlin, Robert A.
    Yang, Xiaojie
    Quirk, Bryden C.
    Lorenser, Dirk
    Kirk, Rodney W.
    Noble, Peter B.
    Sampson, David D.
    JOURNAL OF APPLIED PHYSIOLOGY, 2012, 113 (06) : 967 - 974
  • [24] Confocal Microscopy and Anterior Segment Optical Coherence Tomography Findings After Chemical Alkali Corneal Burn
    Tsoulnaras, Konstantinos I.
    Liakopoulos, Dimitrios A.
    Grentzelos, Michael A.
    Pallikaris, Aristophanis I.
    Mikropoulos, Dimitrios G.
    Kymionis, George D.
    CORNEA, 2016, 35 (10) : e32 - e35
  • [25] Biomedical imaging using optical coherence tomography
    Fujimoto, JG
    18TH CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: OPTICS FOR THE NEXT MILLENNIUM, TECHNICAL DIGEST, 1999, 3749 : 402 - 403
  • [26] Optical coherence elastography: Strain imaging in tissue using optical coherence tomography
    Kennedy, Brendan F.
    Kennedy, Kelsey M.
    Ford, Chris
    McLaughlin, Robert A.
    Bush, Mark B.
    Sampson, David D.
    22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3, 2012, 8421
  • [27] Non-invasive ophthalmic imaging of adult zebrafish eye using optical coherence tomography
    Biomedical Applications Section, Raja Ramanna Centre for Advanced Technology, Indore 452 013, India
    Curr. Sci., 2006, 11 (1506-1510):
  • [28] Non-invasive ophthalmic imaging of adult zebrafish eye using optical coherence tomography
    Rao, K. Divakar
    Verma, Y.
    Patel, H. S.
    Gupta, P. K.
    CURRENT SCIENCE, 2006, 90 (11): : 1506 - 1510
  • [29] Correlative infrared optical coherence tomography and hyperspectral chemical imaging
    Zorin, Ivan
    Su, Rong
    Heise, Bettina
    Lendl, Bernhard
    Brandstetter, Markus
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2020, 37 (09) : B19 - B26
  • [30] Choroidal imaging in gas-filled eye using swept source optical coherence tomography
    Maruko, Ichiro
    Sugano, Yukinori
    Oyamada, Hiroshi
    Sekiryu, Tetsuju
    Iida, Tomohiro
    Akiba, Masahiro
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)