Microfluidic paper-based analytical device by using Pt nanoparticles as highly active peroxidase mimic for simultaneous detection of glucose and uric acid with use of a smartphone

被引:46
|
作者
Zheng, Jie [1 ]
Zhu, Min [2 ]
Kong, Jiao [1 ]
Li, Zimu [1 ]
Jiang, Jianming [1 ]
Xi, Yachao [1 ]
Li, Fang [1 ]
机构
[1] Hefei Univ Technol, Sch Chem & Chem Engn, Anhui Prov Key Lab Adv Catalyt Mat & React Engn, Hefei 230009, Anhui, Peoples R China
[2] PLA Army Acad Artillery & Air Def, Hefei 230031, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
mu PAD; Pt NPs; Glucose; Uric acid; Smartphone; COLORIMETRIC ASSAY;
D O I
10.1016/j.talanta.2021.122954
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein, a simple microfluidic paper-based analytical device (mu PAD) by using platinum nanoparticles (Pt NPs) as highly active peroxidase mimic for simultaneous determination of glucose and uric acid was fabricated. The mu PAD consisted of one sample transportation layer, four paper-based detection chips, and two layers of hydrophobic polyethylene terephthalate (PET) films. The four detection chips were immobilized with various chromogenic reagents, Pt NPs, and specific oxidase (glucose oxidase or uricase). H2O2 generated by specific enzymatic reactions could oxidize co-immobilized chromogenic reagents to produce colored products by using Pt NPs as efficient catalyst. The multi-layered structure of mu PAD could effectively improve the color uniformity and color intensity. Total color intensity from each two detection chips modified with distinct chromogenic reagents were used for quantitative analysis of glucose and uric acid, respectively, resulting in significantly improved sensitivity. The linear range for glucose and uric acid detection was 0.01-5.0 mM and 0.01-2.5 mM, respectively. Satisfied results were obtained for glucose and uric acid detection in real serum samples. An easy-to-use smartphone APP was developed for convenient and intelligent detection. The developed mu PAD integrated with smartphone as detector holds great applicability for simple and portable on-site analysis.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Development of a paper-based analytical device for colorimetric detection of uric acid using gold nanoparticles-graphene oxide (AuNPs-GO) conjugates
    Kumar, Sanjay
    Bhushan, Pulak
    Bhattacharya, Shantanu
    ANALYTICAL METHODS, 2016, 8 (38) : 6965 - 6973
  • [32] A novel screen-printed microfluidic paper-based electrochemical device for detection of glucose and uric acid in urine (vol 18, 92, 2016)
    Yao, Yong
    Zhang, Chunsun
    BIOMEDICAL MICRODEVICES, 2022, 24 (03)
  • [33] Development of an origami microfluidic paper-based analytical device for highly sensitive detection of dual biomarkers in artificial saliva
    Chen, Chaozhan
    Ran, Bin
    Liu, Bo
    Xiao, Yunmian
    Tang, Gongbin
    Shen, Teng
    Liang, Jialin
    Liang, Zhongwei
    MICROCHEMICAL JOURNAL, 2025, 210
  • [34] A portable smartphone detection of ctDNA using MnB2 nanozyme and paper-based analytical device
    Yang, Siyi
    Zhao, Liangyi
    Yang, Xiao
    Yang, Liyu
    Fa, Huanbao
    Wang, Yongzhong
    Huo, Danqun
    Hou, Changjun
    Zhong, Daidi
    Yang, Mei
    TALANTA, 2024, 278
  • [35] Simultaneous colorimetric detection of improvised explosive compounds using microfluidic paper-based analytical devices (μPADs)
    Peters, Kelley L.
    Corbin, Inge
    Kaufman, Lindsay M.
    Zreibe, Kyle
    Blanes, Lucas
    McCord, Bruce R.
    ANALYTICAL METHODS, 2015, 7 (01) : 63 - 70
  • [36] Simple Microfluidic Paper-Based Analytical Device (p-PAD) Coupled with Smartphone for Mn(II) Detection Using Tannin as a Green Reagent
    Nitti, Fidelis
    Ati, Wendelina Archangela
    de Rozari, Philiphi
    Ola, Pius Dore
    Tambaru, David
    Kadang, Luther
    INDONESIAN JOURNAL OF CHEMISTRY, 2023, 23 (04) : 1095 - 1107
  • [37] Visual quantification of Hg on a microfluidic paper-based analytical device using distance-based detection technique
    Cai, Longfei
    Fang, Yanling
    Mo, Yuanhui
    Huang, Yongshi
    Xu, Chunxiu
    Zhang, Zhen
    Wang, Maoxian
    AIP ADVANCES, 2017, 7 (08)
  • [38] Paper-Based Microfluidic Analytical Device Patterned by Label Printer for Point-of-Care Blood Glucose and Hematocrit Detection Using 3D-Printed Smartphone Cassette
    Cai, Zong-Xiao
    Jiang, Ming-Zhang
    Chuang, Ya-Ju
    Kuo, Ju-Nan
    SENSORS, 2024, 24 (15)
  • [39] Antimony-doped tin oxide nanoparticles as peroxidase mimics for paper-based colorimetric detection of glucose using smartphone read-out
    Li, Yana
    Sun, Jun
    Mao, Wei
    Tang, Sheng
    Liu, Kai
    Qi, Tong
    Deng, Huimin
    Shen, Wei
    Chen, Lizhuang
    Peng, Luming
    MICROCHIMICA ACTA, 2019, 186 (07)
  • [40] Antimony-doped tin oxide nanoparticles as peroxidase mimics for paper-based colorimetric detection of glucose using smartphone read-out
    Yana Li
    Jun Sun
    Wei Mao
    Sheng Tang
    Kai Liu
    Tong Qi
    Huimin Deng
    Wei Shen
    Lizhuang Chen
    Luming Peng
    Microchimica Acta, 2019, 186