Computer-Aided Detection of Pulmonary Nodules based on SVM in Thoracic CT Images

被引:0
|
作者
Eskandarian, Parinaz [1 ]
Bagherzadeh, Jamshid [2 ]
机构
[1] Islamic Azad Univ, Urmia Branch, Dept Comp Engn, Orumiyeh, Iran
[2] Urmia Univ, Fac Comp Engn, Orumiyeh, Iran
关键词
Computer-aided detection; CT imaging; Solitary Pulmonary Nodules; support vector machine; LUNG NODULES; AUTOMATED DETECTION; TOMOGRAPHY SCANS; CHEST CT; SEGMENTATION; CLASSIFICATION; TRANSFORM;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Computer-Aided diagnosis of Solitary Pulmonary Nodules using the method of X-ray CT images is the early detection of lung cancer. In this study, a computer-aided system for detection of pulmonary nodules on CT scan based support vector machine classifier is provided for the diagnosis of solitary pulmonary nodules. So at the first step, by data mining techniques, volume of data are reduced. Then divided by the area of the chest, the suspicious nodules are identified and eventually nodules are detected. In comparison with the threshold-based methods, support vector machine classifier to classify more accurately describes areas of the lungs. In this study, the false positive rate is reduced by combination of threshold with support vector machine classifier. Experimental results based on data from 147 patients with lung LIDC image database show that the proposed system is able toobtained sensitivity of 89.9% and false positive of 3.9 per scan. In comparison to previous systems, the proposed system demonstrates good performance.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Computer-aided diagnosis in thoracic CT
    Li, Q
    Li, F
    Suzuki, K
    Shiraishi, J
    Abe, H
    Engelmann, R
    Nie, YK
    MacMahon, H
    Doi, K
    SEMINARS IN ULTRASOUND CT AND MRI, 2005, 26 (05) : 357 - 363
  • [42] Automatic detection of pulmonary nodules at spiral CT: clinical application of a computer-aided diagnosis system
    Dag Wormanns
    Martin Fiebich
    Mustafa Saidi
    Stefan Diederich
    Walter Heindel
    European Radiology, 2002, 12 : 1052 - 1057
  • [43] Automatic detection of pulmonary nodules at spiral CT: clinical application of a computer-aided diagnosis system
    Wormanns, D
    Fiebich, M
    Saidi, M
    Diederich, S
    Heindel, W
    EUROPEAN RADIOLOGY, 2002, 12 (05) : 1052 - 1057
  • [44] Influence of spectral detector CT based monoenergetic images on the computer-aided detection of pulmonary artery embolism
    Kroeger, Jan Robert
    Hickethier, Tilman
    Pahn, Gregor
    Gerhardt, Felix
    Maintz, David
    Bunck, Alexander C.
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 95 : 242 - 248
  • [45] Value of a Computer-aided Detection System Based on Chest Tomosynthesis Imaging for the Detection of Pulmonary Nodules
    Yamada, Yoshitake
    Shiomi, Eisuke
    Hashimoto, Masahiro
    Abe, Takayuki
    Matsusako, Masaki
    Saida, Yukihisa
    Ogawa, Kenji
    RADIOLOGY, 2018, 287 (01) : 333 - 339
  • [46] Computer aided detection of pulmonary nodules on multislice CT data
    Rogalla, P
    Wiemker, R
    Hein, E
    Blaffert, T
    RADIOLOGY, 2002, 225 : 477 - 478
  • [47] A new method for computer aided detection of pulmonary nodules in X-ray CT images
    Homma, Noriyasu
    Takei, Kazunori
    Ishibashi, Tadashi
    ADVANCES ON ARTIFICIAL INTELLIGENCE, KNOWLEDGE ENGINEERING AND DATA BASES, PROCEEDINGS, 2008, : 379 - +
  • [48] Standard moments based vessel bifurcation filter for computer-aided detection of pulmonary nodules
    Fotin, Sergei V.
    Reeves, Anthony P.
    Biancardi, Alberto M.
    Yankelevitz, David F.
    Henschke, Claudia I.
    MEDICAL IMAGING 2010: COMPUTER - AIDED DIAGNOSIS, 2010, 7624
  • [49] Computer-aided detection of pulmonary nodules:: influence of nodule characteristics on detection performance
    Marten, K
    Engelke, C
    Seyfarth, T
    Grillhösl, A
    Obenauer, S
    Rummeny, EJ
    CLINICAL RADIOLOGY, 2005, 60 (02) : 196 - 206
  • [50] Automatic segmentation of pulmonary parenchyma in thoracic CT and computer-aided diagnosis
    Department of Biomedical Engineering, South China University of Technology, Guangzhou 510640, China
    不详
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2008, 36 (01): : 72 - 75