Preconcentration of heavy metal ions on magnetic multi-walled carbon nanotubes using magnetic solid-phase extraction and determination in vegetable samples by electrothermal atomic absorption spectrometry: Box-Behnken design

被引:15
|
作者
Khodadadi, Sara [1 ]
Konoz, Elahe [1 ]
Niazi, Ali [1 ]
Ezabadi, Ali [1 ]
机构
[1] Islamic Azad Univ, Dept Chem, Cent Tehran Branch, Tehran, Iran
关键词
Magnetic solid-phase extraction; Multi-walled carbon nanotubes; Electrothermal atomic absorption spectrometry; Heavy metals; Vegetable samples; Box-Behnken design; WATER SAMPLES; CADMIUM; COPPER; COMPOSITES; CHROMIUM; REMOVAL; CD(II); PB(II); NICKEL; PB;
D O I
10.1007/s11696-022-02330-w
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, a simple, rapid, and efficient analytical method was proposed for the preconcentration and determination of trace amounts of cadmium and chromium in vegetable samples using magnetic solid-phase extraction (MSPE) coupled with electrothermal atomic absorption spectrometry (ETAAS) detection. Magnetic multi-walled carbon nanotubes (MWCNTs) as an effective adsorbent were synthesized and characterization was performed using scanning electron microscope, transmission electron microscopy, Fourier-transform infrared spectroscopy, X-ray diffraction, and vibrating-sample magnetometer. The experimental parameters were optimized using Box-Behnken design and maximum absorbance of Cd (II) and Cr (VI) was obtained at pH = 5, adsorbent dosage of 0.02 and 0.12 g, ligand concentration of 4 mu g L-1, and extraction time of 22.5 min. The accuracy was assessed through proper recoveries in the range of 58.63-99.03% and 62.86-89.69% for Cd (II) and Cr (VI), respectively. In addition, precision was evaluated with a relative standard deviation (RSD) below 2.8% for both analytes. Linearity was in the range of 5-100 mu g L-1 for both metal ions. The limit of detection and limit of quantification values were found below 0.3 mu g L-1 and 0.3 mu g L-1 using the ETAAS technique, respectively. The magnetic MWCNTs as a promising and low-cost adsorbent can be used in MSPE along with AAS approaches for the extraction and determination of heavy metal ions in several vegetable samples.
引用
收藏
页码:6735 / 6751
页数:17
相关论文
共 50 条
  • [31] Magnetic multi-walled carbon nanotubes assisted solid phase extraction and detection of neonicotinoid pesticides in honey and tea samples
    Ding, Zixuan
    Zhang, Kouhua
    Yang, Wenjuan
    Fu, Qiang
    Jia, Li
    MICROCHEMICAL JOURNAL, 2023, 195
  • [32] Solid phase extraction on multiwalled carbon nanotubes and flame atomic absorption spectrometry combination for determination of some metal ions in environmental and food samples
    Soylak, M.
    Yilmaz, E.
    Ghaedi, M.
    Montazerozohori, M.
    TOXICOLOGICAL AND ENVIRONMENTAL CHEMISTRY, 2011, 93 (05): : 873 - 885
  • [33] Simultaneous Preconcentration and Determination of Ni and Pb in Water Samples by Solid-Phase Extraction and Flame Atomic Absorption Spectrometry
    Ciftci, Harun
    Temuz, Mehmet Mursit
    Ciftci, Esen
    JOURNAL OF AOAC INTERNATIONAL, 2013, 96 (04) : 875 - 879
  • [34] PEGylation of magnetic multi-walled carbon nanotubes for enhanced selectivity of dispersive solid phase extraction
    Zeng, Qiong
    Liu, Yi-Ming
    Jia, Yan-Wei
    Wan, Li-Hong
    Liao, Xun
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 71 : 186 - 194
  • [35] Magnetic multi-walled carbon nanotubes as a solid phase extraction adsorbent for the determination of 13 phthalate acid esters in water samples by gas chromatography-mass spectrometry
    Fu Shanliang
    Ding Li
    Zhu Shaohua
    Jiao Yanna
    Gong Qiang
    Chen Jitao
    Wu Xinhua
    Wang Libing
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (08) : 737 - 742
  • [36] Preconcentration and determination of boron in milk, infant formula, and honey samples by solid phase extraction-electrothermal atomic absorption spectrometry
    Lopez-Garcia, I.
    Vinas, P.
    Romero-Romero, R.
    Hernandez-Cordoba, M.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (02) : 179 - 183
  • [37] Flame atomic absorption spectrometric determination of copper, lead, and cadmium in Gastrodiae rhizoma samples after preconcentration using magnetic solid-phase extraction
    Tu, Yujiao
    Ju, Shuangqiao
    Wang, Pingyan
    SPECTROSCOPY LETTERS, 2016, 49 (04) : 249 - 256
  • [38] Multi-residue determination of pesticides in water using multi-walled carbon nanotubes solid-phase extraction and gas chromatography-mass spectrometry
    Wang, Shuo
    Zhao, Peng
    Min, Guang
    Fang, Guozhen
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1165 (1-2) : 166 - 171
  • [39] Determination of six sulfonylurea herbicides in environmental water samples by magnetic solid-phase extraction using multi-walled carbon nanotubes as adsorbents coupled with high-performance liquid chromatography
    Ma, Jiping
    Jiang, Lianhua
    Wu, Gege
    Xia, Yan
    Lu, Wenhui
    Li, Jinhua
    Chen, Lingxin
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1466 : 12 - 20
  • [40] Ultrasound-assisted magnetic solid phase extraction of lead and thallium in complex environmental samples using magnetic multi-walled carbon nanotubes/zeolite nanocomposite
    Gugushe, Aphiwe Siyasanga
    Mpupa, Anele
    Nomngongo, Philiswa N.
    MICROCHEMICAL JOURNAL, 2019, 149