Diagnostic utility of additional conventional techniques after endobronchial ultrasonography guidance during transbronchial biopsy

被引:41
|
作者
Kunimasa, Kei [1 ]
Tachihara, Motoko [1 ]
Tamura, Daisuke [1 ]
Tokunaga, Shuntaro [1 ]
Nakata, Kyosuke [1 ]
Hazeki, Nobuko [1 ]
Kamiryo, Hiroshi [1 ]
Kobayashi, Kazuyuki [1 ]
Sakai, Yasuhiro [2 ]
Nishimura, Yoshihiro [1 ]
机构
[1] Kobe Univ, Div Resp Med, Dept Internal Med, Grad Sch Med, Kobe, Hyogo, Japan
[2] Kobe Univ, Div Diagnost Pathol, Grad Sch Med, Kobe, Hyogo, Japan
关键词
bronchoscopy; endosonography; image-guided biopsy; lung cancer; pulmonary nodules; GUIDE SHEATH; IMAGES; YIELD;
D O I
10.1111/resp.12813
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background and objectiveEndobronchial ultrasonography with a guide sheath transbronchial biopsy (EBUS-GS TBB) has been used to diagnose peripheral pulmonary lesions (PPLs). In this study, we evaluated the diagnostic utility of conventional TBB after EBUS-GS TBB. MethodsA retrospective analysis of patients who underwent conventional TBB after EBUS-GS TBB for PPL between August 1, 2012 and December 31, 2014. We performed multivariate analysis to examine the association of various clinical factors, including EBUS probe distance and sample size area, with diagnostic yield. ResultsOf 88 eligible patients, 57 (65%) were successfully diagnosed by EBUS-GS TBB. In 31 patients not diagnosed by EBUS-GS TBB, 15 (48%) were successfully diagnosed by additional conventional TBB. Ground glass opacity (GGO) was a significant factor associated with the diagnostic yield of additional conventional TBB following EBUS-GS TBB. Multivariate analysis and receiver operator curves revealed that distance between the PPL and the EBUS probe of less than 2.55mm favored the utility of conventional TBB. ConclusionAdditional conventional TBB after EBUS-GS TBB could be a useful procedure for the diagnosis of ground glass opacity PPLs and in cases of a distance of less than 2.55mm between the EBUS probe and the lesion. Our study shows that additional conventional transbronchial biopsy after endobronchial ultrasonography with a guide sheath could be useful for the diagnosis of ground glass opacity--peripheral pulmonary lesions and in cases were the distance of the endobronchial ultrasonography probe to the lesion is shorter than 2.55mm.
引用
收藏
页码:1100 / 1105
页数:6
相关论文
共 50 条
  • [21] Endobronchial ultrasonography guidance for transbronchial needle aspiration using a double-channel bronchoscope
    Kanoh, K
    Miyazawa, T
    Kurimoto, I
    Iwamoto, Y
    Miyazu, Y
    Kohno, N
    CHEST, 2005, 128 (01) : 388 - 393
  • [22] Factors related to the diagnosis of lung cancer by transbronchial biopsy with endobronchial ultrasonography and a guide sheath
    Kurihara, Yuki
    Tashiro, Hiroki
    Takahashi, Koichiro
    Tajiri, Ryo
    Kuwahara, Yuki
    Kajiwara, Kokoro
    Komiya, Natsuko
    Ogusu, Shinsuke
    Nakashima, Chiho
    Nakamura, Tomomi
    Kimura, Shinya
    Sueoka-Aragane, Naoko
    THORACIC CANCER, 2022, 13 (24) : 3459 - 3466
  • [24] DIAGNOSTIC METHODS AND UTILITY OF TRANSBRONCHIAL LUNG BIOPSY IN THE DIAGNOSISOF LYMPHANGIOLEIOMYOMATOSIS
    Muraki, Keiko
    Hayashi, Takuo
    Ando, Katsutoshi
    Hoshika, Yoshito
    Sato, Teruhiko
    Mitani, Keiko
    Nagaoka, Tetsutaro
    Uekusa, Toshimasa
    Seyama, Kuniaki
    Takahashi, Kazuhisa
    RESPIROLOGY, 2013, 18 : 138 - 138
  • [25] Diagnostic utility of conventional transbronchial needle aspiration in older patients
    Ulasli, Sevinc Sarinc
    Koksal, Deniz
    Karcioglu, Oguz
    Babaoglu, Elif
    Onder, Sevgen
    Emri, Salih
    EUROPEAN GERIATRIC MEDICINE, 2018, 9 (02) : 263 - 267
  • [26] Diagnostic utility of conventional transbronchial needle aspiration in older patients
    Sevinc Sarinc Ulasli
    Deniz Koksal
    Oguz Karcioglu
    Elif Babaoglu
    Sevgen Onder
    Salih Emri
    European Geriatric Medicine, 2018, 9 : 263 - 267
  • [28] Diagnostic value and safety of endobronchial ultrasonography with a guide sheath transbronchial biopsy for diagnosing peripheral pulmonary lesions in patients with interstitial lung disease
    Ito, Takayasu
    Okachi, Shotaro
    Iwano, Shingo
    Kinoshita, Fumie
    Wakahara, Keiko
    Hashimoto, Naozumi
    Chen-Yoshikawa, Toyofumi Fengshi
    JOURNAL OF THORACIC DISEASE, 2022, 14 (11) : 4361 - 4371
  • [29] FACTORS INFLUENCING DIAGNOSTIC YIELD OF TRANSBRONCHIAL BIOPSY USING ENDOBRONCHIAL ULTRASONOGRAPHY WITH A GUIDE SHEATH (EBUS-GS) IN PERIPHERAL PULMONARY LESIONS
    Imaizumi, Kazuyoshi
    Minesawa, Tomoyuki
    Isogai, Sumito
    Okamura, Takuya
    Morikawa, Sayako
    Niwa, Yoshikazu
    Takeyama, Tomoko
    Mieno, Yuki
    Morishita, Mariko
    Uozu, Sakurako
    Hoshino, Tami
    Hayashi, Masamichi
    Nakanishi, Toru
    Okazawa, Mitsushi
    RESPIROLOGY, 2013, 18 : 56 - 56
  • [30] The Value of Additional Conventional Transbronchial Biopsy in the Negative Results of Rapid On-site Evaluation During Endobronchial Ultrasound With Guide Sheath to Diagnose Small Peripheral Lung Cancer
    Ito, Takayasu
    Okachi, Shotaro
    Ikenouchi, Tadasuke
    Ushijima, Futoshi
    Ohashi, Takamasa
    Ogawa, Masahiro
    Nagahama, Masato
    Hashimoto, Naozumi
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2021, 20