Application of semi-active tuned mass dampers to base-excited systems

被引:39
|
作者
Setareh, M [1 ]
机构
[1] Virginia Tech, Coll Architecture & Urban Studies, Blacksburg, VA 24061 USA
来源
关键词
semi-active TMD; base excitation; ground-hook TMD (GHTMD); optimum parameters;
D O I
10.1002/eqe.19
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A continuously variable semi-active damper is used in a tuned mass damper (TMD) to reduce the level of vibration of a single-degree-of-freedom system subjected to harmonic base excitations. The ground-hook dampers as have been used in the auto-industry are being studied here. Using these dampers a new class of tuned mass dampers, named as ground hook tuned mass dampers (GHTMD) is being introduced. In order to generalize the design properties of the GHTMDs, they are defined in terms of non-dimensional parameters. The optimum design parameters of GHTMDs for lightly damped systems are obtained based on the minimization of the steady-state displacement response of the main mass. These parameters are computed for different mass ratios and main system damping ratios. Frequency responses of the resulting systems are compared to that of equivalent TMDs using passive dampers. In addition, other characteristics of this system as compared to the passive TMDs are discussed. A design guide to obtain the optimum parameters of GHTMD using the developed diagrams in this paper based on non-dimensional values is presented. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:449 / 462
页数:14
相关论文
共 50 条
  • [21] Semi-active tuned mass damper building systems: Design
    Chey, Min-Ho
    Chase, J. Geoffrey
    Mander, John B.
    Carr, Athol J.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2010, 39 (02): : 119 - 139
  • [22] Passive, semi-active, and active tuned-liquid-column dampers
    Chen, Yung-Hsiang
    Ding, Ying-Jan
    STRUCTURAL ENGINEERING AND MECHANICS, 2008, 30 (01) : 1 - 20
  • [23] Mitigation of wind response of a tall building using semi-active tuned mass dampers
    Kang, Joowon
    Kim, Hyun-Su
    Lee, Dong-Guen
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2011, 20 (05): : 552 - 565
  • [24] Optimum inelastic tuned mass dampers without using viscous elements for minimizing steady-state vibration of base-excited systems
    Bagheri, Saman
    Rahmani-Dabbagh, Vahid
    JOURNAL OF VIBRATION AND CONTROL, 2021, 27 (17-18) : 1968 - 1978
  • [25] Mechanism and application of semi-active MR dampers
    Sui, Li-Li
    Ou, Jin-Ping
    2002, China Educational Publication Import and Export Corporation (35): : 9 - 13
  • [26] Vibration control of seismic structures using semi-active friction multiple tuned mass dampers
    Lin, Chi-Chang
    Lu, Lyan-Ywan
    Lin, Ging-Long
    Yang, Ting-Wei
    ENGINEERING STRUCTURES, 2010, 32 (10) : 3404 - 3417
  • [27] Vibration control of steel frames with setback irregularities equipped with semi-active tuned mass dampers
    Hosseini, Seyed Amin
    Jahangiri, Vahid
    Massumi, Ali
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 211
  • [28] Use of semi-active tuned mass dampers to control footbridges subjected to synchronous lateral excitation
    Ferreira, Fernando
    Moutinho, Carlos
    Cunha, Alvaro
    Caetano, Elsa
    JOURNAL OF SOUND AND VIBRATION, 2019, 446 : 176 - 194
  • [29] Control of flapwise vibrations in wind turbine blades using semi-active tuned mass dampers
    Arrigan, John
    Pakrashi, Vikram
    Basu, Biswajit
    Nagarajaiah, Satish
    STRUCTURAL CONTROL & HEALTH MONITORING, 2011, 18 (08): : 840 - 851
  • [30] Semi-active phase control of tuned mass dampers for translational and torsional vibration mitigation of structures
    Lai, Yong-An
    Chung, Lap-Loi
    Yang, Chuang-Sheng Walter
    Wu, Lai-Yun
    STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (09):