Anaesthesia and automatic implantable cardioverter-defibrillator.

被引:0
|
作者
Stojeba, N
Steib, A
Fournier, S
Loewenthal, A
Chauvin, M
机构
来源
关键词
anaesthesia; automatic implantable cardioverter-defibrillator; equipment;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Since the introduction of first generation automatic implantable cardioverter defibrillators (AICD) in 1980, an increasing number of such devices have been inserted in patients at high risk for sudden death by Ventricular tachycardia or fibrillation (VT/VF). With the improvement of technology and implanting techniques, devices may be inserted at present subcutaneously into the abdominal or the thoracic wall, rather than by thoracotomy. The anaesthesist is involved in the primary implantation of the AICD and the secondary testing of efficiency. Implantation generally requires general anaesthesia and the extension of monitoring is guided by the patient's underlying disease(s). The efficiency of the implanted system is tested one to two months later in inducing VT/VF under general anaesthesia and in determining the defibrillation threshold. The anaesthetist may also have to take care of patients with a AICD. For such cases the following recommendations can be made: a) gloves shoud be worn by doctors and nurses coming into contact with these patients, in order to limit the risk of electrification; b) a ring magnet must be available to inactivate the unit; c) in case of external defibrillation, the external paddles should be oriented perpendicularly to the line joining the two implanted electrodes; d) AICD should be disabled during electrocautery and prior to electroconvulsive therapy; e) the assistance of a electrophysiologist may be helpful for the management of these patients.
引用
收藏
页码:295 / 303
页数:9
相关论文
共 50 条
  • [31] STEREO SPEAKER SILENCES AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    KARSON, TH
    GRACE, K
    DENES, P
    NEW ENGLAND JOURNAL OF MEDICINE, 1989, 320 (24): : 1628 - 1629
  • [32] THE CASE FOR EXPLANTATION OF THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    KOWEY, PR
    FRIEHLING, TD
    MARINCHAK, RA
    KLINE, RA
    STOHLER, JL
    YEAGER, LA
    AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (12): : 1210 - 1211
  • [33] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - APPEARANCE AND COMPLICATIONS
    LURIE, AL
    UDOFF, EJ
    REID, PJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 145 (04) : 723 - 725
  • [34] CLINICAL-PERFORMANCE OF THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    BRODMAN, R
    FISHER, JD
    GABRY, MD
    FURMAN, S
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03): : 651 - 651
  • [35] COMPLICATION OF AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IMPLANTATION
    SEINFELD, FI
    RAY, SC
    ANNALS OF THORACIC SURGERY, 1993, 55 (06): : 1600 - 1600
  • [36] PREDICTORS OF AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (AICD) DISCHARGE
    KELLY, PA
    CANNOM, DS
    FINKELSTEIN, D
    GARAN, H
    MCCOMB, JM
    ILVENTO, JP
    RUSKIN, JN
    CIRCULATION, 1987, 76 (04) : 310 - 310
  • [37] AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR - SURGICAL APPROACHES FOR IMPLANTATION
    SHEPARD, RB
    GOLDIN, MD
    LAWRIE, GM
    WATKINS, L
    WINKLE, RA
    MOWER, MM
    THOMAS, AC
    NISAM, S
    JOURNAL OF CARDIAC SURGERY, 1992, 7 (03) : 208 - 224
  • [38] USE OF THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - REPLY
    PLATIA, EV
    GRIFFITH, LSC
    WATKINS, L
    MOWER, MM
    GUARNIERI, T
    REID, PR
    NEW ENGLAND JOURNAL OF MEDICINE, 1986, 315 (01): : 64 - 64
  • [39] AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR - COST-EFFECTIVENESS
    HAUER, RNW
    WEVER, EFD
    CRIJNS, HJGM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (03): : 559 - 563
  • [40] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - IMPLICATIONS FOR ANESTHETISTS
    CARR, CME
    WHITELEY, SM
    ANAESTHESIA, 1991, 46 (09) : 737 - 740