A comparison of the laryngeal tube-S™ and Proseal™ laryngeal mask during outpatient surgical procedures

被引:5
|
作者
Zand, F. [1 ]
Amini, A. [1 ]
Sadeghi, S. E. [1 ]
Gureishi, M. [1 ]
Chohedri, A. [1 ]
机构
[1] Shiraz Univ Med Sci, Namazi Hosp, Dept Anaesthesiol, Shiraz 7193711351, Iran
关键词
anaesthetic equipment; laryngeal masks; intubation intratracheal;
D O I
10.1017/S0265021507000804
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The Laryngeal Tube Sonda (R) (ITS) and the ProSeal (R) Laryngeal Mask Airway (PLMA) are two new devices introduced for maintaining the airway during controlled ventilation under general anaesthesia. The present investigation compared their performance in a randomized controlled study. Methods: One hundred ASA 1-11 patients, aged 18-60 yr undergoing elective minor surgery, were randomized to receive either an ITS (n = 50) or PLMA (n = 50) for airway management. After induction of general anaesthesia, the devices were inserted, its correct placement was verified and airway leak pressure was measured. Ease of insertion, quality of airway seal, fibre-optic view and postoperative pharyngeal morbidity were examined. Results: There were no differences in patient characteristics for both groups. First-time and second-time success rates were comparable for both groups (86 vs. 88%, and 96 vs. 9896 in ITS and PLMA groups, respectively). The airway of one patient in each group could not be managed with these devices after three attempts. Time until delivery of first tidal volume for ITS and PLMA was 24.5 +/- 6.9 and 28.8 +/- 10.3 s. Fixation and manipulation time was 54.9 +/- 15.2 and 73.2 +/- 25 s, respectively (P < 0.05). Airway seal pressure (cm H(2)O) for ITS and PLMA was 20 +/- 8.6 and 24.1 +/- 10.8, respectively (P = 0.04). Patients were questioned on a variety of postoperative pharyngeal morbidities. Only hoarseness was more frequent in the ITS group. Conclusions: Both devices provide a secure airway, are similar in clinical utility and are easy to insert. Better airway seal was detected in the PLMA group.
引用
收藏
页码:847 / 851
页数:5
相关论文
共 50 条
  • [41] The ProSeal Laryngeal Mask Airway and the Laryngeal Tube Sonda: a randomised cross-over study
    Cook, TM
    Cranshaw, JH
    ANAESTHESIA, 2005, 60 (08) : 831 - 832
  • [42] Proseal Laryngeal mask airway or Classic Laryngeal mask airway in spontaneous ventilation?
    Galarioti, V.
    Michaloliakou, Ch.
    Kalanzi, N.
    Pagoulatou, A.
    Andrianopoulou, A.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 68 - 68
  • [43] Comparisons of clinical performance of guardian laryngeal mask with laryngeal mask airway ProSeal
    Ajay Kumar Pajiyar
    Zhiting Wen
    Haiyun Wang
    Lin Ma
    Lumin Miao
    Guolin Wang
    BMC Anesthesiology, 15
  • [44] The ProSeal laryngeal mask in myasthenia gravis
    Gardner, SV
    Evans, NR
    ANAESTHESIA AND INTENSIVE CARE, 2002, 30 (05) : 671 - 674
  • [45] Gastric insufflation with the ProSeal laryngeal mask
    Brimacombe, J
    Keller, C
    Berry, A
    ANESTHESIA AND ANALGESIA, 2001, 92 (06): : 1614 - 1615
  • [46] The ProSeal™ laryngeal mask airway in children
    Lopez-Gil, M
    Brimacombe, J
    PEDIATRIC ANESTHESIA, 2005, 15 (03) : 229 - 234
  • [47] Comparisons of clinical performance of guardian laryngeal mask with laryngeal mask airway ProSeal
    Pajiyar, Ajay Kumar
    Wen, Zhiting
    Wang, Haiyun
    Ma, Lin
    Miao, Lumin
    Wang, Guolin
    BMC ANESTHESIOLOGY, 2015, 15
  • [48] Failed gastric tube insertion with the ProSeal™ laryngeal mask airway (PLMA)
    Keller, C
    Brimacombe, J
    ANAESTHESIA, 2003, 58 (07) : 713 - 714
  • [49] A novel use for the ProSeal laryngeal mask
    Green, S
    Soskin, M
    ANAESTHESIA, 2003, 58 (11) : 1143 - 1143
  • [50] Malposition of the ProSeal laryngeal mask - Response
    Brimacombe, J
    Kennaugh, S
    Berry, A
    Keller, C
    ANESTHESIA AND ANALGESIA, 2002, 94 (05): : 1367 - 1367