Validity of Measurement for Trailing Limb Angle and Propulsion Force during Gait Using a Magnetic Inertial Measurement Unit

被引:16
|
作者
Miyazaki, Takasuke [1 ,2 ]
Kawada, Masayuki [3 ]
Nakai, Yuki [1 ]
Kiyama, Ryoji [3 ]
Yone, Kazunori [3 ]
机构
[1] Kagoshima Univ, Grad Sch Hlth Sci, 8-35-1 Sakuragaoka, Kagoshima, Kagoshima 8908544, Japan
[2] Tarumizu Cent Hosp, Tarumizu Municipal Med Ctr, Dept Rehabil, 1-140 Kinkocho, Tarumizu, Kagoshima 8912124, Japan
[3] Kagoshima Univ, Fac Med, Sch Hlth Sci, Course Phys Therapy, 8-35-1 Sakuragaoka, Kagoshima, Kagoshima 8908544, Japan
关键词
GROUND REACTION FORCES; PARETIC PROPULSION; WALKING; SPEED; ANKLE; INDIVIDUALS; ADAPTATION; KINEMATICS; MOBILITY; BALANCE;
D O I
10.1155/2019/8123467
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Propulsion force and trailing limb angle (TLA) are meaningful indicators for evaluating quality of gait. This study examined the validity of measurement for TLA and propulsion force during various gait conditions using magnetic inertial measurement units (IMU), based on measurements using a three-dimensional motion analysis system and a force platform. Eighteen healthy males (mean age 25.2 +/- 3.2 years, body height 1.70 +/- 0.06 m) walked with and without trunk fluctuation at preferred, slow, and fast velocities. IMU were fixed on the thorax, lumbar spine, and right thigh and shank. IMU calculated the acceleration and tilt angles in a global coordinate system. TLA, consisting of a line connecting the hip joint with the ankle joint, and the laboratory's vertical axis at late stance in the sagittal plane, was calculated from thigh and shank segment angles obtained by IMU, and coordinate data from the motion analysis system. Propulsion force was estimated by the increment of velocity calculated from anterior acceleration measured by IMU fixed on the thorax and lumbar spine, and normalized impulse of the anterior component of ground reaction force (AGRF) during late stance. Similarity of TLA measured by IMU and the motion analysis system was tested by the coefficient of multiple correlation (CMC), intraclass correlation coefficient (ICC), and root mean square (RMS) of measurement error. Relationships between normalized impulse of AGRF and increments of velocity, as measured by IMU, were tested using correlation analysis. CMC of TLA was 0.956-0.959. ICC between peak TLAs was 0.831-0.876 (p<0.001), and RMS of error was 1.42 degrees-1.92 degrees. Velocity increment calculated from acceleration on the lumbar region showed strong correlations with normalized impulse of AGRF (r=0.755-0.892, p<0.001). These results indicated a high validity of estimation of TLA and propulsion force by IMU during various gait conditions; these methods would be useful for best clinical practice.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Comparative Study on Classifying Gait With a Single Trunk-Mounted Inertial-Magnetic Measurement Unit
    Full, Katharina
    Leutheuser, Heike
    Schlessman, Jason
    Armitage, Roger
    Eskofier, Bjoern M.
    2015 IEEE 12TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2015,
  • [42] Validity and Test-Retest Reliability of Spatiotemporal Running Parameter Measurement Using Embedded Inertial Measurement Unit Insoles
    Riglet, Louis
    Orliac, Baptiste
    Delphin, Corentin
    Leonard, Audrey
    Eby, Nicolas
    Ornetti, Paul
    Laroche, Davy
    Gueugnon, Mathieu
    SENSORS, 2024, 24 (16)
  • [43] Accurate Gait Analysis in Post-Stroke Patients using a Single Inertial Measurement Unit
    Parisi, Federico
    Ferrari, Gianluigi
    Baricich, Alessio
    D'Innocenzo, Marco
    Cisari, Carlo
    Mauro, Alessandro
    2016 IEEE 13TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2016, : 335 - 340
  • [44] Measurement of stride parameters using a wearable GPS and inertial measurement unit
    Tan, Huiling
    Wilson, Alan M.
    Lowe, John
    JOURNAL OF BIOMECHANICS, 2008, 41 (07) : 1398 - 1406
  • [45] Kinematics of lower limb segment movement during gait in a healthy population aged 18 to 97 using inertial measurement units
    Monda, Maureen
    Richards, Rosie
    Smith, April-Louise
    Thornton, Matt
    McCarthy, Ian
    JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2012, 20 : S256 - S257
  • [46] The importance of inertial measurement unit placement in assessing upper limb motion
    Hoglund, Gustav
    Grip, Helena
    Ohberg, Fredrik
    MEDICAL ENGINEERING & PHYSICS, 2021, 92 : 1 - 9
  • [47] Concurrent Validity of the Inertial Measurement Unit Vmaxpro in Vertical Jump Estimation
    Jimenez-Olmedo, Jose M. M.
    Pueo, Basilio
    Mossi, Jose M. M.
    Villalon-Gasch, Lamberto
    APPLIED SCIENCES-BASEL, 2023, 13 (02):
  • [48] Evaluation of spinal posture during gait with inertial measurement units
    Digo, Elisa
    Pierro, Giuseppina
    Pastorelli, Stefano
    Gastaldi, Laura
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2020, 234 (10) : 1094 - 1105
  • [49] Development of a Lower Limb Finite Element Musculoskeletal Gait Simulation Framework Driven Solely by Inertial Measurement Unit Sensors
    Wang, Sentong
    Hase, Kazunori
    Ota, Susumu
    BIOMECHANICS, 2021, 1 (03): : 293 - 306
  • [50] A Novel Approach for Improving Gait Speed EstimationUsing a Single Inertial Measurement Unit Embedded in aSmartphone: Validity and Reliability Study
    Lee, Pei-An
    Yu, Wanting
    Zhou, Junhong
    Tsai, Timothy
    Manor, Brad
    Lo, On-Yee
    JMIR MHEALTH AND UHEALTH, 2024, 12