Electrochemical study of atenolol at a carbon paste electrode modified with mordenite type zeolite

被引:40
|
作者
Arvand, Majid [1 ]
Vaziri, Maryam [1 ]
Vejdani, Maryam [1 ]
机构
[1] Univ Guilan, Dept Chem, Fac Sci, Rasht, Iran
关键词
Atenolol; Mordenite zeolite; Carbon paste electrode; Cyclic voltammetry; Differential pulse voltammetry; PERFORMANCE LIQUID-CHROMATOGRAPHY; SPECTROPHOTOMETRIC DETERMINATION; PHARMACEUTICAL PREPARATIONS; VOLTAMMETRIC DETERMINATION; BETA-BLOCKERS; HUMAN PLASMA; PROPRANOLOL; METOPROLOL; URINE; DRUGS;
D O I
10.1016/j.msec.2010.03.002
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
The electrochemical behavior of atenolol (ATN) at the surface of a carbon paste electrode modified with mordenite zeolite (MOR-MCPE) is described. The prepared electrode shows a good electrocatalytic activity toward the oxidation of atenolol, which is leading to considerable improvement of sensitivity (anodic current). Whereas at the surface of unmodified electrode an electrochemical activity for atenolol cannot be observed, a sharp anodic wave is obtained using the prepared modified electrode. The mechanism of oxidation of ATN at the surface of the MOR-MCPE containing various percents of mordenite is thoroughly investigated by cyclic and differential pulse voltammetry. Acetate, hydrogen phosphate and ammonium buffers were tested as the supporting electrolyte to find the optimal pH value. The optimal pH value was 5.0 for acetate buffer. A linear voltammetric response for ATN was obtained in the concentration range of 0.4 to 80 mu M with a slope of 0.676 mu A/mu M. The LOD and LOQ of the electrode were 0.1 mu M (26.6 mu g/L) and 0.35 mu M (93.1 mu g/L), respectively. The results obtained for ATN in pharmaceutical formulations (tablets) was in agreement with compared reference method. In conclusion, this study has illustrated that the proposed electrode modified with mordenite is suitable for selective measurements of ATN. (c) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:709 / 714
页数:6
相关论文
共 50 条
  • [21] Electrochemical Investigation of Catechol at Poly(niacinamide) Modified Carbon Paste Electrode: A Voltammetric Study
    Teradale, A. B.
    Lamani, S. D.
    Swamy, B. E. Kumara
    Ganesh, P. S.
    Das, S. N.
    ADVANCES IN PHYSICAL CHEMISTRY, 2016,
  • [22] Electrochemical behaviour of carbon paste electrode modified by fibrinogen for biosensors. An impedance study
    ElRhazi, M
    Deslouis, C
    Nigretto, JM
    Frouji, A
    QUIMICA ANALITICA, 1997, 16 : 49 - 53
  • [23] Preparation of Ag/NaA zeolite modified carbon paste electrode as a DNA biosensor
    Azizi, Seyed Naser
    Ranjbar, Sara
    Raoof, Jahan Bakhsh
    Hamidi-Asl, Ezat
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 181 : 319 - 325
  • [24] Voltammetric determination of trace amounts of permanganate at a zeolite modified carbon paste electrode
    Nosuhi, Motahare
    Nezamzadeh-Ejhieh, Alireza
    NEW JOURNAL OF CHEMISTRY, 2017, 41 (24) : 15508 - 15516
  • [25] A zeolite modified carbon paste electrode as useful sensor for voltammetric determination of acetaminophen
    Ahmadpour-Mobarakeh, Leila
    Nezamzadeh-Ejhieh, Alireza
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 49 : 493 - 499
  • [26] Surfactant modified zeolite carbon paste electrode (SMZ-CPE) as a nitrate selective electrode
    Nezamzadeh-Ejhieh, Alireza
    Nematollahi, Zohreh
    ELECTROCHIMICA ACTA, 2011, 56 (24) : 8334 - 8341
  • [27] Imprinted Zeolite Modified Carbon Paste Electrode as a Potentiometric Sensor for Uric Acid
    Khasanah, Miratul
    Widati, Alfa Akustia
    Fitri, Sarita Aulia
    5TH INTERNATIONAL CONFERENCE AND WORKSHOP ON BASIC AND APPLIED SCIENCES (ICOWOBAS 2015), 2016, 1718
  • [28] Studies on Zeolite Modified Electrode(Ⅰ)─Ascorbic Acid Sensor Based on Carbon Paste Electrode Containing Fe(Ⅲ)Y Zeolite
    Ming Zhu ZOU
    Hong Ding XU
    Jie LU
    Qin Hua Ru (a Department of Chemistry
    ChineseChemicalLetters, 1997, (03) : 247 - 250
  • [29] A Gold Nanoparticle-Modified Carbon Paste Electrode as a Sensor for Simultaneous Determination of Acetaminophen and Atenolol
    Behpour, Mohsen
    Ghoreishi, Sayed Mehdi
    Honarmand, Ebrahim
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (12): : 1922 - 1933
  • [30] Carbon Paste Electrode Modified with Biochar for Sensitive Electrochemical Determination of Paraquat
    Kalinke, Cristiane
    Mangrich, Antonio S.
    Marcolino-Junior, Luiz H.
    Bergamini, Marcio F.
    ELECTROANALYSIS, 2016, 28 (04) : 764 - 769