Preoperative cochlear implant imaging: Is magnetic resonance imaging enough?

被引:1
|
作者
Ellul, S
Shelton, C
Davidson, HC
Harnsberger, HR
机构
[1] Univ Utah, Div Otolaryngol Head & Neck Surg, Salt Lake City, UT 84132 USA
[2] Univ Utah, Dept Radiol, Salt Lake City, UT 84132 USA
来源
AMERICAN JOURNAL OF OTOLOGY | 2000年 / 21卷 / 04期
关键词
cochlear implant; magnetic resonance imaging; computed tomography;
D O I
暂无
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective: To investigate the accuracy of magnetic resonance imaging (MRI) as a preoperative imaging technique for cochlear implant candidates. Study Design: Retrospective, blinded. Setting: Tertiary medical center. Patients: 31 cochlear implant candidates with various causes of hearing loss. Intervention: Cochlear implant patients received preoperative high-resolution temporal bone computed tomography (CT), and high-resolution T2-weighted fast spin echo MRI (FSE-MRI). The images were read independently of each other and in a blinded manner by two neuroradiologists. The imaging results were also correlated with intraoperative findings. Main Outcome Measures: Lack of agreement between the findings for either imaging technique; also, lack of agreement between imaging findings and intraoperative findings. Results: FSE-MRI is equal to CT imaging in the detection of abnormalities of cochlear patency, It is better than CT imaging in detecting cochlear dysplasia and large vestibular aqueducts, and in determining the presence of the cochlear nerve. Conclusion: FSE-MRI is accurate in predicting inner ear anomalies and obstruction of the cochlear lumen. It also adds information not gathered from CT imaging, such as the presence and size of the cochlear nerve.
引用
收藏
页码:528 / 533
页数:6
相关论文
共 50 条
  • [41] COCHLEAR IMPLANTS AS A CONTRAINDICATION TO MAGNETIC-RESONANCE-IMAGING
    PORTNOY, WM
    MATTUCCI, K
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1991, 100 (03): : 195 - 197
  • [42] Preoperative imaging assessment of cochlear implant candidates: the integrative role of MDCT and MRI
    Daqqaq, Tareef S.
    Almoghthwey, Talal H.
    Radwan, Moustafa E.
    Hkeem, Feras, I
    Alahmadi, Hasan S.
    El Kady, Reem M.
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2021, 14 (08): : 2164 - 2172
  • [43] Preoperative Imaging Findings and Cost in Adults With Postlingual Deafness Prior to Cochlear Implant
    Brown, C. Scott
    Choi, Kevin J.
    Kaylie, David M.
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2018, 127 (04): : 270 - 274
  • [44] MAGNETIC-RESONANCE IMAGING (MRI) AND HIGH-RESOLUTION COMPUTERTOMOGRAPHY (HRCT) IN COCHLEAR IMPLANT CANDIDATES
    LASZIG, R
    TERWEY, B
    BATTMER, RD
    HESSE, G
    SCANDINAVIAN AUDIOLOGY, 1988, : 197 - 200
  • [45] COMPUTED-TOMOGRAPHY AND MAGNETIC-RESONANCE-IMAGING IN THE PREOPERATIVE WORK-UP FOR COCHLEAR IMPLANTATION
    KLEIN, HM
    BOHNDORF, K
    HERMES, H
    SCHUTZ, WF
    GUNTHER, RW
    SCHLONDORFF, G
    EUROPEAN JOURNAL OF RADIOLOGY, 1992, 15 (01) : 89 - 92
  • [46] Magnetic resonance imaging cognitive fusion biopsy - is near enough good enough?
    Sathianathen, Niranjan J.
    Christidis, Daniel
    Konety, Badrinath R.
    Lawrentschuk, Nathan L.
    BJU INTERNATIONAL, 2018, 121 (03) : 324 - 326
  • [47] Magnetic resonance imaging to diagnose breast implant rupture
    Wedler V.
    Meuli-Simmen C.
    Kubik-Huch R.A.
    Künzi W.
    Meyer V.
    European Journal of Plastic Surgery, 2002, 25 (5) : 247 - 252
  • [48] Breast implant evaluation: Pitfall of magnetic resonance imaging
    Abenavoli, FM
    Corelli, R
    Giordano, L
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 111 (01) : 507 - 508
  • [49] Magnetic Resonance Imaging Characteristics of a Baerveldt Glaucoma Implant
    Anderson, Daniel M.
    Schwope, Ryan B.
    Reiter, Michael J.
    Suhr, Abraham W.
    JOURNAL OF GLAUCOMA, 2017, 26 (06) : 534 - 540
  • [50] Imaging spectrum of breast implant complications: Mammography, ultrasound, and magnetic resonance imaging
    O'Toole, M