The Micro-Flow Reaction System Featured the Liquid-Liquid Interface Created with Ternary Mixed Carrier Solvents in a Capillary Tube

被引:11
|
作者
Masuhara, Yuji [1 ]
Jinno, Naoya [1 ]
Hashimoto, Masahiko [1 ]
Tsukagoshi, Kazuhiko [1 ]
机构
[1] Doshisha Univ, Fac Sci & Engn, Dept Chem Engn & Mat Sci, Kyoto 6100321, Japan
关键词
RADIAL-DISTRIBUTION PHENOMENON; HYDRODYNAMIC CHROMATOGRAPHY; SEPARATION; PROTEIN; DEVICES; ELECTROPHORESIS;
D O I
10.2116/analsci.28.439
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A micro-flow reaction system was developed in which liquid-liquid interface was created based on the tube radial distribution of ternary mixed carrier solvents. The system was constructed from double capillary tubes having different inner diameters (100 and 250 mu m i.d.). The smaller tube was inserted into the larger one through a T-type joint. The reaction of a protein with a fluorescence derivatizing reagent was adopted as a model. A water-acetonitrile mixture (3:1 volume ratio) including bovine serum albumin (hydrophilic) was delivered into the large tube from the inside through the small tube and an acetonitrile-ethyl acetate mixture (7:4 volume ratio) containing fluorescamine (hydrophobic) as a derivatizing reagent was delivered from the outside through the joint. Solutions were mixed through the double capillary tubes to promote ternary mixed carrier solvents (water-acetonitrile-ethyl acetate; 1:2:1 volume ratio). The liquid-liquid interface was created based on the tube radial distribution of ternary solvents in the larger tube. The derivatization reaction was performed in the larger, or reaction, tube in the micro-flow system. The fluorescence intensity of the fluorescamine-derivatized bovine serum albumin obtained by the system, which specifically included the kinetic liquid-liquid interface in the tube, was greater than that obtained through a batch reaction using a homogeneous solution of water-acetonitrile (1:2 volume ratio).
引用
收藏
页码:439 / 444
页数:6
相关论文
共 50 条
  • [31] Micro-channel Chemiluminescence Analysis Using a Peroxyoxalate Reaction that Works through Liquid-Liquid Interface Collapse under Laminar-Flow Conditions
    Kazuhiko Tsukagoshi
    Yoshiyuki Hattori
    Teruki Hayashi
    Riichiro Nakajima
    Kenichi Yamashita
    Hideaki Maeda
    Analytical Sciences, 2008, 24 : 1393 - 1398
  • [32] Liquid-liquid equilibria for the ternary system of water plus furfural plus solvents at 303.15 and 323.15 K under atmospheric pressure
    Cui, Peng
    Liu, Hai
    Xin, Kun
    Yan, Houchun
    Xia, Qing
    Huang, Yunjing
    Li, Qingsong
    JOURNAL OF CHEMICAL THERMODYNAMICS, 2018, 127 : 134 - 144
  • [33] Interface tracking simulation of immiscible two-phase flow in liquid-liquid dispersion atomization system
    Liang, Kunfeng
    Jia, Xueying
    Gao, Chunyan
    Yuan, Zhulin
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2015, 46 (06): : 363 - 371
  • [34] Experimental Consideration of Capillary Chromatography Based on Tube Radial Distribution of Ternary Mixture Carrier Solvents under Laminar Flow Conditions
    Naoya Jinno
    Masahiko Hashimoto
    Kazuhiko Tsukagoshi
    Analytical Sciences, 2011, 27 : 259 - 264
  • [35] The flow behavior of droplet adsorption on a liquid-liquid interface accompanied by cross-linking reaction and phase separation in a microchannel
    Haozhe Yi
    Taotao Fu
    Chunying Zhu
    Youguang Ma
    Chinese Journal of Chemical Engineering, 2024, 66 (02) : 60 - 70
  • [36] The flow behavior of droplet adsorption on a liquid-liquid interface accompanied by cross-linking reaction and phase separation in a microchannel
    Yi, Haozhe
    Fu, Taotao
    Zhu, Chunying
    Ma, Youguang
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2024, 66 : 60 - 70
  • [37] Experimental Consideration of Capillary Chromatography Based on Tube Radial Distribution of Ternary Mixture Carrier Solvents under Laminar Flow Conditions
    Jinno, Naoya
    Hashimoto, Masahiko
    Tsukagoshi, Kazuhiko
    ANALYTICAL SCIENCES, 2011, 27 (03) : 259 - 264
  • [38] Liquid-liquid equilibrium data for the ternary system based on ionic liquid plus organic solvents + water at 298 K and atmospheric pressure applied in antidepressant partitioning
    de Sousa, Kenia Marcatti
    Pereira Lima, Thailan Souza
    de Souza, Ranyere Lucena
    Beatriz Nerli, Bibiana
    Pereira, Matheus M.
    Faria Soares, Cleide Mara
    Lima, Alvaro Silva
    SEPARATION AND PURIFICATION TECHNOLOGY, 2022, 278
  • [39] Use of tube radial distribution of ternary mixed carrier solvents for introduction of absorption reagent for metal ion separation and online detection into capillary
    Fujinaga, Satoshi
    Jinno, Naoya
    Hashimoto, Masahiko
    Tsukagoshi, Kazuhiko
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (20) : 2833 - 2839
  • [40] Wetting-Induced Water Promoted Flow on Tunable Liquid-Liquid Interface-Based Nanopore Membrane System
    Wu, Yadong
    Ling, Haoyang
    Qian, Yongchao
    Hu, Yuhao
    Niu, Bo
    Lin, Xiangbin
    Kong, Xiang-Yu
    Jiang, Lei
    Wen, Liping
    ACS NANO, 2022, 16 (07) : 11092 - 11101