Poly-xanthurenic acid modified electrodes: An amperometric sensor for the simultaneous determination of ascorbic and uric acids

被引:31
|
作者
dos Santos Silva, Francisco de Assis [1 ,4 ]
Lopes, Cleylton Bezerra [1 ,2 ,4 ]
Kubota, Lauro Tatsuo [3 ,4 ]
Lima, Phabyanno Rodrigues [1 ,2 ,4 ]
Fonseca Goulart, Marilia Oliveira [1 ,4 ]
机构
[1] Univ Fed Alagoas, Inst Quim & Biotecnol, BR-57072970 Maceio, AL, Brazil
[2] IFAL, Inst Fed Educ Ciencia & Tecnol Alagoas, BR-57020600 Maceio, AL, Brazil
[3] Univ Estadual Campinas, Inst Quim, BR-13084971 Campinas, SP, Brazil
[4] Univ Estadual Campinas, Inst Nacl Ciencia & Tecnol Bioanalit, BR-13084971 Campinas, SP, Brazil
来源
关键词
Xanthurenic acid; MWCNT; Ascorbic acid; Uric acid; Electrocatalysis; Chemically modified electrodes; WALL CARBON NANOTUBES; ELECTROCATALYTIC OXIDATION; PASTE ELECTRODE; HOMOCYSTEINE; DISPERSION; NADH;
D O I
10.1016/j.snb.2012.04.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The poly-xanthurenic acid (poly-Xa)/multi-walled carbon nanotube (MWCNT)/glassy carbon modified electrode (poly-Xa/MWCNT/GCE) was successfully applied for the simultaneous determination of ascorbic (AA) and uric (UA) acids. Cyclic voltammetric results show that the modified electrode displays an excellent eletrocatalytic activity toward the oxidation of AA at a low potential (0.05 V versus Ag/AgCl) and anodic peak resolution (Delta E-pa), close to 300 mV versus Ag/AgCl, in solutions containing AA and UA. Values in the order of 10(6) L mol(-1) s(-1) were obtained for the kinetic constant k(cat) for the catalytic oxidation of AA, upon evaluation by cyclic voltammetry, chronoamperometry and RDE. Furthermore, the sensor provided limits of detection of 0.19 mu mol L-1 and 0.31 mu mol L-1 for AA and UA, respectively. The sensor was applied for the simultaneous determination of AA and UA in urine samples and the average recoveries for these samples were 99.9 (+/-2.5)% and 99.9 (+/-2.6)%, respectively. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:289 / 296
页数:8
相关论文
共 50 条
  • [41] Poly(thionine)-modified GC Electrode for Simultaneous Detection of Dopamine and Uric Acid in the Presence of Ascorbic Acid
    Yuan, Yong
    Ahammad, A. J. Saleh
    Xu, Guang-Ri
    Kim, Sunghyun
    Lee, Jae-Joon
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2008, 29 (10) : 1883 - 1884
  • [42] Poly(thionine)-modified GC electrode for simultaneous detection of dopamine and uric acid in the presence of ascorbic acid
    Yuan, Yong
    Ahammad, A. J. Saleh
    Xu, Guang-Ri
    Kim, Sunghyun
    Lee, Jae-Joon
    1883, Korean Chemical Society, Seoul, 135-703, South Korea (29)
  • [43] Simultaneous Electroanalysis of Norepinephrine, Ascorbic Acid and Uric Acid at Poly(niacinamide) Modified Carbon Paste Electrode
    Ganesh, Pattan Siddappa
    Swamy, Bahaddurghatta Eshwaraswamy Kumara
    Teradale, Amit Balasab
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (05): : 612 - 630
  • [44] Selective voltammetric determination of uric acid in the presence of ascorbic acid at ordered mesoporous carbon modified electrodes
    Wen Yan-Li
    Jia Neng-Qin
    Wang Zhi-Yong
    Shen He-Bai
    CHINESE JOURNAL OF CHEMISTRY, 2008, 26 (06) : 1052 - 1056
  • [45] Silver Doped Poly(L-valine) Modified Glassy Carbon Electrode for the Simultaneous Determination of Uric Acid, Ascorbic Acid and Dopamine
    Hu, Wenna
    Sun, Dengming
    Ma, Wei
    ELECTROANALYSIS, 2010, 22 (05) : 584 - 589
  • [46] Simultaneous determination of ascorbic acid, epinephrine and uric acid at over-oxidized poly(p-aminophenol) film modified electrode
    Kocak, Cagri Ceylan
    Dursun, Zekerya
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 694 : 94 - 103
  • [47] Simultaneous electrochemical determination of dopamine, ascorbic acid and uric acid using poly(acid chrome blue K) modified glassy carbon electrode
    Zhang, Rui
    Jin, Gen-Di
    Chen, Da
    Hu, Xiao-Ya
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 138 (01): : 174 - 181
  • [48] Simultaneous determination of ascorbic acid, dopamine and uric acid using poly(L-leucine)/DNA composite film modified electrode
    Zheng, Xinyu
    Guo, Yuheng
    Zheng, Jinshuai
    Zhou, Xuechou
    Li, Qinglu
    Lin, Ruiyu
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 213 : 188 - 194
  • [49] Poly(pyridine-3-boronic acid)/Multiwalled Carbon Nanotubes Modified Glassy Carbon Electrodes for Simultaneous Determination of Ascorbic Acid, 3,4-Dihydroxyphenylacetic Acid and Uric Acid
    Wu, Zhijiao
    Zhao, Hong
    Xue, Ying
    He, Yujian
    Li, Xiangjun
    Yuan, Zhuobin
    ELECTROANALYSIS, 2010, 22 (19) : 2196 - 2201
  • [50] Electrochemical characterization of poly(fuchsine acid) modified glassy carbon electrode and its application for simultaneous determination of ascorbic acid, epinephrine and uric acid
    Taei, M.
    Hasanpour, F.
    Tavakkoli, N.
    Bahrameian, M.
    JOURNAL OF MOLECULAR LIQUIDS, 2015, 211 : 353 - 362