Repeated sensor use for regional cerebral oxygenation measurements by near-infrared spectroscopy: a technical report

被引:0
|
作者
Ancona, Paolo [1 ]
Eyeington, Christopher T. [1 ]
Cutuli, Salvatore L. [1 ]
Glassford, Neil J. [1 ,2 ]
Eastwood, Glenn M. [1 ,2 ]
Bellomo, Rinaldo [1 ,2 ,3 ]
机构
[1] Austin Hosp, Dept Intens Care, Melbourne, Vic, Australia
[2] Monash Univ, Australian & New Zealand Intens Care Res Ctr, Sch Publ Hlth & Prevent Med, Melbourne, Vic, Australia
[3] Univ Melbourne, Sch Med, Melbourne, Vic, Australia
关键词
CARDIAC-ARREST; SATURATION; CHILDREN; NIRS;
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Near-infrared spectroscopy (NIRS) has been used in clinical practice to assess regional cerebral tissue oxygen saturation (Stco(2)). There is no evidence whether repeated use of the same sensor affects Stco(2) measurements. We aimed to assess whether there was a significant systematic decrease or increase in Stco(2) when NIRS sensors were reused. Design: Participants were divided into three groups (A, B and C). Stco(2) was recorded over 5 minutes daily for 5 days in Groups A and B ("new-sensor" [NS] period; sensor age, 1-5 days) and in Groups A and C, with the sensor previously used for A ("extended-use" [EU] period; sensor age, 6-10 days). Setting: Single-centre, university hospital, intensive care unit. Participants: Healthy volunteers. Main outcome measures: Stco(2) change within and between study periods. Results: In 13 participants (9 male; median age, 30 years), the range of median Stco2 values per day was 65-72%. In the NS period, there were no changes in right-sided Stco(2), and left-sided Stco(2) showed no systematic or progressive patterns of increase or decrease when comparing Day 1 with subsequent days. There were no differences when comparing Day 1 with subsequent days (up to Day 10) in the EU period or between the NS and EU periods for left or right Stco(2). Conclusions: Repeated use of NIRS sensors measured Stco(2) in different individuals for up to 10 days. There were no significant, systematic, persistent or progressive changes in Stco(2) with extended use over time. Our findings suggest that Stco(2) does not change with sensor reuse for up to 10 days.
引用
收藏
页码:164 / 167
页数:4
相关论文
共 50 条
  • [31] Quantitative measurements of cerebral blood flow with near-infrared spectroscopy
    Pham, Thao
    Tgavalekos, Kristen
    Sassaroli, Angelo
    Blaney, Giles
    Fantini, Sergio
    [J]. BIOMEDICAL OPTICS EXPRESS, 2019, 10 (04) : 2117 - 2134
  • [32] Regional cerebral oxygenation measured by multichannel near-infrared spectroscopy (optical topography) in an infant supported on venoarterial extracorporeal membrane oxygenation
    Papademetriou, Maria D.
    Tachtsidis, Ilias
    Banaji, Murad
    Elliott, Martin J.
    Hoskote, Aparna
    Elwell, Clare E.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 141 (05): : E31 - E33
  • [33] NEAR-INFRARED MONITORING OF CEREBRAL OXYGENATION IN NEONATES
    COPE, M
    DELPY, DT
    WYATT, JS
    WRAY, S
    REYNOLDS, EOR
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1987, 8 (04): : 394 - 394
  • [34] Cerebral oxygenation as measured by near-infrared spectroscopy in neonatal intensive care: correlation with arterial oxygenation
    Hunter, Carol Lu
    Oei, Ju Lee
    Lui, Kei
    Schindler, Timothy
    [J]. ACTA PAEDIATRICA, 2017, 106 (07) : 1073 - 1078
  • [35] Cerebral oxygenation state in childhood moyamoya disease: A near-infrared spectroscopy study
    Lin, YP
    Yoshiko, K
    Negoro, T
    Watanabe, K
    Negoro, M
    [J]. PEDIATRIC NEUROLOGY, 2000, 22 (05) : 365 - 369
  • [36] MONITORING OF CEREBRAL OXYGENATION USING NEAR-INFRARED SPECTROSCOPY DURING CAROTID ENDARTERECTOMY
    MASON, PF
    BEARD, JD
    [J]. BRITISH JOURNAL OF SURGERY, 1994, 81 (12) : 1805 - 1806
  • [37] Cerebral and Lower Limb Near-Infrared Spectroscopy in Adults on Extracorporeal Membrane Oxygenation
    Wong, Joshua K.
    Smith, Thomas N.
    Pitcher, Harrison T.
    Hirose, Hitoshi
    Cavarocchi, Nicholas C.
    [J]. ARTIFICIAL ORGANS, 2012, 36 (08) : 659 - 667
  • [39] Cerebral Oxygenation by Near-Infrared Spectroscopy in Infants Undergoing Thoracoscopic Lung Resection
    Franzini, Stefania
    Morandi, Anna
    Palmisani, Francesca
    Consonni, Dario
    Macchini, Francesco
    Calderini, Edoardo
    Leva, Ernesto
    [J]. JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2021, 31 (09): : 1084 - 1091
  • [40] Evaluation of brain oxygenation during selective cerebral perfusion by near-infrared spectroscopy
    Katoh, T
    Esato, K
    Gohra, H
    Hamano, K
    Fujimura, Y
    Zempo, N
    Nakashima, K
    Maekawa, T
    [J]. ANNALS OF THORACIC SURGERY, 1997, 64 (02): : 432 - 436