PLL Less Shunt Active Filter with Direct Current Control for Power Quality Conditioning

被引:0
|
作者
Gupta, Nitin [1 ]
Singh, S. P. [1 ]
Dubey, S. P. [1 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Roorkee 247667, Uttar Pradesh, India
关键词
Active filter; direct current control; harmonics; neural network; hysteresis current contoller; power qaulity; HARMONICS; COMPENSATION;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, a novel neural network based phase locked loop (PLL) less reference current computation method for active power filter (APF) control under non-ideal mains voltage conditions with different load condition is proposed. The neural network controller comprises two similar adaptive linear neurons (ADALINE), and it has been designed to extract fundamental frequency components from non-sinusoidal and unbalanced currents. The compensation process is based on sensing source currents only, without sensing source voltage and load currents, which gives more simplicity in control with less number of sensors. The APF realized by a current controlled IGBT based PWM-VSI bridges with a common dc bus capacitor. The proposed neural network compensation approach has been evaluated in simulations. The results show excellent performance, as well as robustness
引用
收藏
页码:371 / 376
页数:6
相关论文
共 50 条
  • [21] Analysis and experimental evaluation of shunt active power filter for power quality improvement based on predictive direct power control
    Oualid Aissa
    Samir Moulahoum
    Ilhami Colak
    Badreddine Babes
    Nadir Kabache
    Environmental Science and Pollution Research, 2018, 25 : 24548 - 24560
  • [22] Delay loop current control methods of Shunt Active Power Filter
    Liu, Gui-ying
    Su, Shi-ping
    MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION IV, PTS 1 AND 2, 2012, 128-129 : 105 - 108
  • [23] Intelligent Control of Shunt Active Power Filter for Minimization of Current Harmonics
    Raheni, T. D.
    Thirumoorthi, P.
    TENCON 2017 - 2017 IEEE REGION 10 CONFERENCE, 2017, : 2846 - 2851
  • [24] Shunt active power filter with harmonic current control strategy.
    Doval, J
    Nogueiras, A
    Peñalver, CM
    Lago, A
    PESC 98 RECORD - 29TH ANNUAL IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1 AND 2, 1998, : 1631 - 1635
  • [25] Double hysteresis current control strategy for shunt active power filter
    Electric Power College, South China University of Technology, Guangzhou 510640, China
    不详
    Dianli Xitong Baohu yu Kongzhi, 2009, 9 (60-64):
  • [26] Current Loop Control Strategy Research for Shunt Active Power Filter
    Chen Yuqing
    Zhang Kehu
    Ji Zhaojun
    Zhen Hongfen
    Kong Feng
    2009 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-3, 2009, : 698 - +
  • [27] The Research on Stability of Deadbeat Current Control in Shunt Active Power Filter
    Li, Chunlong
    Guo, Baoping
    Li, Nan
    2009 IEEE 6TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2009, : 1653 - +
  • [28] Fuzzy Logic Control of Shunt Active Power Filter for Power Quality Improvement
    Anjana, S.
    Maya, P.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON SOFT COMPUTING SYSTEMS, ICSCS 2015, VOL 1, 2016, 397 : 975 - 985
  • [30] Adaptive Hysteresis Current Controlled Shunt Active Power Filter for Power Quality Enhancement
    Thekkath, Preethi
    Prabha, S. U.
    PROCEEDINGS OF 2013 INTERNATIONAL CONFERENCE ON CIRCUITS, POWER AND COMPUTING TECHNOLOGIES (ICCPCT 2013), 2013, : 31 - 36