X-ray Telescope Mirror Mounting and Deformation Reduction Using ThermoYield Actuators and Mirror Geometry Changes

被引:3
|
作者
DeTienne, Michael D. [1 ,2 ]
Bruccoleri, Alexander R. [1 ]
Molnar-Fenton, Anjelica [1 ]
Chalifoux, Brandon [2 ]
Heilmann, Ralf K. [2 ]
Yao, Youwei [2 ]
Schattenburg, Mark L. [2 ]
机构
[1] Izentis LLC, POB 397002, Cambridge, MA 02139 USA
[2] MIT, Space Nanotechnol Lab, 70 Vassar St, Cambridge, MA 02139 USA
关键词
Adjustable; set-and-forget; X-ray telescope; segmented optics; X-ray mirror; optical mount; stress localization;
D O I
10.1117/12.2314896
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Recently, the X-ray optics community has been developing technology for high angular resolution, large collecting area X-ray telescopes such as the Lynx mission concept. To meet the high collecting area requirements of such telescope concepts, research is being conducted on thin, segmented optics. The precision mounting posts that fixture and align segmented optics must be the correct length to sub-micron accuracy to satisfy the angular resolution goals of such a concept. Mirror distortion caused by adhesive shrinkage at mount points on the mirror surface also needs to be controlled to micron-radian tolerances. We report on two solutions to these problems. Set-and-forget adjustable length optical mounting posts have been developed to control mirror spacer length. The actuator consists of a metal cylinder with a cylindrical neck cut halfway along the length. To change the length of this actuator, an axial force is applied and the neck is momentarily heated to the plastic deformation temperature via resistive heating. All of the plastic deformation that occurs becomes permanent after cooling. Both compression and expansion of these actuators has been demonstrated in steps ranging from 6 nm to several microns. This paper will describe an experimental setup, show, and discuss data. Additionally, a stress relief technique to reduce mirror distortion caused by shrinkage of the adhesive bond to the actuator is proposed and demonstrated by modelling.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] An application of space technology to the terrestrial search for axions:: the X-ray mirror telescope at CAST
    Lutz, G
    Bräuninger, H
    Englhauser, J
    Hartmann, R
    Kang, D
    Kotthaus, R
    Kuster, M
    Serber, W
    Strüder, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2): : 201 - 206
  • [32] DESIGN AND ANALYSIS OF A 2-CHANNEL 3-MIRROR X-RAY TELESCOPE
    KASSIM, AM
    SHEALY, DL
    APPLIED OPTICS, 1984, 23 (19): : 3482 - 3486
  • [33] DESIGN AND ANALYSIS OF A 2-CHANNEL 3-MIRROR X-RAY TELESCOPE
    KASSIM, AM
    SHEALY, DL
    APPLIED OPTICS, 1984, 23 (16): : 2697 - 2701
  • [34] Wolter-I-like X ray telescope structure using one conical mirror and one quadric mirror
    陈晟昊
    马爽
    王占山
    Chinese Optics Letters, 2016, 14 (12) : 156 - 160
  • [35] Wolter-I-like X ray telescope structure using one conical mirror and one quadric mirror
    Chen, Shenghao
    Ma, Shuang
    Wang, Zhanshan
    CHINESE OPTICS LETTERS, 2016, 14 (12)
  • [36] Focusing of soft X-ray using a grazing incidence mirror
    Hayashi, Y
    Taniguchi, H
    Gohmi, H
    Sakamoto, N
    Watanabe, M
    Okino, A
    Shiho, M
    Horioka, K
    Hotta, E
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2004, 43 (03): : 1166 - 1167
  • [37] Using refractive optics to broaden the focus of an X-ray mirror
    Laundy, David
    Sawhney, Kawal
    Dhamgaye, Vishal
    JOURNAL OF SYNCHROTRON RADIATION, 2017, 24 : 744 - 749
  • [38] X-ray mirror figure correction using differential deposition
    Morawe, Ch
    Laboure, S.
    Perrin, F.
    Vivo, A.
    Barrett, R.
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS XIX, 2024, 13150
  • [39] A simple X-ray focusing mirror using float glass
    Yin, Z
    Berman, L
    Dierker, S
    Dufresne, E
    Siddons, DP
    OPTICS FOR HIGH-BRIGHTNESS SYNCHROTRON RADIATION BEAMLINES II, 1996, 2856 : 307 - 313
  • [40] MICROSCOPIC X-RAY PHOTOELECTRON-SPECTROSCOPY USING A WOLTER TYPE X-RAY MIRROR
    NINOMIYA, K
    HASEGAWA, M
    AOKI, S
    SUZUKI, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1991, 30 (11A): : 2889 - 2894