Serious complications following endovascular thoracic aortic stent-graft repair for type B dissection

被引:148
|
作者
Neuhauser, Beate [1 ]
Greiner, Andreas [1 ]
Jaschke, Werner [2 ]
Chemelli, Andreas [2 ]
Fraedrich, Gustav [1 ]
机构
[1] Univ Innsbruck Hosp, Dept Vasc Surg, A-6020 Innsbruck, Austria
[2] Univ Innsbruck Hosp, Dept Radiol, A-6020 Innsbruck, Austria
关键词
endovascular thoracic aortic repair; severe complication; type B dissection;
D O I
10.1016/j.ejcts.2007.10.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To describe our experience with endovascular stent-graft repairs in type B aortic dissection focusing on serious secondary complications resulting in immediate or late conversion to open repair. Methods: From November 1997 to May 2007, 28 patients underwent a thoracic endovascular stent-graft procedure for acute symptomatic type B dissection at our institution. Indication for endovascular repair at our department is a complicated course of type B dissection, including thoracic aortic rupture, suspicion of impending rupture, visceral. and/or peripheral ischemia, uncontrollable hypertension, and severe therapy-resistant pain. Median follow-up time was 48.3 months (range 2-97 months). Results: Secondary complications with indication for a secondary intervention occurred in 5/28 patients, resulting in additional procedures in 4 patients. One patient declined any further therapy. Conversion to an open procedure was performed in four patients, one due to type I endoleak followed by retrograde type A dissection, and three due to retrograde type A dissection. One of these patients had an additional stent-graft procedure performed due to a type III endoleak 20 months post stent grafting. Retrograde type A dissection occurred 39 months later, finally leading to conversion to an open procedure. Open surgery was performed in four patients after 3, 26, 29, and 1170 days post stent-graft placement and was successful in three patients. The fourth patient died 3 months post-surgically due to multi-organ failure. The procedure-related mortality rate following secondary complications was (1/5) 20%. Conclusions: Endovascular stent-graft repair of the thoracic aorta is an alternative to surgical repair, however not without significant morbidity and mortality. Potentially lethal complications, acute or delayed, may occur. (C) 2007 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:58 / 63
页数:6
相关论文
共 50 条
  • [41] Thoracic Aortic Pseudoaneurysm Following Endovascular Stent Graft Placement for Treatment of Type B Dissection: What causes it?
    Janosi, Rolf Alexander
    Bettin, Markus
    Konorza, Thomas
    Eggebrecht, Holger
    Erbel, Raimund
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B37 - B37
  • [42] Endoluminal stent-graft stabilization for thoracic aortic dissection
    Nathanson, DR
    Rodriguez-Lopez, JA
    Ramaiah, VG
    Williams, J
    Olsen, DM
    Wheatley, GH
    Diethrich, EB
    JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 (03) : 354 - 359
  • [43] Development of new endovascular stent-graft system for type B thoracic aortic dissection with finite element analysis and experimental verification
    Xiaochen Zhou
    Fan Yang
    Xiaoyan Gong
    Ming Zhao
    Yufeng Zheng
    Zhili Sun
    Journal of Materials Science & Technology, 2019, 35 (11) : 2682 - 2692
  • [44] A graft inversion technique for retrograde type A aortic dissection after thoracic endovascular repair for type B aortic dissection
    Wenbin Hu
    Yiran Zhang
    Lei Guo
    Jingya Fan
    Yuan Lu
    Liang Ma
    Journal of Cardiothoracic Surgery, 14
  • [45] Virtual Angioscopy in type A dissection: Ascending aortic stent-graft repair
    Verhoye, JP
    Sze, DY
    Ihnken, K
    Hellinger, JC
    Robbins, RR
    Dake, MD
    ANNALS OF THORACIC SURGERY, 2006, 82 (01): : 347 - 347
  • [46] A graft inversion technique for retrograde type A aortic dissection after thoracic endovascular repair for type B aortic dissection
    Hu, Wenbin
    Zhang, Yiran
    Guo, Lei
    Fan, Jingya
    Lu, Yuan
    Ma, Liang
    JOURNAL OF CARDIOTHORACIC SURGERY, 2019, 14 (1)
  • [47] Aortic Remodeling in Type B Aortic Dissection: Effects of Endovascular Stent-Graft Repair and Medical Treatment on True and False Lumen Volumes
    Huptas, Sebastian
    Mehta, Rajendra H.
    Kuehl, Hilmar
    Tsagakis, Konstantinos
    Reinsch, Nico
    Kahlert, Philipp
    Jakob, Heinz G.
    Erbel, Raimund
    Eggebrecht, Holger
    JOURNAL OF ENDOVASCULAR THERAPY, 2009, 16 (01) : 28 - 38
  • [48] Development of new endovascular stent-graft system for type B thoracic aortic dissection with finite element analysis and experimental verification
    Zhou, Xiaochen
    Yang, Fan
    Gong, Xiaoyan
    Zhao, Ming
    Zheng, Yufeng
    Sun, Zhili
    JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2019, 35 (11) : 2682 - 2692
  • [49] Outcomes of thoracic endovascular aortic repair with fenestrated surgeon-modified stent-graft for type B aortic dissections involving the aortic arch
    Li, Xiaoye
    Zhang, Lei
    Song, Chao
    Zhang, Hao
    Xia, Shibo
    Yang, Yang
    Zhu, Longtu
    Guo, Wenying
    Lu, Qingsheng
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 9
  • [50] Dislocation of a stent-graft into the aortic arch during endovascular repair of a descending thoracic aortic aneurysm
    Augustin, N
    Bauernschmitt, R
    Hausleiter, J
    Lange, R