Transcutaneous monitoring as a replacement for arterial PCO2 monitoring during nocturnal non-invasive ventilation

被引:91
|
作者
Storre, Jan Hendrik [1 ]
Magnet, Friederike Sophie [1 ]
Dreher, Michael [1 ]
Windisch, Wolfram [1 ]
机构
[1] Univ Hosp Freiburg, Dept Pneumol, D-79106 Freiburg, Germany
关键词
Alveolar ventilation; Carbon dioxide; Monitoring; Nocturnal ventilation; Sleep; Transcutaneous pressure of carbone dioxid; STABLE HYPERCAPNIC COPD; POSITIVE-PRESSURE VENTILATION; CHRONIC RESPIRATORY-FAILURE; RANDOMIZED CROSSOVER TRIAL; CARBON-DIOXIDE; MECHANICAL VENTILATION; CRITICALLY-ILL; CLINICAL-EVALUATION; NASAL VENTILATION; HIGH-INTENSITY;
D O I
10.1016/j.rmed.2010.10.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Continuous, non-invasive assessment of alveolar ventilation achieved by transcutaneous PCO2 (PtcCO(2)) monitoring is clearly superior to intermittent, invasive blood gas analyses in patients receiving nocturnal non-invasive positive pressure ventilation (NPPV), but the reliability and accuracy of PtcCO(2)-monitoring is still disputed. The present study was aimed at investigating the capability of modern PtcCO(2)-monitoring to reliably assess alveolar ventilation during nocturnal NPPV. Methods: Capillary blood gas measurements (11pm, 2am, 5am and 7am) and 8 h of continuous PtcCO(2)-monitoring using three of the latest generation devices (SenTec Digital Monitor, Radiometer TCM4-TINA and Radiometer TOSCA500) were performed during polysomnography-proven sleep studies in 24 patients receiving NPPV (15 with COPD, 9 with restrictive disorders). Results: The technical calibration drift for SenTec DM, TCM4-TINA and TOSCA500 was 0.1, -0.4 and -0.5 mmHg/h, respectively. Bland-Altman method comparison of PaCO2/drift-uncorrected PtcCO(2) revealed a mean bias (limits of agreement) of 1.0 (-4.7 to 6.7), -1.5 (-15.6 to 12.5) and 0.8 (-6.8 to 8.3) mmHg, respectively. Continuous overnight PtcCO(2)-monitoring detected variations in alveolar ventilation, with median ranges of 12.3 (10.7-14.5) mmHg for SenTec DM, 14.5 (12.5-17.0) mmHg for TCM4-TINA and 11.5 (11.0-13.0) mmHg for TOSCA500 (RM-ANOVA, p < 0.001). The four capillary PaCO2 values ranged by a median of 6.3 (4.7-9.7) mmHg. Conclusions: Modern PtcCO(2)-monitoring is reliable, accurate and robust. Since PtcCO(2)-monitoring is also non-invasive, does not disrupt sleep quality and provides a more complete picture of alveolar ventilation than intermittent capillary PaCO2, PtcCO(2)-monitoring should become the preferred technique for assessing alveolar ventilation during nocturnal NPPV. Trial Registration: DRKS00000433 at http://apps.who.int/trialsearch/default.aspx. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 50 条
  • [41] Acute COPD: Critical Monitoring during non-invasive Ventilation
    Pfeifer, M.
    [J]. MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2016, 111 (03) : 183 - 183
  • [42] Non-invasive two-point estimation of arterial PCO2 and alveolar deadspace
    E Michel
    JA Peper
    [J]. Critical Care, 4 (Suppl 1):
  • [43] CUTANEOUS PCO2 MONITORING AND ARTIFICIAL-VENTILATION IN THE NEWBORN
    ERNY, P
    MESSER, J
    WILLARD, D
    [J]. INTENSIVE CARE MEDICINE, 1981, 7 (05) : 252 - 253
  • [44] Transcutaneous PO2 and PCO2 monitoring for flap transplanted in microsurgery
    Hashimoto, I
    Nakanishi, H
    [J]. PROCEEDINGS OF THE INAUGURAL CONGRESS OF THE WORLD SOCIETY FOR RECONSTRUCTIVE MICROSURGERY, 2001, : 21 - 22
  • [45] Transcutaneous Pco2 Monitoring in. Newborn Infants During General Anesthesia Is Technically Feasible
    Karlsson, Victoria
    Sporre, Bengt
    Agren, Johan
    [J]. ANESTHESIA AND ANALGESIA, 2016, 123 (04): : 1004 - 1007
  • [46] Response to Re: Agreement between arterial and venous pH and pCO2 in patients undergoing non-invasive ventilation in the emergency department
    Kelly, Anne-Maree
    [J]. EMERGENCY MEDICINE AUSTRALASIA, 2013, 25 (06) : 617 - 617
  • [47] NONINVASIVE PH WITH TRANSCUTANEOUS PCO2 MONITORING AS AN ALTERNATIVE TO ARTERIAL LINE SAMPLING: A NEW PATIENT FRIENDLY APPROACH TO MONITORING ACUTE NIV
    Adejumo, I.
    Khan, J.
    Sovani, M.
    [J]. THORAX, 2015, 70 : A95 - A95
  • [48] Transcutaneous PCO2 monitoring in the evaluation of hyperventilation of patients with recurrent nerve paralysis
    Miyazaki, H
    Yamashita, P
    Masuda, T
    Yamamoto, T
    Komiyama, S
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 1999, 256 (Suppl 1) : S47 - S50
  • [49] Transcutaneous PCO2 monitoring in the evaluation of hyperventilation of patients with recurrent nerve paralysis
    H. Miyazaki
    H. Yamashita
    T. Masuda
    T. Yamamoto
    S. Komiyama
    [J]. European Archives of Oto-Rhino-Laryngology, 1999, 256 : S47 - S50
  • [50] Monitoring the patient-ventilator asynchrony during non-invasive ventilation
    Longhini, Federico
    Bruni, Andrea
    Garofalo, Eugenio
    Tutino, Simona
    Vetrugno, Luigi
    Navalesi, Paolo
    De Robertis, Edoardo
    Cammarota, Gianmaria
    [J]. FRONTIERS IN MEDICINE, 2023, 9