Audiometry in general practice - Validation of a pragmatic pure-tone audiometry method

被引:11
|
作者
Karlsmose, B
Pedersen, HB
Lauritzen, T
Parving, A
机构
[1] Aarhus Univ, Dept Gen Practice, DK-8000 Aarhus C, Denmark
[2] Aarhus Univ Hosp, ENT Dept, Aarhus, Denmark
[3] Bispebjerg Hosp, Dept Audiol, DK-2400 Copenhagen, Denmark
来源
SCANDINAVIAN AUDIOLOGY | 1998年 / 27卷 / 03期
关键词
Ebeltoft; family practice; hearing health services; pure-tone audiometry; reproducibility of results;
D O I
10.1080/010503998422638
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The aim of this study was to validate the results of diagnostic pure-tone audiometry performed in a typical practice setting by comparing with test results obtained in a standardized audiological setting in accordance with the ISO standards. In a single-blinded crossover design, 119 persons were tested (0.25-8 kHz) in both settings. The mean deviations as a function of frequency were in the order of less than 2 dB (0.5-4 kHz) and otherwise up to 4 dB; the practice setting representing the poorer thresholds. The validity of the practice audiometry at three criteria of hearing impairment (0.5-4 kHz) was characterized by sensitivity (82-100%), specificity (95-99%); positive predictive values (75-90%) and negative predictive values (98-100%) focusing on the better ear. It is concluded that pure-tone audiometry of appropriate validity can be performed in general practice and that it is useful in selecting patients with no need of further audiological examination. Guidelines are needed.
引用
收藏
页码:137 / 142
页数:6
相关论文
共 50 条
  • [21] QUANTIZATION-ERROR IN CLINICAL PURE-TONE AUDIOMETRY
    LEIJON, A
    SCANDINAVIAN AUDIOLOGY, 1992, 21 (02): : 103 - 108
  • [22] Tactile responses in pure-tone audiometry: a saccule function?
    Braun, Thomas
    Louza, Julia
    Guerkov, Robert
    Berghaus, Alexander
    Krause, Eike
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2013, 270 (09) : 2575 - 2575
  • [23] Development of a Deep Learning Model for Predicting Speech Audiometry Using Pure-Tone Audiometry Data
    Shin, Jae Sung
    Ma, Jun
    Choi, Seong Jun
    Kim, Sungyeup
    Hong, Min
    Applied Sciences (Switzerland), 2024, 14 (20):
  • [24] The Relevance of the High Frequency Audiometry in Tinnitus Patients with Normal Hearing in Conventional Pure-Tone Audiometry
    Vielsmeier, Veronika
    Lehner, Astrid
    Strutz, Juergen
    Steffens, Thomas
    Kreuzer, Peter M.
    Schecklmann, Martin
    Landgrebe, Michael
    Langguth, Berthold
    Kleinjung, Tobias
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [25] Evaluation of hearing with pure-tone audiometry in alopecia areata patients
    Erdogan, Hilal Kaya
    Acer, Ersoy
    Haklu, Ahmet
    Bulur, Isil
    Incesulu, Armagan
    Pinarbasli, Ozgur
    Bilgin, Muzaffer
    TURKDERM-TURKISH ARCHIVES OF DERMATOLOGY AND VENEROLOGY, 2019, 53 (01): : 19 - 23
  • [26] Pure-tone and speech audiometry in patients with Meniere's disease
    Mateijsen, DJM
    Van Hengel, PWJ
    Van Huffelen, WM
    Wit, HP
    Albers, FWJ
    CLINICAL OTOLARYNGOLOGY, 2001, 26 (05) : 379 - 387
  • [27] PURE TONE AUDIOMETRY
    HUIZING, HC
    ACTA OTO-LARYNGOLOGICA, 1951, 40 (1-2) : 51 - 61
  • [28] OTOLOGY AUDIOLOGY .5. CONDITIONED PURE-TONE AUDIOMETRY
    ROSE, WR
    VETERINARY MEDICINE & SMALL ANIMAL CLINICIAN, 1977, 72 (06): : 1090 - &
  • [29] OCCLUSION EFFECT IN BONE CONDUCTION PURE-TONE AND SPEECH AUDIOMETRY
    EDGERTON, BJ
    KLODD, DA
    JOURNAL OF THE AMERICAN AUDIOLOGY SOCIETY, 1977, 2 (04): : 151 - 158
  • [30] USE AND LIMITATIONS OF MASKING NOISE IN PURE-TONE AND SPEECH AUDIOMETRY
    LIDEN, G
    AUDIOLOGY, 1971, 10 (02): : 115 - +