The effects of isobaric and hyperbaric bupivacaine on maternal hemodynamic changes post spinal anesthesia for elective cesarean delivery: A prospective cohort study

被引:7
|
作者
Helill, Shamill Eanga [1 ]
Sahile, Wossenyeleh Admasu [2 ]
Abdo, Ritbano Ahmed [3 ]
Wolde, Getahun Dendir [4 ]
Halil, Hassen Mosa [3 ]
机构
[1] Wachemo Univ, Dept Anesthesia, Coll Med & Hlth Sci, Hossana, Ethiopia
[2] Addis Ababa Univ Addis, Sch Med, Dept Anesthesia, Addis Ababa, Ethiopia
[3] Wachemo Univ, Dept Midwifery, Coll Med & Hlth Sci, Hossana, Ethiopia
[4] Wolaita Sodo Univ, Sch Med, Dept Anesthesia, Wolaita, Ethiopia
来源
PLOS ONE | 2019年 / 14卷 / 12期
关键词
INTRATHECAL BUPIVACAINE; RISK-FACTORS; HYPOTENSION; BARICITY; SECTION; SPREAD;
D O I
10.1371/journal.pone.0226030
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Spinal anesthesia is a form of regional anesthesia frequently used in various lower abdominal, orthopedic, obstetric operations such as a cesarean delivery. The most common local anesthetic used for spinal anesthesia in obstetric and non-obstetric surgery is bupivacaine which can be utilized as an isobaric or hyperbaric solution, producing differences in maternal hemodynamic changes. Against this backdrop, the study aims to compare the effects of isobaric and hyperbaric bupivacaine on maternal hemodynamic alterations after administering spinal anesthesia for elective cesarean delivery at Gandhi Memorial Hospital, Addis Ababa, Ethiopia. Methods A hospital-based prospective cohort study design was employed for the period December 1, 2017 to January 30, 2018. A total of 100 parturient were involved, with one group exposed to isobaric bupivacaine and the other to hyperbaric bupivacaine to observe their effects on maternal hemodynamic changes post spinal anesthesia. The participants were selected through systematic random sampling. Data analysis was performed using SPSS (version 20) through descriptive statistic, independent sample t-test, Mann-Whitney U-test, Fisher's exact test, and Chi-square test were used. P values of < 0.05 was assumed as statistically significant for all tests. Results The incidence of hypotension was found to be greater in isobaric than hyperbaric groups (82% vs. 60% respectively; p = 0.015). No statistical significant differences were found in mean arterial pressure value at baseline, but, statistically significant changes were observed among the groups (p < 0.05) at all study timing after spinal anesthesia, except at 30th min. No statistically significant differences were seen in the mean heart rate variability after spinal anesthesia at all periods, except the 15th minute (p = 0.033). A greater rate of vasopressor was used in the isobaric group as compared to the hyperbaric group (36% vs. 14% respectively; p = 0.011). Conclusion Baricity is a significant factor in maternal hemodynamic changes in the parturient for elective cesarean section. Isobaric bupivacaine produces greater change in blood pressure and incidence of hypotension and entails a greater vasopressor requirement than hyperbaric bupivacaine after spinal anesthesia for elective cesarean section.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] A comparison of the effects of hyperbaric and isobaric bupivacaine spinal anesthesia on hemodynamics and heart rate variability
    Toptas, Mehmet
    Uzman, Sinan
    Isitemiz, Ilke
    Uludag Yanaral, Tumay
    Akkoc, Ibrahim
    Bican, Gulsen
    [J]. TURKISH JOURNAL OF MEDICAL SCIENCES, 2014, 44 (02) : 224 - 231
  • [22] INCREMENTAL SPINAL-ANESTHESIA FOR ELECTIVE CESAREAN-SECTION - MATERNAL AND FETAL HEMODYNAMIC-EFFECTS
    ROBSON, SC
    SAMSOON, G
    BOYS, RJ
    RODECK, C
    MORGAN, B
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1993, 70 (06) : 634 - 638
  • [23] Association Between Hyperbaric Bupivacaine Dose and Maternal Hypotension: Retrospective Database Study of 8226 Women Undergoing Cesarean Delivery Under Spinal Anesthesia
    Weiniger, Carolyn F.
    Heesen, Michael
    Knigin, David
    Deutsch, Frederic
    Hilber, Nicole
    Avidan, Alexander
    [J]. ANESTHESIA AND ANALGESIA, 2021, 133 (04): : 967 - 975
  • [24] Hemodynamic Effects of Ephedrine, Phenylephrine, and the Coadministration of Phenylephrine with Oxytocin during Spinal Anesthesia for Elective Cesarean Delivery
    Dyer, Robert A.
    Reed, Anthony R.
    van Dyk, Dominique
    Arcache, Michelle J.
    Hodges, Owen
    Lombard, Carl J.
    Greenwood, Jaime
    James, Michael F.
    [J]. ANESTHESIOLOGY, 2009, 111 (04) : 753 - 765
  • [25] Effectiveness of meperidine versus tramadol on post spinal anesthesia shivering in elective cesarean section: A prospective observational cohort study
    Tilahun, Abere
    Seifu, Ashenafi
    Aregawi, Adugna
    Abera, Bacha
    Demsie, DesalegnGetnet
    [J]. INTERNATIONAL JOURNAL OF SURGERY OPEN, 2021, 28 : 22 - 26
  • [26] Hemodynamic changes associated with spinal anesthesia for cesarean delivery in severe preeclampsia
    Dyer, Robert A.
    Piercy, Jenna L.
    Reed, Anthony P.
    Lombard, Carl J.
    Schoeman, Leann K.
    James, Michael F.
    [J]. ANESTHESIOLOGY, 2008, 108 (05) : 802 - 811
  • [27] Hemodynamic and analgesic effect of intrathecal fentanyl with bupivacaine in patients undergoing elective cesarean section; a prospective cohort study
    Ebrie, Ayub Mohammed
    Woldeyohanis, Misrak
    Abafita, Bedru Jemal
    Ali, Siraj Ahmed
    Zemedkun, Abebayehu
    Yimer, Yusuf
    Ashebir, Zewetir
    Mohammed, Salih
    [J]. PLOS ONE, 2022, 17 (07):
  • [28] Comparison of hemodynamic changes and fetal outcome between normotensive and preeclamptic parturient undergoing elective cesarean section under spinal anesthesia: A prospective observational cohort study
    Tamiru, Sintayehu Mulugeta
    Bantie, Abere Tilahun
    [J]. ANNALS OF MEDICINE AND SURGERY, 2022, 78
  • [29] A Randomized Comparison of Low Doses of Hyperbaric Bupivacaine in Combined Spinal-Epidural Anesthesia for Cesarean Delivery
    Leo, Serene
    Sng, Ban Leong
    Lim, Yvonne
    Sia, Alex T. H.
    [J]. ANESTHESIA AND ANALGESIA, 2009, 109 (05): : 1600 - 1605
  • [30] Spinal anesthesia with sequential administration of plain and hyperbaric bupivacaine provides satisfactory analgesia with hemodynamic stability in cesarean section
    Cesur, M.
    Alici, H. A.
    Erdem, A. F.
    Borekci, B.
    Silbir, F.
    [J]. INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2008, 17 (03) : 217 - 222