Ultrasonographic optic nerve sheath diameter as a noninvasive marker for intracranial hypotension

被引:7
|
作者
Li-juan Wang [1 ]
Zhang, Ying [1 ]
Li, Cong [1 ]
Liu, Ying [1 ]
Ya-nan Dong [1 ]
Cui, Li [1 ]
Ying-qi Xin [1 ,2 ,3 ]
机构
[1] Jilin Univ, Hosp 1, Neurosci Ctr, Dept Neurol, Xinmin St 71, Changchun 130021, Peoples R China
[2] Capital Med Univ, Xuanwu Hosp, Ctr Vasc Ultrasonog, Beijing Inst Brain Disorders, Beijing, Peoples R China
[3] Capital Med Univ, Xuanwu Hosp, Dept Vasc Ultrasonog, Beijing, Peoples R China
关键词
intracranial hypotension; invasive intracranial pressure; optic nerve sheath diameter; receiver operating characteristic; ultrasound; SUBARACHNOID SPACE; PRESSURE; PATIENT; INJURY;
D O I
10.1177/17562864211069744
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Invasive intracranial pressure (ICP) can result in complications, pain, or even aggravate intracranial hypotension (IH) or headache in patients with IH. Objective: To investigate whether ultrasonographic measurements of optic nerve sheath diameter (ONSD) could serve as a noninvasive IH marker. Methods: Ultrasonographic ONSD was measured prior to lumbar puncture (LP) and ONSD measurements compared to LP's opening pressure. We analyzed correlations between ONSD and ICP and determined the optimal ONSD cut-off point for IH. According to their LP on admission, patients were divided into three groups: IH group, normal ICP group, and elevated ICP group. Correlations between ONSD and ICP were analyzed using Pearson's correlation. A receiver operating characteristic (ROC) curve was generated to determine the optimal cut-off point for IH. Results: In total, 136 subjects (75 men, 55.1% men) were included, and 1088 ONSDs were measured. The ONSD of the IH group (2.96 +/- 0.15 mm) was significantly lower than that of the normal (3.59 +/- 0.33 mm) and elevated ICP groups (4.90 +/- 0.42 mm, p < 0.001). There was a significant difference in ONSD within all groups (p < 0.001), and the differences between the two groups were also statistically significant. ONSD and ICP values were strongly correlated, with an r = 0.952 (95% confidence interval [CI]: 0.924-0.969; p < 0.001). After adjusting for age, diastolic blood pressure, systolic blood pressure, body mass index, waistline, and head circumference, ONSD was positively associated with ICP. ROC curve analysis revealed an area under the curve of 0.990 (95% CI: 0.975-1.000). The ONSD cut-off point for identifying decreased opening pressure on LP was 3.15 mm, with 98.3% sensitivity and 91.7% specificity. Conclusions: Ultrasonographic ONSD may be a noninvasive, valuable, and easy-to-perform bedside technology for evaluating IH.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Optic nerve sheath diameter and intracranial pressure RESPONSE
    Driessen, Caroline
    [J]. JOURNAL OF NEUROSURGERY-PEDIATRICS, 2012, 9 (05) : 571 - 571
  • [22] Transorbital Ultrasonographic Measurement of the Optic Nerve Sheath Diameter in Preeclampsia
    Ferro, Felipe
    Rocha, Edilberto
    Nobrega, Leandro
    Amorim, Melania M.
    Katz, Leila
    [J]. OBSTETRICS AND GYNECOLOGY, 2016, 127 : 87S - 87S
  • [23] Correlation of optic nerve and optic nerve sheath diameter with intracranial pressure in pigs
    Mija, R.
    Zubak, I
    Schuetz, A.
    Glas, M.
    Fung, C.
    Jakob, S. M.
    Beck, J.
    Z'Graggen, W. J.
    Bloch, Andreas
    [J]. PLOS ONE, 2020, 15 (02):
  • [24] The measurement of ultrasonographic optic nerve sheath diameter in patients with hyperglycemia
    Donertas, Eda
    Kozaci, Nalan
    Avci, Mustafa
    [J]. HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2022, 29 (03) : 137 - 143
  • [25] Optic nerve sheath diameter as ICP marker Response
    Maissan, Iscander M.
    Haitsma, Lain K.
    Stolker, Robert Jan
    [J]. JOURNAL OF NEUROSURGERY, 2016, 124 (03) : 891 - 891
  • [26] Transorbital Ultrasonographic Measurement of Optic Nerve Sheath Diameter for Intracranial Midline Shift in Patients with Head Trauma
    Kazdal, Hizir
    Kanat, Ayhan
    Findik, Huseyin
    Sen, Ahmet
    Ozdemir, Bulent
    Batcik, Osman Ersegun
    Yavasi, Ozcan
    Inecikli, Mehmet Fatih
    [J]. WORLD NEUROSURGERY, 2016, 85 : 292 - 297
  • [27] Correlation of the transorbital ultrasonographic optic nerve sheath diameter with intracranial pressure measured intraoperatively in infants with hydrocephalus
    Okpara, Samuel E.
    Uche, Enoch O.
    Iloanusi, Nneka I.
    Iloabachie, Izuchukwu C.
    Mezue, Wilfred C.
    Onyia, Ephraim E.
    Chikani, Mark C.
    Mathew, Mesi
    [J]. JOURNAL OF NEUROSURGERY-PEDIATRICS, 2024, 33 (04) : 334 - 342
  • [28] Ultrasonographic optic nerve sheath diameter measurement in overweight parturient with intracranial tumour: Guiding choice of anaesthesia
    Riaz, Rameez
    Khuba, Sandeep
    Shamim, Rafat
    Patro, Abinash
    [J]. INDIAN JOURNAL OF ANAESTHESIA, 2016, 60 (10) : 775 - U132
  • [29] Correlation Between Ultrasonographic Optic Nerve Sheath Diameter and Intracranial Pressure in Patients with Aneurysmal Subarachnoid Hemorrhage
    Suresh, Varun
    Sharma, Saurabh
    Aggarwal, Anurag
    [J]. NEUROCRITICAL CARE, 2020, 33 (03) : 860 - 861
  • [30] Correlation Between Ultrasonographic Optic Nerve Sheath Diameter and Intracranial Pressure in Patients with Aneurysmal Subarachnoid Hemorrhage
    Varun Suresh
    Saurabh Sharma
    Anurag Aggarwal
    [J]. Neurocritical Care, 2020, 33 : 860 - 861