Performance evaluation of a compact PET/SPECT/CT tri-modality system for small animal imaging applications

被引:11
|
作者
Wei, Qingyang [1 ,3 ]
Wang, Shi [2 ,3 ]
Ma, Tianyu [2 ,3 ]
Wu, Jing [2 ,3 ]
Liu, Hui [2 ,3 ]
Xu, Tianpeng [2 ,3 ]
Xia, Yan [2 ,3 ]
Fan, Peng [2 ,3 ]
Lyu, Zhenlei [2 ,3 ]
Liu, Yaqiang [2 ,3 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Key Lab Particle & Radiat Imaging, Minist Educ, Beijing 100084, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Animal PET/SPECT/CT; Molecular imaging; Instrumentation; Performance evaluation; DETECTOR;
D O I
10.1016/j.nima.2015.03.045
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
PET, SPEcT and CT imaging techniques are widely used in preclinical small animal imaging applications. In this paper, we present a compact small animal PET/SPECT/CT tri-modality system. A dual-functional, shared detector design is implemented which enables PET and SPECT imaging with a same LYSO ring detector. A multi-pinhole collimator is mounted on the system and inserted into the detector ring in SPECT imaging mode. A cone beam CT consisting of a micro focus X-ray tube and a CMOS detector is implemented. The detailed design and the performance evaluations are reported in this paper. In PET imaging mode, the measured NEMA based spatial resolution is 2.12 mm (FWHM), and the sensitivity at the central field of view (CFOV)is 3.2%. The FOV size is 50 mm (circle divide) x 100 mm (L). The SPECT has a spatial resolution of 1.32 mm (FWHM) and an average sensitivity of 0.031% at the center axial, and a 30 mm (circle divide) x 90 mm (L) FOV. The CT spatial resolution is 8.32 lp/rnm @10%WTF, and the contrast discrimination function value is 2.06% with 1.5 mm size cubic box object. In conclusion, a compact, Lri-modaliLy PET/SPECT/CT system was successfully built with low cost and high performance. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:147 / 154
页数:8
相关论文
共 50 条
  • [21] Intravascular tri-modality system: Combined ultrasound, photoacoustic, and elasticity imaging
    Wang, Pingping
    Chen, Zhongjiang
    Yang, Fen
    Yang, Sihua
    Xing, Da
    APPLIED PHYSICS LETTERS, 2018, 113 (25)
  • [22] Tri-modality Ultrasound Imaging System: Design and Phantom Experiment Results
    Nguyen, Man M.
    Ding, Xuan
    Yu, Jaesok
    Park, Daewoo
    Yu, Francois
    Kim, Kang
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 325 - 328
  • [23] State-of-the-art of PET, SPECT and CT for small animal imaging
    Del Guerra, Alberto
    Belcari, Nicola
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 583 (01): : 119 - 124
  • [24] A SMALL ANIMAL SYSTEM CAPABLE OF PET, SPECT AND PLANAR IMAGING
    GREEN, MV
    SEIDEL, J
    GANDLER, WR
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P61 - P61
  • [25] Initial Evaluation of LabPET/SPECT Dual Modality Animal Imaging System
    Yao, Rutao
    Deng, Xiao
    Beaudoin, Jean-Francois
    Ma, Tianyu
    Cadorette, Jules
    Cao, Zixiong
    Lecomte, Roger
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (01) : 76 - 81
  • [26] A compact CT/SPECT system for small-object imaging
    Zingerman, Y.
    Golan, H.
    Gersten, A.
    Moalem, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 584 (01): : 135 - 148
  • [27] Quantitative SPECT/CT: SPECT joins PET as a quantitative imaging modality
    Dale L. Bailey
    Kathy P. Willowson
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 17 - 25
  • [28] Quantitative SPECT/CT: SPECT joins PET as a quantitative imaging modality
    Bailey, Dale L.
    Willowson, Kathy P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S17 - S25
  • [29] PET/SPECT/CT imaging with a single animal
    Zhang, JoAnn
    Iwata, Koji
    Wei, David Tan Tat
    Wei, Gloira
    Wangand, Hsin-Ell
    Liu, Ren-Shyan
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [30] Integrated CT-SPECT system for small animal imaging
    Williams, MB
    Zhang, GM
    More, MJ
    Goode, AR
    Majewski, S
    Wojcik, R
    Kross, B
    Popov, V
    Weisenberger, AG
    Stanton, M
    Phillips, W
    Stewart, A
    McCauley, T
    Wu, T
    DiBella, EVR
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS II, 2000, 4142 : 265 - 274