Dynamics and control of solution levels in a high temperature generator for an absorption chiller

被引:16
|
作者
Seo, Jeong Ah [1 ]
Shin, Younggy [1 ]
Chung, Jae Dong [1 ]
机构
[1] Sejong Univ, Dept Mech Engn, Seoul 143747, South Korea
关键词
Absorber; Absorption system; Control; Inverter; Level controller; Pump;
D O I
10.1016/j.ijrefrig.2012.01.020
中图分类号
O414.1 [热力学];
学科分类号
摘要
It is desired to keep the level of a high temperature generator (HTG) solution constant for the purpose of linear controllability and solution economy. Level switches are used to control the solution level. The control of the solution level requires a good flow rate prediction model. It is found that the model can be approximated as a function of HTG solution temperature and coolant inlet temperature. This study identified two aspects of the control strategy for a solution pump inverter that are practiced in the industry. (1) A cut-off frequency of 27 Hz is set up to supply more solution than expected at low HTG temperatures against any possible depletion of solution and (2) at high HTG temperatures, the sensitivity of the inverter frequency to the cooling water inlet temperature is set to a minimum to reduce solution level fluctuations. This study suggests an improved control algorithm that is proven to have high control performance. (C) 2012 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:1123 / 1129
页数:7
相关论文
共 50 条
  • [21] Experimental Study of Process Chiller for Semiconductor Temperature Control
    Cha, Dong An
    Kwon, Oh Kyung
    Oh, Myung Do
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2011, 35 (05) : 459 - 465
  • [22] Effect of Tube Arrangement on the Thermal Performance of a High Temperature Generator of the Absorption System
    Lee, Insong
    Cho, Keumnam
    JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2009, 4 (03): : 340 - 349
  • [23] The development of a dynamic single effect, lithium bromide absorption chiller model with enhanced generator fidelity
    Misenheimer, Corey T.
    Terry, Stephen D.
    ENERGY CONVERSION AND MANAGEMENT, 2017, 150 : 574 - 587
  • [24] Study of the thermosiphon solution elevation tubes with lunate channel in solar absorption chiller
    Zheng, Hongfei
    Wu, Yuyuan
    Jiang, Hua
    Zhang, Jing
    Zhang, Lianying
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2003, 24 (04): : 466 - 471
  • [25] Performance improvement of NH3-H2O absorption chiller with a combined generator
    Wirtz, Mathilde
    Stutz, Benoit
    Phan, Hai Trieu
    Boudehenn, Francois
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 144 : 331 - 341
  • [26] Simulation and optimization of direct-fired absorption chiller system with an exhaust heat recovery generator
    Wang, Leilei
    You, Shijun
    Sun, Hejiang
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2008, 36 (06): : 125 - 128
  • [27] Heat transfer characteristics of a falling film generator for various configurations of heating tubes in an absorption chiller
    Lee, Joon Ha
    Kim, Dae Hae
    Kim, Seong Min
    Kim, Min Soo
    Kim, In Gwan
    Woo, Sung Min
    Hong, Sung Joo
    Park, Chan Woo
    APPLIED THERMAL ENGINEERING, 2019, 148 : 1407 - 1415
  • [28] Solar cooling with the absorption principle: First and Second Law analysis of an ammonia-water double-generator absorption chiller
    Ben Ezzine, N.
    Barhourni, M.
    Mejbri, Kh.
    Chemkhi, S.
    Bellagi, A.
    DESALINATION, 2004, 168 (1-3) : 137 - 144
  • [29] Development and operation of a high performance 10kw absorption chiller
    Lorton, R
    Gilchrist, K
    Green, RJ
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2000, 23 (08): : 572 - 576
  • [30] Modeling an integral dual solar/gas fired generator for a water-lithium bromide absorption chiller
    Department of Mechanical Engineering, Ohio State University, Columbus, OH 43210, United States
    ASME Adv Energy Syst Div Publ AES, (159-165):