Dynamics and control of solution levels in a high temperature generator for an absorption chiller

被引:16
|
作者
Seo, Jeong Ah [1 ]
Shin, Younggy [1 ]
Chung, Jae Dong [1 ]
机构
[1] Sejong Univ, Dept Mech Engn, Seoul 143747, South Korea
关键词
Absorber; Absorption system; Control; Inverter; Level controller; Pump;
D O I
10.1016/j.ijrefrig.2012.01.020
中图分类号
O414.1 [热力学];
学科分类号
摘要
It is desired to keep the level of a high temperature generator (HTG) solution constant for the purpose of linear controllability and solution economy. Level switches are used to control the solution level. The control of the solution level requires a good flow rate prediction model. It is found that the model can be approximated as a function of HTG solution temperature and coolant inlet temperature. This study identified two aspects of the control strategy for a solution pump inverter that are practiced in the industry. (1) A cut-off frequency of 27 Hz is set up to supply more solution than expected at low HTG temperatures against any possible depletion of solution and (2) at high HTG temperatures, the sensitivity of the inverter frequency to the cooling water inlet temperature is set to a minimum to reduce solution level fluctuations. This study suggests an improved control algorithm that is proven to have high control performance. (C) 2012 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:1123 / 1129
页数:7
相关论文
共 50 条
  • [1] Experimental research of a novel vortex generator for solar absorption chiller
    Yan Wang
    Jian Yu
    ChongFang Ma
    Science in China Series E: Technological Sciences, 2009, 52 : 1793 - 1798
  • [2] Performance of a dual-chamber vortex generator for absorption chiller
    Yu, J
    Ogut, A
    Zhou, Y
    2ND ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, PROCEEDINGS: NEW CONTRIBUTION TO ASIAN SUSTAINABLE DEVELOPMENT, 2004, : 432 - 440
  • [3] Experimental research of a novel vortex generator for solar absorption chiller
    Wang Yan
    Yu Jian
    Ma ChongFang
    SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 2009, 52 (06): : 1793 - 1798
  • [5] Theoretical Studies on Start-up Characteristics of a High-pressure Generator for LiBr Absorption Chiller
    Xiang, Liping
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 1574 - 1577
  • [6] Thermodynamic modelling of a two-stage absorption chiller driven at two-temperature levels
    Figueredo, Gustavo R.
    Bourouis, Mahmoud
    Coronas, Alberto
    APPLIED THERMAL ENGINEERING, 2008, 28 (2-3) : 211 - 217
  • [7] Irreversibilities in two configurations of the double generator absorption chiller - Comparison of performance
    Ben Ezzine, N
    Barhoumi, M
    Mejbri, K
    Bellagi, A
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2005, 80 (02) : 471 - 475
  • [8] Hybrid solar receiver as a source of high-temperature medium for an absorption chiller supply
    Przenzak, Estera
    Filipowicz, Mariusz
    EFM15 - EXPERIMENTAL FLUID MECHANICS 2015, 2016, 114
  • [9] A residential absorption chiller for high ambient temperatures
    Kini, Girish
    Chandrasekaran, Sriram
    Tambasco, Michael
    Garimella, Srinivas
    International Journal of Refrigeration, 2020, 120 : 31 - 38
  • [10] Advantages of variable driving temperature in solar absorption chiller
    Petela, Karolina
    Manfrida, Giampaolo
    Szlek, Andrzej
    RENEWABLE ENERGY, 2017, 114 : 716 - 724